Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Jul 16, 2024

Engineering Plans 2

Preserved file SHA-25678e67d8702cd1286ec7092d9543ab17ac49b1c46dc2739346299eaa41502e3b3

Indexed text

Page 9

4.0' P.S. R15.0' 9.0' . TYP R5.0' 34 .7' .0 18 24 . 0' Scale AS SHOWN PWA 18.0' Checked by 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com Anderson Consulting Services LLC 24.0' PWA 18.0' 4.3' Designed by R49.0' R5. 0' SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 PAUL W. ANDERSON WALL (TYP.) BCA SIDEWALK .2 0' 18. P. Y T ING D 4.0 BUILD R4 .5' WALL (TYP.) R6.0 ' 0' Drawn by 9.0 TY ' P. 9.0 ' TY P. 24. Date Proj. No. WALL (TYP.) R5.0' ' 9.0 4 R PRELIMINARY AND FINAL SITE PLAN ALK EW SID Call before you dig. R15.0' R5.0' ' 24.0 Know what's below. 4.0' LK WA E SID MATCHLINE SP-8 R ' R5.0 MATCHLINE SP-8 22 .0' MATCHLINE SP-10 MATCHLINE SP-10 R5.0' R64.0' ' W IDE K AL 0' 24. S R6. 0' ' SP-9 SHEET 9 OF 66

Page 10

9 R4 .0' 24. 0' WALL (TYP.) R49.0' R5.0' R64.0' ' 4.0 AL S 0' 18. P. TY W IDE K 0' 24. PWA Checked by 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com Anderson Consulting Services LLC 24.0 AS SHOWN PWA Designed by MATCHLINE Scale BCA R5.0' Drawn by SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 PAUL W. ANDERSON 18.0' TYP. Date 18.0' TYP. Proj. No. .1' D.1 R5 ING Call before you dig. 16.0' PRELIMINARY AND FINAL SITE PLAN ILD BU MATCHLINE SP-9 24.0' ' Know what's below. 5.5' ALK R5.0 R SIDEW ' WALL (TYP.) MATCHLINE SP-9 R6.0 SS ACCE ENCY 0' G EMER R5. MATCHLINE 16.0' R2 5.0 ' 4.0' SIDEW ALK 16.0' SP-10 SHEET 10 OF 66

Page 11

602 GE EMER 604 CE NCY AC 606 SS 608 610 612 61 2 610 608 612 61 8 61 62 0 622 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. HOWELL DRIVE 600 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 PAUL W. ANDERSON SLAYBACK TERRACE HOWELL DRIVE 0 61 6 61 4 606 608 606 606 61 0 606 60 8 60 6 604 4 C BU ILD IN G 584 600 586 59 8 588 59 6 2 60 59 4 59 2 590 60 60 2 612 ST 582 ST ST 580 ST ST ST 602 ST BU ST ST IN 61 ST G ST GF:602.5 B 8 60 ST ST ST 60 0 ST ST ST 602 606 ST LOBBY ST ST ST 582 ST DIN 604 ST PACKING ROOM ST GD MAIL IL BU 602 ST 580 ST ST .1 ST 602 ST ST ST ST ST ST ST 8 ST FF:618.0 GF:606.0 59 59 8 59 8 ST B BUILDING 600 600 ST ST COMP. 59 9 G 5 F: 6 0 2. 59 4 FF: C614.2 BUILDING GF:602.5 59 6 59 4 59 2 584 598 59 59 58 0 59 59 6 0 0 59 4 59 59 2 2 59 594 0 59 59 6 59 4 592 FF:595.0 BF:582.0 592 POOL 582.5 CLUBHOUSE 590 590 584 576 582 584 586 586 590 58 6 580 4 592 578 58 2 57 2 576 580 FF:618.0 GF:592.5 568 56 59 564 2 56 576 574 0 4 564 560 G D.2 570 8 602 58 57 570 0 0 57 6 600 58 8 598 55 4 568 574 57 6 6 56 568 57 4 2 0 57 57 56 6 6 58 56 4 582 56 2 594 590 582 P.S. 560 592 572 570 588 8 596 4 582 58 56 558 574 56 6 580 4 562 560 562 586 576 562 578 564 4 58 582 572 570 6 562 566 56 56 560 558 6 58 8 564 554 0 56 556 55 568 56 IVE 568 572 566 556 562 6 57 4 57 2 57 572 574 0 606 604 576 57 612 610 608 DR 6 56 566 P.S. 56 0 616 614 BUILD IN 4 57 576 8 56 572 566 572 0 57 A.1 BUILDING FF:597.0 GF: 577.0 584 558 IR 556 554 562 8 556 554 55 552 560 FF:558.5 558 Anderson Consulting Services LLC 4 FA MAY FF:558.5 55 550 55 2 556 550 550 548 DOG PARK 554 548 54 546 8 552 546 544 55 2 550 55 2 BASIN 2-1 0 542 0 544 55 55 540 54 6 550 54 8 BASIN 2-2 54 4 542 548 540 53 4 538 E RACE Y TER R DRIV PRELIMINARY AND FINAL SITE PLAN FT L AN E FOWLE LU KUZIK DRIVE 4 53 BAKEL 534 BAYOWSKI ROAD 536 538 536 LAPIS CIRCLE UNDISTURBED / PRESERVED: 4,010,981.8 SF 92.08 Acres DISTURBED: 1,234,888.2 SF 28.35 Acres TOTAL IMPERVIOUS: 619,951.3 SF 14.23 Acres R Know what's below. Call before you

Page 11

38 536 LAPIS CIRCLE UNDISTURBED / PRESERVED: 4,010,981.8 SF 92.08 Acres DISTURBED: 1,234,888.2 SF 28.35 Acres TOTAL IMPERVIOUS: 619,951.3 SF 14.23 Acres R Know what's below. Call before you dig. PWA 540 540 Checked by 542 53 2 8 53 2 PWA 536 534 540 538 53 Date Proj. No. 54 6 532 2 Designed by BASIN 2-6 4 54 54 BCA 544 53 534 Drawn by 546 BASIN 2-5 544 542 53 2 WARNE R 546 544 536 546 542 546 540 542 546 544 542 BASIN 2-4 53 0 ROAD 538 544 8 53 6 54 8 52 8 HOLTON LANE BASIN 2-3 AS SHOWN 576 58 574 580 578 588 594 588 580 Scale 596 582 592 594 6 59 584 592 590 588 586 584 582 578 0 8 6 586 594 588 58 58 BUILDING A.2 FF:597.0 GF: 577.0 4 57 57 590 586 2 588 0 59 6 592 594 59 580 592 588 596 570 598 58 596 2 58 6 FF:602.5 GF:590.5 FF:618.0 GF:597.0 582 2 592 M. 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com 578 ROSEMONT TERRACE D IL 0 ST 602 MOTOR VEHICLE SURFACE AREA: 257,012 SF 5.84 Acres SP-11 SHEET 11 OF 66

Page 12

622 6 61 4 612.0 + 61 0 60 8 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. 62 0 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 61 8 PAUL W. ANDERSON 61 612 60 6 + 613.0 60 59 589.9 2 590 4 C IN G ILD 612 ST 582 BU 584 600 586 59 8 588 59 6 2 59 60 4 + ST ST 580 ST 602 ST ST + 579.5 ST D IL BU ST + 601.0 IN 61 + 610.5 ST B GF:602.5 601.0 + 0 ST ST 602 G 578 ST 8 60 ST ST ST ST ST ST 602 606 ST LOBBY ST ST ST ST 602 ST + 586.0 ST ST ST ST TW:602.0 BW:598.5 ST ST ST ST 59 8 59 8 ST ST BUILDING 600 600 ST COMP. ST 59 6 0 2. G 59 4 TW:599.0 BW:597.5 59 6 59 59 2 59 0 59 6 59 4 59 59 2 0 + 587.0 59 0 594.16 594.5 + FF:595.0 BF:582.0 592 CLUBHOUSE 590 580 TW: 589.0 BW: 586.0 584 TW: 584.0 BW: 578.0 588 TW: 585.0 BW: 578.0 6 58 57 582 4 580 58 578 2 58 584 580 6 586 578 588 0 592 574 59 6 592 586 594 588 8 6 590 57 59 590 594 BUILDING A.2 FF:597.0 GF: 577.0 594.34 + TW: 592.0 BW: 592.0 58 TW: 585.0 BW: 584.0 592 6 594 59 596 + 590 576 Call before you dig. 594.0 586 Know what's below. 592 594 590 588 586 580 2 57 MATCHLINE SP-13 58 594.0 + 582 592 + 59 586 584 582 580 578 576 4 57 583.75 + 588 584 588 + 596.5 6 R 594 2 59 + 595.0 58 2 PWA 0 598 596 Checked by 59 + 598.0 Date 600.0 Proj. No. FF:602.5 5 GF:590. + PRELIMINARY AND FINAL SITE PLAN M. PWA 59 6 Designed by 2 + 593.9 592 4 BCA 584 598 TC:597.5 BC:597.0 Drawn by B :614.2 F F C G BUILDINGF:602.5 Anderson Consulting Services LLC 9 5 F: AS SHOWN 582 ST MAIL + 603.9 Scale 604 ST PACKING ROOM 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com 602 ST 580 ST TW: 582.0 BW: 577.5 TW: 582.0 BW: 576.0 TW: 578.0 BW: 573.5 MATCHLINE SP-13 + SP-12 SHEET 12 OF 66

Page 13

MATCHLINE SP-12 582 590 588 594 582 596 + 584 TW: 584.0 BW: 578.0 57 6 582 584 586 586 590 580 578 580 576 578 BUILDING A.2 FF:597.0 GF: 577.0 574 6 592 594 59 5 84 6 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. 59 6 592 592 58 TW: 585.0 BW: 584.0 586 594 588 590 588 586 584 594.0 583.75 + 4 57 576 8 56 + + 576.0 570.0 4 576 580 2 57 0 57 A.1 BUILDING FF:597.0 GF: 577.0 57 57 0 0 59 590 592 594 586 58 8 578 592 59 6 58 2 588 580 588 + 596 0 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 59 596.5 PAUL W. ANDERSON + 587.0 2 2 59 + 595.0 59 MATCHLINE SP-12 6 570 56 56 4 2 56 576 574 560 + 570.0 6 57 + 572.5 574 57 0 566 556 568 572 8 55 56 6 562 56 8 562 560 562 558 BCA PWA PWA Designed by Checked by Date 558 Proj. No. 56 2 56 4 560 Drawn by 56 6 6 564 56 4 560 558 556 55 Anderson Consulting Services LLC 6 57 2 56 57 57 0 57 4 564 554 0 + 563.0 AS SHOWN 57 0 572 576 Scale 2 0 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com + 56 4 57 57 564.0 FF:558.5 55 4 554 562 556 554 55 8 552 560 FF:558.5 558 550 55 2 556 550 550 548 554 548 R Know what's below. Call before you dig. 544 2 -1 BASIN 2 MATCHLINE SP-14 546 55 MATCHLINE SP-14 550 TW: 548.0 BW: 546.0 546 TW: 548.0 BW: 546.0 2 8 54 552 55 DOG PARK PRELIMINARY AND FINAL SITE PLAN 556 SP-13 SHEET 13 OF 66

Page 14

4 562 8 556 554 55 560 FF:558.5 558 55 2 556 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 FF:558.5 55 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. MATCHLINE SP-13 PAUL W. ANDERSON MATCHLINE SP-13 550 DOG PARK 554 8 54 552 TW: 548.0 BW: 546.0 550 TW: 548.0 BW: 546.0 -1 BASIN 2 TW: 548.0 BW: 546.0 + 546.0 55 0 BASIN 2-2 + 546.0 550 TW: 546.0 BW: 542.0 TW: 548.0 BW: 546.0 BW: 542.0 + 542.0 + 540.5 + 542.0 + 542.0 542.0 + TW: 546.0 BW: 542.0 TW: 546.0 BW: 542.0 BASIN 2-3 + 542.0 + 542.0 548 + 542.0 + 542.0 54 8 BASIN 2-4 + 542.0 + 542.0 TW: 546.0 BW: 542.0 546 542 542.0 + TW: 546.0 BW: 542.0 TW: 546.0 BW: 542.0 BW: 540.5 546 + 542.0 BASIN 2-5 + 540.5 + 540.5 TW: 544.0 BW: 540.5 544 + 540.5 Anderson Consulting Services LLC 544 546 546 544 542 540 + 542.0 TW: 544.0 BW: 540.5 + 540.5 544 540.5 + 542 + 540.5 8 53 + 534.7 538 540 538 536 534 Know what's below. Call before you dig. 4 53 ZIK DRIVE R PRELIMINARY AND FINAL SITE PLAN 538 SP-14 SHEET 14 OF 66 NE 540 536 2 PWA TW: 544.0 BW: 540.5 Date TW: 544.0 BW: 540.5 Proj. No. 540 + 540.5 53 Checked by 542 53 2 54 PWA 2 536 534 + 534.7 Designed by 5 + 534.9 + 540.5 BCA TW: 546.0 BW: 542.0 BW: 540.5 44 Drawn by 54 6 + 540.5 + 540.5 BASIN 2-6 AS SHOWN TW: 546.0 BW: 542.0 Scale 544 542 546 + 542.0 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com 542.0 +

Page 15

MATCHLINE ST 8 8 ST 59 6 .0 2 9 5 F: G 556 59 TW:599.0 BW:597.5 4 59 6 554 59 2 552 TW: 595.0 BW: 594.0 59 2 + 593.9 592 TC:597.5 BC:597.0 59 4 59 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. 558 59 59 ST MATCHLINE SP-16 TW:602.0 BW:598.5 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 560 PAUL W. ANDERSON 602 6 TW: 594.0 BW: 594.0 59 TW: 594.0 BW: 588.0 0 59 0 550 59 2 2 0 588 548 + 584 582 8 54 580 584 86 580 5 TW:582.0 BW:574.5 TW: 585.0 BW: 578.0 TW:575.5 BW:573.9 4 58 TW: 582.0 BW: 575.0 TW:575.0 BW:569.0 58 TW: 582.0 BW: 576.0 TW: 582.0 BW: 577.5 TW: 575.0 BW: 571.0 6 TW: 578.0 BW: 573.5 576 53 TW:582.0 BW:575.5 2 574 578 2 + 53 4 TW: 576.0 BW: 572.3 TW: 577.2 BW: 573.2 TW:570.0 BW:570.0 568 2 + TC: 572.7 BC: 572.2 + 571.82 571.37 + + TC: 571.8 BC: 571.3 TC: 571.85 BC: 571.35 P.S. Anderson Consulting Services LLC 57 8 52 WARNE R 572 4 + 576.0 566 53 0 53 566 + 564 564 + 571.05 PWA Checked by 562 TC: 571.12 BC: 570.62 PWA TC: 571.22 BC: 570.72 + 572.5 + Designed by + BCA 534 Drawn by ROAD TW:575.0 BW:575.0 TW:582.0 BW:576.5 580 536 TW:582.0 BW:576.5 588 582 584 538 CLUBHOUSE TW: 589.0 BW: 586.0 TW: 584.0 BW: 578.0 57 6 54 4 586 8 53 TW: 582.0 BW: 578.0 POOL 582.5 578 588 54 6 590 54 0 FF:595.0 BF:582.0 592 590 540 542 TW: 582.0 BW: 582.0 + 56 Proj. No. 568 8 6 564 56 4 562 560 562 558 560 MATCHLINE SP-16 566 56 PRELIMINARY AND FINAL SITE PLAN 0 57 570 532 Date + 570.38 572 AS SHOWN 55 2 55 0 544 594.5 Scale 2 55 586 542 592 58 6 TW: 585.0 BW: 584.0 594.16 TW: 587.5 BW: 582.0 TW: 592.0 BW: 592.0 58 8 588 544 594.34 + + 0 590 546 59 546 594.0 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com 59 570 548 TW: 588.0 BW: 588.0 57 550 594 59 TW: 587.5 BW: 582.0 558 MATCHLINE R Know what's below. Call before you dig. SP-15 SHEET 15 OF 66

Page 16

TW: 587.5 BW: 582.0 596 2 58 TW: 594.0 BW: 588.0 FF:618.0 GF:597.0 582 580.2 + 596.8 + 58 0 TW:590.0 BW:584.0 580.2 + TW:595.0 BW:589.0 TW:588.0 BW:582.0 TW: 588.0 BW: 588.0 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 MATCHLINE SP-15 TW: 594.0 BW: 594.0 TW:596.5 BW:590.5 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. MATCHLINE SP-17 PAUL W. ANDERSON MATCHLINE SP-17 TW: 587.5 BW: 582.0 59 4 TW: 582.0 BW: 582.0 TW:586.5 BW:580.5 TW: 582.0 BW: 578.0 POOL 582.5 TW:582.0 BW:576.5 TW:594.5 BW:587.5 TW:575.0 BW:575.0 TW:582.0 BW:576.5 TW:582.0 BW:574.5 TW:592.0 BW:588.5 TW:582.0 BW:575.5 TW:574.0 BW:571.0 592 TW:588.0 BW:584.0 617.0 + 591.5 + FF:618.0 GF:592.5 616 566 568 TW:592.0 BW:586.0 614 .2 566 ING D 564 610 608 BUILD 0 59 564 612 + 571.00 TW:590.0 BW:586.0 606 604 8 602 58 Anderson Consulting Services LLC 562 TW:588.0 BW:584.0 TW:586.0 BW:583.0 + 571.00 BCA PWA PWA Designed by Checked by 598 Drawn by 6 600 58 58 4 596 594 4 568 56 6 592 590 588 582 58 6 MATCHLINE SP-15 584 PRELIMINARY AND FINAL SITE PLAN 574 6 58 582 578 582 Call before you dig. + 595.1 576 574 572 570 P.S. Know what's below. 586 580 568 58 582 572 570 562 4 56 R Proj. No. + Date 587.0 AS SHOWN + 571.00 Scale TW:570.0 BW:570.0 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com TW:575.0 BW:569.0 SP-16 SHEET 16 OF 66

Page 17

61 608 608.0 + TW:606.0 BW:606.0 610.0 + 606.7 + 607.0 + 0 61 606 608 606 SIGNATURE INVALID WITHOUT RAISED SEAL OF P.E. 610 N.J. PROFESSIONAL ENGINEER LIC. NO. 33410 PAUL W. ANDERSON 2 MATCHLINE TW:606.0 BW:603.0 606 600 606 604 602 EMER Y GENC 604 606 ACCE 60 2 SS 608 610 TW:602.0 BW:600.0 604.0 0 600.5 + 2 MATCHLINE ILD BU TW:600.0 BW:597.0 610 ING D.1 TW:598.5 BW:593.0 0 580.2 + 59 4 TW:588.0 BW:582.0 TW:586.5 BW:580.5 TW:594.5 BW:587.5 Know what's below. Call before you dig. PWA Checked by TW:590.0 BW:584.0 TW:595.0 BW:589.0 R PWA 596.8 + 58 MATCHLINE SP-16 Designed by 596 2 58 580.2 + BCA FF:618.0 GF:597.0 582 Drawn by TW:596.5 BW:590.5 Date 8 Anderson Consulting Services LLC FF:618.0 GF:606.0 59 Proj. No. 608 PRELIMINARY AND FINAL SITE PLAN 61 + AS SHOWN 60 Scale + 612.50 40 Miller Drive Boonton, NJ 07005 CERTIFICATE OF AUTHORIZATION TEl: 973.975.0703 Fax: 973.975.0703 24GA28182400 www.pwanderson-cs.com 612 MATCHLINE SP-16 SP-17 SHEET 17 OF 66

File revisions (1)