Page 1

1 2923844.3 116173-101909 ZB-21-21 Daughters of Israel, Inc. 1155 Pleasant Valley Way West Orange, New Jersey Block 171, Lot 12 List of Variances Required Application Form, Section D. – Type of Application Site Plan/Subdivision Checklist #24 Revised January 30, 2023 [Changes to the plans submitted in November 2022 are identified in bold underlined text] “d” Variances SECTION DESCRIPTION REQUIRED/PERMITTED EXISTING PROPOSED § 25-7.1 Permitted Principal Uses Single-family dwellings, hospital, government buildings, farm, nursery Nursing home Continuing Care Retirement Community (CCRC) [a continuum of care facility including independent living, assisted living and skilled nursing components, together with accessory uses] § 25-7.1 Maximum height 2½ stories / 35 feet 2 stories 5 stories / 57.77 feet § 25-8.12 Number of principal uses on a lot 1 1 (nursing home) 3 (if component uses are characterized individually)

Page 2

2 2923844.3 116173-101909 “c” Variances SECTION DESCRIPTION REQUIRED/PERMITTED EXISTING PROPOSED § 25-7.1 Maximum lot coverage 30% 38.53% 37.25% § 25-8.4 Maximum height of retaining wall 4’ 4’ 10’ § 25-12.1.o. Maximum length of continuous parking row without landscaped island 20 spaces >20 spaces 22 spaces (southeast perimeter of parking lot) § 25-12.2 Number of parking spaces 448 (project total) 236 381 (includes 34 banked spaces) (426 with EV credit) § 25-12.3.a.2. Number of loading spaces 13 2 1 § 25-12.4.a.6. Parking of vehicle with dual rear wheels Not permitted Parking of existing shuttle bus Parking of the same or similar shuttle bus § 25-12.4.b.3. Parking of commercial vehicles In garage, or if too large, outdoors with commercial markings removed; single axle; maximum 20’ long, 7’ high and 6,000 gross vehicle weight Parking of existing shuttle bus and several delivery vans outdoors, with commercial markings, some having a double axle and/or exceeding size limit Parking of the same or similar shuttle bus and several delivery vans outdoors, with commercial markings, some having a double axle and/or exceeding size limit

Page 3

3 2923844.3 116173-101909 SECTION DESCRIPTION REQUIRED/PERMITTED EXISTING PROPOSED § 25-14.1.c. Light pole height 18’ >18’ 25’ § 25-14.4.a. Number of signs per linear feet of frontage 8 (4 signs per 250’; 648’ of frontage) 1 11 § 25-15.3 Sign illumination Illumination not expressly permitted in R-2 District Externally illuminated with ground-mounted light fixture Freestanding signs: Externally illuminated with ground-mounted light fixture Building signs: Reverse lit channel letters § 25-15.3.b. Number of signs per lot 1 1 monument sign 5 facade signs 1 monument sign (existing) 1 freestanding identification sign (health center) 4 freestanding directional signs § 25-15.3.b. Maximum sign area 1 s.f. for a nameplate 2 s.f. for a professional office 56 s.f. monument sign (variance granted under Case #ZB-11-06) Ranges from 8.75 s.f. to 56 s.f.

Page 4

4 2923844.3 116173-101909 SECTION DESCRIPTION REQUIRED/PERMITTED EXISTING PROPOSED § 25-28.8.d.; § 25-7.1-Table Maximum effective building coverage 20% 26.15% 24.86% § 25-28.8.d. § 25-7.1-Table Maximum effective impervious coverage 30% 61.19% 59.48%