24 010_ISSUED FOR ZONING

Preserved file SHA-256b99d7a5ad2f050c3d8b0b28fba281bf97d5801305675ad4238495e230a79eddc

Indexed text

Page 16

TED. CONTRACTOR ASSUMES RESPONSIBILITY FOR CONDITION OF SUBSTRATE WHEN HE PROCEEDS WITH GYPSUM BOARD ASSEMBLY INSTALLATION. 11. INSTALL SUPPLEMENTARY FRAMING, BLOCKING AND BRACING TO SUPPORT FIXTURES, EQUIPMENT, GRAB BARS, TOILET ACCESSORIES AND ANY ITEM FASTENED TO OR HUNG ON A WALL OR CEILING. 12. ISOLATE STEEL FRAMING FROM BUILDING STRUCTURE TO PREVENT TRANSFER OF LOADING IMPOSED BY STRUCTURAL MOVEMENT. 13. DO NOT BRIDGE BUILDING EXPANSION JOINTS AND CONTROL JOINTS WITH STEEL FRAMING OR FURRING MEMBERS. 14. INSTALLATION TOLERANCES: INSTALL EACH STEEL FRAMING MEMBER SO THAT FASTENING SURFACES DO NOT VARY MORE THAN 1/8 INCH FROM THE PLANE FORMED BY THE FACES OF ADJACENT FRAMING. 15. GYPSUM BOARD APPLICATION AND FINISHING STANDARDS: INSTALL AND FINISH GYPSUM PANELS TO COMPLY WITH ASTM C 840 AND GA-216. 16. INSTALL EDGE TRIM WHERE EDGE OF GYPSUM PANELS WOULD BE OTHERWISE EXPOSED OR SEMI-EXPOSED. PROVIDE EDGE TRIM TYPE WITH FACE FLANGE FORMED TO RECEIVE JOINT COMPOUND. 17. FOR ALL LEVELS OF GYPSUM BOARD FINISH, EMBED TAPE IN FINISHING COMPOUND PLUS TWO SEPARATE COATS APPLIED OVER JOINTS, ANGLES, FASTENER HEADS AND TRIM ACCESSORIES (NOT INCLUDING PREFILL). SAND BETWEEN COATS AND AFTER LAST COAT. 18. PROMPTLY REMOVE ALL RESIDUAL JOINT COMPOUND FROM ALL ADJACENT SURFACES. STEEL DOORS AND FRAMES 1. THIS SECTION INCLUDES THE FOLLOWING: A. DOORS: FLUSH, HOLLOW OR COMPOSITE CONSTRUCTION STANDARD STEEL DOORS FOR INTERIOR OR EXTERIOR LOCATIONS. B. FRAMES: PRESSED STEEL FRAMES FOR DOORS, TRANSOMS, SIDELIGHTS, GLAZED PANELS OTHER INTERIOR OR EXTERIOR OPENINGS. 2. SUBMIT PRODUCT DATA FOR EACH TYPE OF DOOR AND FRAME,INCLUDING DETAILS OF CORE AND EDGE CONSTRUCTION, TRIMFOR OPENING, FIRE RATING WHERE REQUIRED AND SOUND RATINGS, WHERE REQUIRED. 3. SUBMIT SHOP DRAWINGS INDICATING LOCATION AND SIZE OF EACH DOOR, ELEVATION OF EACH KIND OF DOOR, DETAILS OF CONSTRUCTION, LOCATION AND EXTENT OF HARDWARE BLOCKING, FIRE RATINGS, REQUIREMENTS OF VENEER MATCHING, FACTORY FINISHING AND ALL OTHER PERTINENT DATA. 4. QUALITY STANDARD TO BE STEEL DOOR INSTITUTE "RECOMMENDED SPECIFICATIONS STANDARD STEEL DOOR AND FRAMES" ANSI/SDI-100 AND AS SPECIFIED HEREIN. 5. COMPLY WITH NFPA 80 FOR FIRE RATED DOOR ASSEMBLIES AND BE LISTED BY UL, FACTORY MUTUAL OR WARNOCK HERSEY. 6. AT STAIR ENCLOSURES, PROVIDE DOORS WHICH HAVE TEMPERATURE RISE RATING OF 450 DEG. MAX. IN 30 MINUTES OF FIRE EXPOSURE. 7.

Page 16

ATED DOOR ASSEMBLIES AND BE LISTED BY UL, FACTORY MUTUAL OR WARNOCK HERSEY. 6. AT STAIR ENCLOSURES, PROVIDE DOORS WHICH HAVE TEMPERATURE RISE RATING OF 450 DEG. MAX. IN 30 MINUTES OF FIRE EXPOSURE. 7. DELIVER DOORS AND FRAMES CARDBOARD WRAPPED OR CRATED TO PROVIDE PROTECTION DURING TRANSIT AND JOB STORAGE. 8. INSPECT DOORS AND FRAMES UPON DELIVERY FOR DAMAGE. REMOVE AND REPLACE DAMAGED ITEMS. 9. STORE DOORS UNDER COVER AT SITE. DO NOT PERMIT DOORS AND FRAMES TO BECOME WET. 10. HOT ROLLED STEEL SHEETS: COMMERCIAL QUALITY CARBON STEEL, COMPLYING WITH ASTM A 569 AND ASTM A 568. 11. COLD ROLLED STEEL SHEETS: COMMERCIAL QUALITY CARBON STEEL, COMPLYING WITH ASTM A 366 AND ASTM A 568. 12. GALVANIZED STEEL SHEETS: ZINC COATED CARBON STEEL SHEETS OF COMMERCIAL QUALITY, COMPLYING WITH ASTM A 526, OR DRAW QUALITY, ASTM A 642, HOT DIPPED GALVANIZED PER ASTM A 525 WITH A60 OR G60 COATING DESIGNATION, MILL PHOSPHATIZED. 13. PRIME WITH RUST INHIBITIVE PAINT, SUITABLE FOR SPECIFIED PAINT, COMPLYING WITH ANSI A224.1, "TEST PROCEDURES AND ACCEPTANCE CRITERIA FOR PRIME PAINTED STEEL SURFACES FOR STEEL DOORS AND FRAMES" 14. INTERIOR DOORS SHALL MEET ANSI/SDI-100 GRADE I, STANDARD DUTY, 1-3/4 INCH THICK, MODEL 3, SEAMLESS. 15. EXTERIOR DOORS SHALL MEET THE SAME STANDARD AS INTERIOR DOORS BUT BE GALVANIZED. 16. FRAMES SHALL BE MINIMUM 18 GAGE COLD ROLLED STEEL, FABRICATED WITH MITERED CORNERS FOR KNOCKED DOWN FIELD ASSEMBLY AND BE DRILLED FOR 3 SILENCERS ON STRIKE JAMBS. PROVIDE 26 GAGE PLASTER GUARD AT BACK OF HARDWARE CUTOUTS. 17. CLEARANCES: NOT MORE THAN 1/8 INCH AT JAMBS AND HEADS AND NOT MORE THAN 3/4 INCH AT BOTTOM. 18. SET FRAMES ACCURATELY IN POSITION, PLUMBED, ALIGNED AND BRACED SECURELY. 19. INSTALL AT LEAST 3 WALL ANCHORS PER JAMB. 20. FIT HOLLOW METAL DOORS ASSEMBLY IN FRAMES WITH CLEARANCES SPECIFIED IN ANSI/SDI-100. 21. FINAL ADJUSTMENT: CHECK AND READJUST OPERATING HARDWARE ITEMS, LEAVING STEEL DOORS AND FRAMES UNDAMAGED AND IM COMPLETE AND PROPER OPERATING CONDITION. GENERAL NOTES 1. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION AND SCHEDULING OF ALL SUBCONTRACTORS, INCLUDING ALL WORKERS OF OWNER'S AND TENANT'S VENDORS. 2. GENERAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL CONSTRUCTION PERMITS. 3. GENERAL CONTRACTOR AND ALL OF HIS SUBCONTRACTORS SHALL VISIT THE SITE AND EVALUATE THE EXISTING CONDITIONS. ANY DISCREPANCIES BETWEEN THE EXISTING SITE CONDITIONS

Page 16

PAY FOR ALL CONSTRUCTION PERMITS. 3. GENERAL CONTRACTOR AND ALL OF HIS SUBCONTRACTORS SHALL VISIT THE SITE AND EVALUATE THE EXISTING CONDITIONS. ANY DISCREPANCIES BETWEEN THE EXISTING SITE CONDITIONS AND THE ARCHITECTURAL DRAWINGS AND SPECS SHALL BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. FAILURE TO DO SO SHALL CONSTITUTE ACCEPTANCE BY THE BIDDER OF ALL EXISTING CONDITIONS AND NO CHANGE ORDERS WILL BE ISSUED TO REMEDY PROBLEMS ARISING FROM SUCH DISCREPANCIES. 4. GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS AND SHOP DRAWINGS ON SITE DURING ALL PHASES OF THE PROJECT FOR USE BY ALL TRADES AND WILL MARK-UP ALL CHANGES ON THE DRAWINGS TO BE "AS-BUILT". 5. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL HAVE AND MAINTAIN AT ALL TIMES DURING THE PROJECT THE FOLLOWING INSURANCE COVERAGE AND SHALL SUBMIT TO THE OWNER/TENANT CERTIFICATES OF INSURANCE SHOWING COVERAGE FOR THIS PROJECT. WORKMEN'S COMPENSATION GENERAL LIABILITY AUTOMOBILE LIABILITY UMBRELLA LIABILITY 6. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL HOLD THE ARCHITECT HARMLESS AGAINST ALL CLAIMS FOR DAMAGES ARISING FROM THE WORK IN THIS PROJECT. 7. WITHIN FIVE (5) WORKING DAYS OF THE EXECUTION OF THE CONTRACT, THE CONTRACTOR SHALL SUBMIT TO THE OWNER/TENANT A SCHEDULE OF CONSTRUCTION SHOWING DATES OF EACH PHASE AND TYPE OF WORK TO BE PERFORMED. UPON OWNER/TENANT REVIEW AND APPROVAL, THIS SCHEDULE SHALL DETERMINE COMPLIANCE WITH CONTRACTUAL DATES COMPLETION. 8. SHOP DRAWINGS, MANUFACTURER'S BROCHURES, TECHNICAL INFORMATION AND SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW IN A TIMELY MANNER TO ALLOW TEN (10) WORKING DAYS FOR SAID REVIEW. LATE SUBMISSION OF REQUIRED INFORMATION AND SHOP DRAWINGS BY THE CONTRACTOR DOES NOT RELIEVE THE CONTRACTOR OF HIS OBLIGATIONS TO FINISH CONSTRUCTION ON TIME AND WILL NOT OBLIGATE THE OWNER/TENANT TO ISSUE A TIME EXTENSION TO THE CONTRACT. 9. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTROLLING ACCESS TO THE WORK AREA. ALL PRECAUTIONS SHALL BE TAKEN TO PROTECT THE OCCUPANTS OF ADJACENT AREAS FROM GAINING ENTRY TO THE WORK AREA. ALL DUST, DEBRIS AND NOISE SHALL BE CONFINED TO THE WORK AREA. 10. EXISTING FURNISHINGS SHALL BE REMOVED BY OTHERS PRIOR TO START OF CONSTRUCTION. IF ANY FURNISHINGS ARE IN PLACE AT THE START OF CONSTRUCTION, CONTRACTOR SHALL INQUIRE ABOUT THE STATUS OF SUCH FURNISHINGS WITH THE

Page 16

NISHINGS SHALL BE REMOVED BY OTHERS PRIOR TO START OF CONSTRUCTION. IF ANY FURNISHINGS ARE IN PLACE AT THE START OF CONSTRUCTION, CONTRACTOR SHALL INQUIRE ABOUT THE STATUS OF SUCH FURNISHINGS WITH THE OWNER/TENANT. 11. ANY ITEM SHOWN ON THE CONTRACT DOCUMENTS TO BE REUSED SHALL BE CAREFULLY REMOVED AND STORED UNTIL NEEDED. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGED TO SUCH ITEMS. 12. CONTRACTOR SHALL NOT SCALE DIMENSIONS OFF THE DRAWINGS. 13. ANY IRREGULARITIES OBSERVED DURING THE LAYOUT OF NEW WALLS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S/TENANTS' PROJECT MANAGER FOR RESOLUTION. CONTRACTOR SHALL NOT DECIDE WHAT ADJUSTMENTS CAN BE MADE TO ACCOMMODATE FIELD CONDITIONS. LAYOUT REVISIONS SHALL BE AT NO ADDITIONAL COST TO THE OWNER. 14. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL CONFORM WITH ALL LOCAL, STATE AND FEDERAL RULES AND REGULATIONS HAVING JURISDICTION OVER THIS CONTRACT. 15. CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH BUILDING MANAGER TO INSURE THE OCCUPANTS SAFETY. DELIVERIES, DEBRIS REMOVAL, USE OF BUILDING'S ELEVATORS AND ACCESS TO THE SITE REQUIRE THE REVIEW AND APPROVAL OF THE BUILDING MANAGER. 16. SUBSTITUTIONS FOR SPECIFIED ITEMS AND MATERIALS SHALL NOT BE MADE WITHOUT PRIOR REVIEW AND WRITTEN APPROVAL BY THE ARCHITECT. 17. ALL WORK SHALL BE WARRANTED AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR, UNLESS NOTED OTHERWISE, FROM THE DATE OF FINAL ACCEPTANCE. FINAL ACCEPTANCE IS MADE AFTER ALL SYSTEMS ARE BALANCED, OPERATIONAL AND ALL PUNCH LIST ITEMS HAVE BEEN CORRECTED. 18. GENERAL CONTRACTOR IS RESPONSIBLE FOR DISTRIBUTION OF DRAWINGS AND INFORMATION NEEDED BY OTHER CONTRACTORS AND SUBCONTRACTORS TO PERFORM ALL CONSTRUCTION IN A COORDINATED MANNER. 19. PRIOR TO BIDDING, ALL CONTRACTORS AND SUBCONTRACTORS SHALL INQUIRE ABOUT ALL MATTERS THAT MIGHT EFFECT THEIR ABILITY TO PERFORM WORK IN THIS CONTRACT AND MAKE ALL NECESSARY ALLOWANCES IN THEIR BID. UPON AWARD, NO CHANGE ORDERS SHALL BE ISSUED TO CORRECT A PROBLEM ENCOUNTERED BY THE CONTRACTOR THAT WAS EVIDENT PRIOR TO BIDDING. 20. ALL BIDDERS SHALL INQUIRE ABOUT ANY WORK THAT IS REQUIRED TO BE PERFORMED DURING OTHER THAN NORMAL WORKING HOURS PRIOR TO BIDDING AND INCLUDE ALL EXTRA COSTS IN THEIR BID. 21. THESE CONSTRUCTION DRAWINGS AND DOCUMENTS DO NOT ASSIGN WORK TO A SPECIFIC TRADE OR SUBCONTRACTOR. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO

Page 16

G AND INCLUDE ALL EXTRA COSTS IN THEIR BID. 21. THESE CONSTRUCTION DRAWINGS AND DOCUMENTS DO NOT ASSIGN WORK TO A SPECIFIC TRADE OR SUBCONTRACTOR. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DIVIDE THE WORK AMONG HIS SUPPLIERS AND SUBCONTRACTORS AS HE SEES FIT AND ACCORDING TO HIS CONTRACTUAL AGREEMENT WITH HIS SUPPLIERS AND SUBCONTRACTORS. 22. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WORK INDICATED IN THE CONSTRUCTION DRAWINGS AND DOCUMENTS. ANY ITEMS NOT SPECIFICALLY MENTIONED BUT REQUIRED TO MAKE THE WORK COMPLETE SHALL BE INCLUDED AT NO ADDITIONAL COST TO THE OWNER. ASBESTOS ABATEMENT 1. THERE IS NO ASBESTOS RELATED WORK IN THIS CONTRACT. 2. THE BUILDING IN WHICH THIS CONTRACT IS TO BE PERFORMED MAY HAVE ASBESTOS CONTAINING MATERIAL. THE OWNER SHALL INFORM THE BIDDERS, IF IT IS KNOWN TO CONTAIN ACM AND SHALL ARRANGE FOR A LICENSED ASBESTOS ABATEMENT CONTRACTOR TO ABATE OR REMOVE THE ASBESTOS CONTAINING MATERIAL SEPARATE FROM THIS CONTRACT. 3. IF THE CONTRACTOR UNCOVERS OR DISCOVERS A MATERIAL THAT MAY CONTAIN ASBESTOS, WORK SHALL STOP IMMEDIATELY AND THE OWNER'S PROJECT MANAGER SHALL BE NOTIFIED. THE OWNER SHALL ARRANGE FOR A TESTING LAB TO CONFIRM THE EXISTENCE OF ASBESTOS AND ARRANGE FOR ITS ABATEMENT OR REMOVAL. MOLD AND MILDEW 1. THERE IS NO MOLD OR MILDEW RELATED WORK IN THIS CONTRACT. IF THE PRESENCE OF MOLD OR MILDEW IS SUSPECTED, CONFIRMATION AND REMEDIATION SHALL BE UNDERTAKEN BY OTHERS TRAINED, LICENSED AND INSURED FOR THAT TYPE OF WORK. RADON MITIGATION 1. ALL CONSTRUCTION SHALL COMPLY WITH N.J.A.C. 5:23-10 RADON HAZARD SUBCODE, OF THE UNIFORM CONSTRUCTION CODE. PAINTING 1. THIS SECTION INCLUDES SURFACE PREPARATION, PAINTING AND FINISHING OF EXPOSED INTERIOR ITEMS AND SURFACES. 2. PAINT EXPOSED SURFACES WHETHER OR NOT COLORS ARE DESIGNATED IN SCHEDULES, EXCEPT WHERE A SURFACE OR MATERIAL IS SPECIFICALLY INDICATED NOT TO BE PAINTED OR IS TO REMAIN NATURAL. WHERE AN ITEM OR SURFACE IS NOT SPECIFICALLY MENTIONED, PAINT THE SAME AS SIMILAR ADJACENT MATERIALS OR SURFACES. IF COLOR OR FINISH IS NOT DESIGNATED, THE ARCHITECT WILL SELECT FROM STANDARD COLORS OR FINISHES AVAILABLE. 3. PAINTING IS NOT REQUIRED ON PREFINISHED ITEMS, FINISHED METAL SURFACES, CONCEALED SURFACES, OPERATING PARTS AND LABELS. 4. DO NOT PAINT OVER UNDERWRITERS LABORATORIES, FACTORY MUTUAL OR OTHER CODE REQUIRED LABELS OR EQUIPMENT NAME,

Page 16

FINISHED ITEMS, FINISHED METAL SURFACES, CONCEALED SURFACES, OPERATING PARTS AND LABELS. 4. DO NOT PAINT OVER UNDERWRITERS LABORATORIES, FACTORY MUTUAL OR OTHER CODE REQUIRED LABELS OR EQUIPMENT NAME, IDENTIFICATION PERFORMANCE RATING OR NOMENCLATURE PLATES. 5. SUBMIT PRODUCT DATA FOR EACH PAINT SYSTEM SPECIFIED, INCLUDING BLOCK FILLERS AND PRIMERS. CERTIFY THAT PRODUCTS COMPLY WITH LOCAL REGULATIONS CONTROLLING USE OF VOLATILE ORGANIC COMPOUNDS (VOCs). 6. PAINTING CONTRACTOR SHALL BE AN EXPERIENCED APPLICATOR WHO HAS COMPLETED PAINTING SYSTEM APPLICATIONS SIMILAR IN MATERIAL AND EXTENT TO THOSE INDICATED FOR THE PROJECT THAT HAVE RESULTED IN A CONSTRUCTION RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE. 7. ALL PRIMERS, UNDERCOAT AND FINISH COAT PAINTS SHALL BE PRODUCED BY THE SAME MANUFACTURER. 8. DELIVER MATERIALS TO THE JOB SITE IN THE MANUFACTURER'S ORIGINAL UNOPENED PACKAGES AND CONTAINERS BEARING MFR'S. NAME AND LABEL, AND THE FOLLOWING INFORMATION: A. PRODUCT NAME OR TITLE OF MATERIAL. B. PRODUCT DESCRIPTION. C. MFR'S. STOCK NUMBER AND DATE OF MANUFACTURE. D. CONTENTS BY VOLUME, FOR PIGMENT AND VEHICLE CONSTITUENTS. E. THINNING INSTRUCTIONS. F. APPLICATION INSTRUCTIONS. G. COLOR NAME AND NUMBER. 9. STORE MATERIALS NOT IN USE IN TIGHTLY COVERED CONTAINERS IN A WELL VENTILATED AREA AT A MINIMUM AMBIENT TEMPERATURE OF 45 DEG. PROTECT FROM FREEZING. REMOVE OILY RAGS AND WASTE DAILY. TAKE NECESSARY MEASURES TO ENSURE THAT WORKERS AND WORK AREAS ARE PROTECTED FROM FIRE AND HEALTH HAZARDS RESULTING FROM HANDLING, MIXING AND APPLICATION. 10. APPLY WATER BASED PAINTS ONLY WHEN THE TEMPERATURE OF SURFACES TO BE PAINTED AND SURROUNDING AIR TEMPERATURES ARE BETWEEN 50 DEG. AND 90 DEG. 11. APPLY SOLVENT THINNED PAINTS ONLY WHEN THE TEMPERATURES OF SURFACES TO BE PAINTED AND SURROUNDING AIR TEMPERATURES ARE BETWEEN 45 DEG. AND 95 DEG. 12. EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH PAINTING WILL BE PERFORMED FOR COMPLIANCE WITH PAINT APPLICATION REQUIREMENTS. SURFACES RECEIVING PAINT MUST BE THOROUGHLY DRY BEFORE PAINT IS APPLIED. DO NOT BEGIN TO APPLY PAINT UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 13. START OF PAINTING WILL BE CONSTRUED AS THE APPLICATOR'S ACCEPTANCE OF SURFACES AND CONDITIONS WITHIN A PARTICULAR AREA. 14. CLEAN AND PREPARE SURFACES TO BE PAINTED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS FOR EACH PARTICULAR SUBSTRATE CONDITION AND AS

Page 16

ACCEPTANCE OF SURFACES AND CONDITIONS WITHIN A PARTICULAR AREA. 14. CLEAN AND PREPARE SURFACES TO BE PAINTED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS FOR EACH PARTICULAR SUBSTRATE CONDITION AND AS SPECIFIED. 15. APPLY MATERIALS NO THINNER THAN THE MANUFACTURER'S RECOMMENDED SPREADING RATE. PROVIDE THE TOTAL DRY FILM THICKNESS OF THE ENTIRE SYSTEM AS RECOMMENDED BY THE MANUFACTURER. 16. MATCH APPROVED SAMPLES FOR COLOR, TEXTURE AND COVERAGE. REMOVE, REFINISH OR REPAINT WORK NOT COMPLYING WITH SPECIFIED REQUIREMENTS. 17. CLEANUP: AT THE END OF EACH WORK DAY, REMOVE EMPTY CANS, RAGS RUBBISH AND OTHER DISCARDED PAINT MATERIALS FROM THE SITE. 18. CLEAN PAINT SPATTERED SURFACES. REMOVE PAINT SPATTERED PAINT BY WASHING AND SCRAPING. BE CAREFUL NOT TO SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES. 19. PROTECT WORK OF OTHER TRADES. CORRECT DAMAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS ACCEPTABLE BY THE ARCHITECT. 20. PROVIDE "WET PAINT" SIGNS TO PROTECT NEWLY PAINTED FINISHES. 21. AT COMPLETION OF CONSTRUCTION ACTIVITIES OF OTHER TRADES, TOUCH UP AND RESTORE DAMAGED OR DEFACED PAINTED SURFACES. ABBREVIATIONS RIGID INSULATION BATT INSULATION EARTH BRICK CONCRETE METALGYPSUM BOARD CONCRETE MASONRY UNITWOOD ROUGH FRAMING SHIM PLYWOOD WOOD POROUS FILL PRECAST STONE MATERIAL LEGEND GENERAL NOTES DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-501 OF 24-010 1716 SHEET:

Page 17

REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 CONCRETE 1. ALL CONCRETE WORK IS DESIGNED ON THE BASIS OF "STRENGTH DESIGN" IN ACCORDANCE WITH ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". ALL CONCRETE WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 318. 2. CONCRETE WORK SHALL BE PROPORTIONED IN ACCORDANCE WITH ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE" AND ACI 211.1,"RECOMMENDED PRACTICES FOR SELECTING PROPORTIONS FOR NORMAL WEIGHT CONCRETE", TO PRODUCE A 28 DAY COMPRESSIVE STRENGTH OF 3500 PSI, UNLESS NOTED OTHERWISE. 3. NO WATER SHALL BE ADDED TO THE CONCRETE MIX AT THE JOB SITE WITHOUT THE APPROVAL OF THE ENGINEER. 4. ALL AGGREGATE SHALL CONFORM TO ASTM C-33. 5. ADMIXTURES MAY BE USED ONLY AFTER THE REVIEW AND APPROVAL BY THE ARCHITECT. 6. CONCRETE COVER FOR REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI 318, AND SHALL BE, MINIMALLY, AS LISTED BELOW: SLABS - 3/4" UNFORMED CONCRETE BELOW GRADE - 3" FORMED CONCRETE BELOW GRADE - 2" 7. ALL REINFORCING STEEL SHALL COMPLY WITH ASTM A 615 AND/OR ASTM A 617. 8. ALL REINFORCING STEEL SHALL: A. COMPLY WITH ASTM A 615 AND OR ASTM A 617 B. BE GRADE 60 C. BE SPLICED IN ACCORDANCE WITH ACI 318 BE ACCURATELY PLACED, RIGIDLY SUPPORTED AND FIRMLY TIED IN PLACE WITH BAR SUPPORTS AND SPACERS, IN ACCORDANCE WITH ACI 318 AND ACI 301. 9. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 AND BE POSITIONED SO AS TO BE IN THE CENTER OF DEPTH OF THE SLAB. 10. CONCRETE SLABS SHALL BE, UNLESS OTHERWISE NOTED, 4" THICK WITH 6X6-W1.4XW1.4 (6X6-10X10) WELDED WIRE FABRIC ON 6 MIL THICK POLYETHYLENE SHEET ON 4" COMPACTED GRAVEL OR CRUSHED STONE. 11. JOINTS SHALL OCCUR A MAXIMUM OF 3 TIMES IN FEET THE DEPTH OF THE CONCRETE SLAB IN INCHES. FOR EXAMPLE, 4" SLAB SHALL HAVE JOINTS 12' ON CENTER MAXIMUM. CARPET 1. THIS SECTION INCLUDES THE FOLLOWING: A. CARPETING B. INSTALLATION C. ACCESSORIES D. CUSHION (REFER TO FINISH PLAN FOR SCHEDULE OF WHICH ITEMS ABOVE ARE BEING USED IN THIS PROJECT) 2. SUBMIT PRODUCT DATA FOR EACH TYPE OF CARPET MATERIAL AND INSTALLATION ACCESSORY REQUIRED. SUBMIT WRITTEN DATA ON PHYSICAL CHARACTERISTICS, DURABILITY, RESISTANCE TO FADING AND FLAME RESISTANCE CHARACTERISTICS. 3. SUBMIT SHOP DRAWINGS SHOWING LAYOUT AND SEAMING DIAGRAMS. INDICATE PILE OR PATTERN DIRECTIONS AND LOCATION AND TYPE OF EDGE STRIPS. INDICATE COLUMNS, DOORWAYS, ENCLOSING WALLS OR PARTITIONS, BUILT-IN

Page 17

SUBMIT SHOP DRAWINGS SHOWING LAYOUT AND SEAMING DIAGRAMS. INDICATE PILE OR PATTERN DIRECTIONS AND LOCATION AND TYPE OF EDGE STRIPS. INDICATE COLUMNS, DOORWAYS, ENCLOSING WALLS OR PARTITIONS, BUILT-IN CABINETS AND LOCATIONS WHERE CUTOUTS ARE REQUIRED IN CARPET. SHOW INSTALLATION DETAILS AT SPECIAL CONDITIONS. 4. SUBMIT SAMPLES SHOWING FULL RANGE OF COLOR, TEXTURE, AND PATTERN VARIATIONS EXPECTED. PREPARE SAMPLES FROM SAME MATERIAL TO BE USED FOR THE WORK. SUBMIT, AS A MINIMUM: A. 12 INCH SQUARE SAMPLE OF EACH TYPE OF CARPET MATERIAL REQUIRED. B. 12 INCH LONG SAMPLE OF EACH TYPE OF EDGE STRIPPING AND ACCESSORY ITEM. C. 6 INCH SQUARE OF EACH TYPE OF CARPET CUSHION. 5. ALL CARPETING SHALL PASS DOC-FF-1-70 TEST. 6. ALL CARPET CUSHION SHALL PASS DOC-FF-1-70 TEST AND HAVE A FLAME SPREAD OF 25 OR LESS BY ASTM E 84. 7. DELIVER MATERIALS TO PROJECT SITE IN ORIGINAL FACTORY WRAPPINGS AND CONTAINERS, LABELED WITH IDENTIFICATION OF MANUFACTURER, BRAND NAME, AND LOT NUMBER. 8. STORE MATERIALS INSIDE WELL VENTILATED AREA PROTECTED FROM WEATHER, MOISTURE, SOILAGE, EXTREME TEMPERATURES AND HUMIDITY. PROJECT SHALL MEET THE FOLLOWING CONDITIONS: A. NO CONDENSATION WITH 48 HOURS ON UNDERSIDE OF 4 FOOT BY 4 FOOT POLYETHYLENE SHEET, FULLY TAPED AT PERIMETER TO SUBSTRATE. B. pH OF 9 OR LESS WHEN SUBSTRATE WETTED WITH POTABLE WATER AND pHYDRION PAPER APPLIED. 9. FURNISH EXTRA MATERIALS MATCHING PRODUCTS INSTALLED AS CALLED FOR IN THE CONTRACT DRAWINGS, PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS, IN THE FOLLOWING AMOUNTS: A. CARPET: BEFORE INSTALLATION BEGINS, FURNISH QUANTITY OF FULL WIDTH FOR EACH TYPE OF MATERIAL EQUAL TO 5 PERCENT OF AMOUNT INSTALLED. 10. CLEAR AWAY DEBRIS AND SCRAPE UP CEMENTITIOUS DEPOSITS FROM CONCRETE SURFACES TO RECEIVE CARPET. APPLY SEALER TO PREVENT DUSTING. 11. PATCH HOLES AND LEVEL TO A SMOOTH SURFACE. IF PREVIOUS FINISH IS CHEMICALLY STRIPPED, RESEAL CONCRETE. SEAL POWDERY OR POROUS SURFACES WITH SEALER RECOMMENDED BY CARPET MFR. 12. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR SEAM LOCATIONS AND DIRECTION OF CARPET. MAINTAIN UNIFORMITY OF CARPET DIRECTION AND LAY OF PILE. AT DOORWAYS, CENTER SEAMS UNDER DOOR IN CLOSED POSITION. DO NOT PLACE SEAMS SO AS TO BE PERPENDICULAR TO DOOR FRAMES. DO NO BRIDGE BUILDING EXPANSION JOINTS WITH CONTINUOUS CARPET. 13. EXTEND CARPET UNDER REMOVABLE FLANGES AND

Page 17

UNDER DOOR IN CLOSED POSITION. DO NOT PLACE SEAMS SO AS TO BE PERPENDICULAR TO DOOR FRAMES. DO NO BRIDGE BUILDING EXPANSION JOINTS WITH CONTINUOUS CARPET. 13. EXTEND CARPET UNDER REMOVABLE FLANGES AND FURNISHINGS AND INTO ALCOVES AND CLOSETS OF EACH SPACE. 14. PROVIDE CUTOUTS WHERE REQUIRED, AND BIND CUT EDGES WHERE NOT CONCEALED BY PROTECTIVE EDGE GUARDS OR OVERLAPPING FLANGES. 15. INSTALL CARPET EDGE GUARD WHERE EDGE OF CARPET IS EXPOSED. ANCHOR GUARDS TO SUBSTRATE. 16. INSTALL TACKLESS CARPET STRIPPING BY NAILING. LOCATE TO ENSURE CONCEALMENT OF CARPET EDGE BETWEEN STRIPPING AND BASE OF WALL. LAY STRIP AT ENTIRE PERIMETER OF CARPETED SPACE, CUTOUTS AND OBSTRUCTIONS. PROVIDE NARROW STRIPPING WITH 2 ROWS OF PINS WHERE STRETCHED WIDTH OF CARPET IS 20 FEET OR LESS. STRIPPING WITH 3 ROWS OF PINS WHERE CARPET WIDTH EXCEEDS 20 FEET. 17. INSTALL CUSHION SEAMS AT 90 DEGREE ANGLE WITH CARPET SEAMS. PLACE CUSHION FACE UP AS RECOMMENDED BY CUSHION MFR. APPLY MINIMUM 2 INCH FABRIC TYPE ADHESIVE TAPE ON CUSHION SEAMS. IN RAMPED FLOOR AREAS, INCREASE ANCHORAGE OR ADHESIVE. BOND CARPET CUSHION TO SUBSTRATE. 18. INSTALL WITH PATTERN PARALLEL TO WALLS AND BORDERS. 19. STRETCH CARPET TO PROVIDE SMOOTH, RIPPLE FREE, TAUT EDGES. USE POWER STRETCHER WHERE CARPET LENGTH IS GREATER THAN 20 FEET. 20. FIT SECTIONS OF CARPET PRIOR TO APPLICATION OF ADHESIVE. TRIM EDGES AND BUTT CUTS WITH SEAMING CEMENT. 21. APPLY ADHESIVE UNIFORMLY TO SUBSTRATE IN ACCORDANCE WITH MFR.'S INSTRUCTIONS BUTT EDGES TIGHT TO FORM SEAMS WITHOUT GAPS. ROLL ENTIRE AREA LIGHTLY TO ELIMINATE AIR POCKETS AND ENSURE UNIFORM BOND. 22. REMOVE ADHESIVE FROM CARPET SURFACE WITH MANUFACTURER'S RECOMMENDED CLEANING AGENT. 23. REMOVE AND DISPOSE OF DEBRIS AND UNUSABLE SCRAPS. VACUUM WITH COMMERCIAL MACHINE WITH FACE-BEATER ELEMENT. REMOVE SOIL. REPLACE CARPET WHERE SOIL CANNOT BE REMOVED. REMOVE PROTRUDING FACE YARN. VACUUM CARPET. 24. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS, IN A MANNER ACCEPTABLE TO MANUFACTURER AND INSTALLER, TO ENSURE CARPET IS NOT DAMAGED OR DETERIORATED AT TIME OF SUBSTANTIAL COMPLETION. RESILIENT TILE FLOORING 1. THIS SECTION INCLUDES THE FOLLOWING: A. HOMOGENOUS (SOLID) VINYL FLOOR TILE. B. RUBBER FLOOR TILE. C. VINYL COMPOSITION FLOOR TILE. D. RESILIENT VINYL WALL BASE. (REFER TO FINISH PLAN FOR SCHEDULE OF WHICH ITEMS ABOVE ARE BEING USED IN THIS PROJECT) 2. SUBMIT PRODUCT DATA FOR