Supporting Documentation · Jul 16, 2024
96 20 Agreement WEHI Fair Share Housing Final FE 71220
da019d340905047f50b124f391ef34179db87443a9090ebf6e4decb94c8aff26Indexed text
ne Loss calculates to a number greater than zero, then the development shall satisfy the requirements of the West Orange Tree Ordinance only with respect to the Adjusted Tree Baseline Loss. Landscape Regulations 1. Street Trees. Street trees shall be provided in accordance with the West Orange Land Development Code. Additional Trees. The developer shall plant new trees and landscaping along or near the southern border of the Tract for the purpose of supplementing the buffering of the nearest residential units to the south. Any deviation from the regulations of this section shall be considered design exceptions, not variances, subject to the statutory criteria of N.J.S.A. 40:55D- 51 for relief. Signage Regulations
Development Entrance Sign. One freestanding sign shall be permitted at the entrance to the development. The sign dimensions shall have a maximum width of 10 feet and a maximum height of 8 feet. The sign may be incorporated as part of a decorative element such as a wall or fence feature, and further provided that the decorative element shall not be included in the calculation of the sign area. The top of the sign, including any decorative element framing it, shall not exceed 10 feet above grade. Identification Signage. Freestanding identification signs shall be permitted to demarcate individual buildings or sections within the development, not to exceed one such sign per building or section. The sign dimensions shall have a maximum width of 8 feet and a maximum height of 6 height, and the top of any such sign shall not exceed 8 feet above grade. This shall apply to accessory recreation or amenity uses as well, such as a clubhouse or pet service, which shall be permitted to have identification signage in accordance with the above. Building Signage. One building sign shall be permitted at each building lobby and/or building entrance. The sign dimensions for each building sign shall have a maximum width of 8 fect and a maximum height of 6 feet.
EXHIBIT C (Design Terms and Conditions)
EXHIBIT C DESIGN TERMS AND CONDITIONS WEHI shall implement the following design standards in constructing the Proposed Development: 1. General a. Reduce construction waste generation through separation of construction debris on site into separate containers for disposal or recycling. Ata minimum, the following items will be separated for recycling: i, Corrugated Cardboard ii. Clean, untreated wood iii. Scrap Metals v. Trees removed within the Limit of Disturbance (“LOD”). v. Soils if removed from site. b. Recycling: Design to accommodate recycling for tenants and to allow for the separation of solid waste from recyclable materials in accordance with the . Township’s recycling ordinance. Implement a continuous education program for recycling with new tenants, existing tenants, and guests. i. Program to include: 1. Posting of signage outlining the requirements of solid waste disposal. 2. Posting of signage outlining the requirements of the West Orange Recycling Ordinance and program. a. Signage subject to approval of the Township prior to installation. c. Cigarette Smoking Policy: Prohibition of smoking within 25 feet of all entries and prohibition of smoking within residential occupancies and all common areas. 2. Site & Landscaping: a. Implement a Tree Preservation and Replacement Plan in accordance with the following parameters: i. The tree density equals 212 trees per acre, as per the Tree Study. ii. The maximum LOD shall not exceed thirty (30) acres, as per the Zoning Amendment (“Maximum LOD”), No LOD beyond the Maximum LOD shall be permitted under any circumstances. iii. If the Maximum LOD is achieved, the maximum tree loss will be 6,360 trees (212 trees multiplied by 30 acres) (“Maximum Permitted Tree Loss”). iv. Ifless than the Maximum LOD is achieved (“Actual LOD”), then the actual tree loss (“Actual Tree Loss”) will be calculated by multiplying 212 trees by the Actual LOD (for example, if only 25.5 acres are disturbed, then the Actual Tree Loss will be 5,406 trees). y. WEHI will engage in tree planting and forest regeneration in accordance with the following activities, which are designed to provide credits against the Actual Tree Loss resulting in a net gain of trees planted and forest area
protected for regeneration so that the Actual Tree Loss is reduced to less than Zero: ie Credit for each healthy major tree (Greater than 6” diameter) within the LOD that is protected in accordance with standard tree protection procedures during development and not removed as determined by the Township Forester. Credit for each tree planted as the result of an approved landscape plan in accordance with the definition of Major (Greater than 6” Diameter Breast Height) and Minor (Less than 6” Diameter Breast Height) trees. Require that trees be native species for full credit. Prohibit invasive species as defined by the New Jersey Department of Environmental Protection, or another approved source. Provide % credit for each tree planted that is a non-native species and is non-invasive. WEHI shall install thirty (30) acres of gated access deer fencing that is eight (8) feet in height in areas of the Subject Property outside of the LOD. Fenced area will be prioritized for location between the LOD and the West Essex Highlands Condominium Association (the “Association”) to maximize regrowth and to maximize native understory growth to intercept runoff. WEHI shall receive a credit against the Actual Tree Loss in an amount of 212 trees for each acre of deer fencing installed. If WEHI fulfills its obligation and installs the thirty (30) acres of deer fencing contemplated herein, then WEHI shall receive a credit against the Actual Tree Loss in the amount of 6,360 trees. a. Deer fencing will be maintained in perpetuity. It is the parties’ intent that the installation of thirty (30) acres of deer fencing alone will reduce the Actual Tree Loss to zero or less than zero. However, should the above items, including the deer fencing, fail to reduce the Actual Tree Loss to zero or less than zero, tree planting can be offered for other locations within the Township with priority to locations within the Association where trees are needed as designated by the Township Forester. . If WEHI complies with the procedure set forth in this Site & Landscaping section, then WEHI shall have no further obligation regarding the removal or replacement of trees in connection with the construction of the Proposed Development, including but not limited to any replacement of trees or payment of fees which may otherwise be required by the Township’s Tree Protection and Removal Ordinance
nstruction of the Proposed Development, including but not limited to any replacement of trees or payment of fees which may otherwise be required by the Township’s Tree Protection and Removal Ordinance (Ordinance § 25-7) (the “Tree Ordinance”). The procedure set forth herein, if followed, shall serve as a substitute for the Tree Ordinance with respect to the Subject Property. Nothing herein shall supplement: (1) the need for a landscape plan in connection with the Proposed Development to be considered and approved by the Planning Board in accordance with MLUL;
and (2) WEHI’s obligation to install landscaping and/or buffering on or near the property owned by the Association, pursuant to WEHI’s agreement with the Association and in cooperation with the Association. 3. Building & Site Utilities: a. b. c. d. Implement underground utilities where site conditions allow. Conceal and/or screen exposed utility structures such as transformers. Install individual metering or submeters as appropriate for water, gas and electric utilities. Prewire all units for hi-speed internet. 4, Building: Energy Efficiency and Green Initiatives: a. b. Implement education of tenants in the reduction of energy, water consumption, and environmental beneficial operations. Appliances: Utilize only Energy Star appliances in all apartments. i, Do not install any unvented combustion appliances (ovens and ranges excluded). HVAC Equipment shall meet the following minimum efficiency standards: i, Furnaces shall be Energy Star Rated or have an AFUE of 95% or better. ii. Air conditioning systems shall be Energy Star Rated or have a minimum SEER of 15 and a 12.5 EER for split systems. 1. Package systems shall have a minimum SEER of 15 and an EER of 12. iii. Domestic Hot Water heaters shall be Energy Star Rated or meet the following minimum energy efficiency standard: 1. </= $5 gallon shall have an energy factor of 0.67 or better. iv. WEHI may apply to the Environmental Compliance Officer for a hardship waiver on the installation of HVAC equipment meeting the standards outlined herein. Approval of such an application shall not be unreasonably withheld. The minimum requirements for such an application shall include the following information: 1. Proof that WEHI has applied to the New Jersey Office of Clean Energy for an energy rebate package on both HVAC and Hot Water systems, A complete copy of the application shall be submitted for review. a. The full value of any rebates shall be clearly marked. 2. Evidence that the inclusion of the systems substantially interferes with the structural design of the building. 3. Financial documentation that the cost of the systems exceeds the cost of any potential rebates offered by any government agency requiring that WEHI expend a sum greater than two (2) times the cost of a system of lower energy standard.
v. The Environmental Compliance Officer shall review the application and respond within ten (10) days of receipt of all required information. vi. WEHI may appeal a negative decision to the Township Council for reconsideration. d. Utilize energy efficient double pane, low-e glazing on windows and patio doors throughout the development with the following minimum performance standards: i, Windows will have a minimum National Fenestration Rating Council (NFRC) performance standard of: 1. U Factor </=,30 2, SHGC ->/=.40 a. Window selection may be modified based on the orientation of the residential units. Windows facing East/South and West must mect both criteria. Windows facing North may waive the SHGC standard but must meet the U factor standard. ii, Patio or glass doors of any type leading from residential units to balconies or patios will have minimum National Fenestration Rating Council (NFRC) performance standard of: 1. U Factor </=.30 2, SHGC - >/=40 a. Door selection may be modified based on the orientation of the residential units. Windows facing East/South and West must meet both criteria. Windows facing North may waive the SHGC standard but must meet the U factor standard. e. Utilize Energy Star or DLC approved LED lighting throughout interior and exterior. For common area exterior site lighting, provide Dark Sky Qualified lighting and incorporate one or more of the following: i. Motion sensor controls ii. Integrative photovoltaic cells. iii, Photosensors iv. Astronomic time-clock operation Renewable energy: Design structures to allow for future incorporation of solar panels, Each lavatory faucet will have a maximum flow rate of 1.5 gallons per minute. Each toilet shall utilize no more than 1.28 gallons per flush. Each showerhead will have a maximum flow rate of 2.0 gallons per minute. Covered Parking Areas: Reduce tenant exposure to indoor pollutants from covered parking through the use of tightly sealed building envelope and natural or mechanical ventilation of enclosed parking areas per the building code standards. i. Ata minimum, all conditioned spaces above the garage shall have all penetrations and all connecting floor and ceiling joist bays sealed. ii. Electric Vehicle Charging Stations: Install electric vehicle charging stations at each building (within underground parking area) and make provisions for additional future charging
st bays sealed. ii. Electric Vehicle Charging Stations: Install electric vehicle charging stations at each building (within underground parking area) and make provisions for additional future charging stations through installation of conduit. oa Se pon
k. Bathrooms and Kitchens to be individually ventilated to minimize excess moisture and odors in each dwelling unit. L. Duct work to be protected during construction to avoid contamination. m. Install permanent walk-off mats designed to allow for cleaning at each common exterior entryway. n. In the interior of the units, use as many building components as possible based on availability, timing and cost (“cost” is defined as cost neutral for the specific product) that meet one or more of the following criteria subject to Paragraph (0) below: i. Green Seal ii. Cradle to Cradle iii. California Department of Public Health Standard Method V1,1-2010 or equivalent iv. UL Greenguard or UL Ecologo. y. Green Squared vi. SCS Global Services vii. Declare Living Future Institute viii. Forest Stewardship Council (FSC) ix. Product contains at least 25% post-consumer and 50% pre-consumer material. x. Product preference will be given to manufacturers who participate in an Extended Producer Responsibility Program. o. The use of one or more of the standards outlined in Paragraph (n) above must apply to all interior paints and coatings, adhesives, and sealants. 5. Building: Safety and Appearance a. b. f. Building will be equipped with fire sprinklers throughout. Exterior fagade materials and claddings will be selected to be low-maintenance or maintenance-free to provide a lasting quality and appearance. Install carbon monoxide detectors in each unit. Covered parking to be provided for at least 40% of required stalls. Handicap parking stalls to be distributed in both covered parking lots and open surface lots. All common areas and dwelling units to be designed to meet or exceed accessibility standards prescribed by N.J.A.C. 5:97-3.14 and the Fair Housing Act. Tenant amenities to be provided for both active and passive recreation. Among tenant amenity spaces will be interior mail room(s) and parcel package locker(s). 6. Records will be provided to verify each item outlined in this exhibit as requested by the Township of West Orange. Acceptable records will include: a. ba Receipts for products and materials.(Must be provided for all products. Pricing may be redacted). Product Labels. Product Extended Producer Responsibility Reports, Third Party standard descriptions for the specific Product,