Page 9

SOUTH BRANCH RAHWAY RIVER BLOCK 157 LOT 5 N/F LANDS OF DIENER MT. PLEASANT ASSOCIATES LTD D.B. 12518, PG. 3496 BLOCK 157 LOT 8.03 BLOCK 157 LOT 8.02 BLOCK 157 LOT 8.06 BLOCK 157 LOT 8.01 BLOCK 157 LOT 2 BLOCK 157 LOT 11 BLOCK 157 LOT 1 P.O.B. D.B. 12518, PG. 3496 S12°02'43"W S57°31'17"E 92.97' 170.11' 80.15' 170.23'S85°32'47"E BROOK PLACE MOUNT PLEASANT PLACE MOUNT PLEASANT AVENUE PLEASANT VALLEY WAY S52°30'47"E 52.89'(D) 52.77' S78°46'47"E 39.72'(D) 39.66' N46°40'43"E 18.84' S57°30'47"E 101.63' 145.92'S17°02'23"W 328.07'N74°42'17"W 103.59'N78°59'17"W N88°23'17"W N27°00'33"E 180.57' S84°16'57"W 109.05' N29°03'57"E 50.23' N84°16'57"E 107.12' N27°00'33"E 100.44' N28°06'13"E 46.04' W E S SOUTH BRANCH RAHWAY RIVER SOUTH BRANCH RAHWAY RIVER FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA EXISTING BUILDING TO REMAIN PROP RETAIL SPACE (± 17,245 SF FIRST FLOOR) (± 1,522 SF MEZZANINE) 187 PARKING STALLS 30' FRONT YARD SETBACK 30' FRONT YARD SETBACK 10' SIDE YARD SETBACK 10' SIDE YARD SETBACK 10' SIDE YARD SETBACK10' SIDE YARD SETBACK 10' SIDE YARD SETBACK 10' SIDE YARD SETBACK 10' PARKING SETBACK 10' SIDE YARD SETBACK10' PARKING SETBACK 10' PARKING SETBACK 10' SIDE YARD SETBACK 30' FRONT YARD SETBACK 30' REAR YARD SETBACK APPROX LOCATION OF PROP SAWCUT LINE AND PAVEMENT REPAIR STRIP, AS REQUIRED FHA ELEVATION = 369.9 FT BASED ON METHOD 3 DELINEATION APPROX LOCATION OF PROP SAWCUT LINE AND PAVEMENT REPAIR STRIP, AS REQUIRED EXIST WATER SERVICE CONNECTION TO REMAIN (REFER TO MEP PLANS) (CONTRACTOR TO VERIFY LOCATION AND CONDITION OF EXISTING WATER SERVICE SYSTEM IN THE FIELD. CONTRACTOR TO VERIFY FEASIBILITY OF CONNECTION WITH NJAW) EXIST ELECTRIC SERVICE CONNECTION TO REMAIN (REFER TO MEP PLANS) (CONTRACTOR TO VERIFY LOCATION AND CONDITION OF EXISTING ELECTRIC SERVICE SYSTEM IN THE FIELD. CONTRACTOR TO VERIFY FEASIBILITY OF CONNECTION WITH PSE&G) APPROX LOCATION OF EXISTING SANITARY SEWER LINE AND CONNECTION TO REMAIN. CONTRACTOR TO CONFIRM INVERT AND LOCATION OF EXISTING SANITARY SEWER IN THE FIELD PRIOR TO CONSTRUCTION. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION. APPROX LOCATION OF EXISTING SANITARY SEWER LINE AND CONNECTION TO REMAIN. CONTRACTOR TO CONFIRM INVERT AND LOCATION OF EXISTING SANITARY SEWER IN THE FIELD PRIOR TO

Page 9

LITY COMPANY PRIOR TO CONSTRUCTION. APPROX LOCATION OF EXISTING SANITARY SEWER LINE AND CONNECTION TO REMAIN. CONTRACTOR TO CONFIRM INVERT AND LOCATION OF EXISTING SANITARY SEWER IN THE FIELD PRIOR TO CONSTRUCTION. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION. EXIST GAS SERVICE CONNECTION TO REMAIN (REFER TO MEP PLANS) (CONTRACTOR TO VERIFY LOCATION AND CONDITION OF EXISTING GAS SERVICE SYSTEM IN THE FIELD. CONTRACTOR TO VERIFY FEASIBILITY OF CONNECTION WITH PSE&G) CONTRACTOR TO CONFIRM LOCATION OF EXIST MONITORING WELLS AND COORDINATE RELOCATION WITH LSRP AS REQUIRED. PROP SANITARY - STORM PIPE CROSSING. CONTRACTOR TO CONFIRM LOCATION, INVERTS, CLEARANCE, AND SLOPE OF EXIST SAN SEWER IN THE FIELD AND FEASIBILITY OF CROSSING WITH PROP STORM PIPE. CONTRACTOR TO NOTIFY ENGINEER OF RECORD PRIOR TO CONSTRUCTION IF CONFLICT ARISES. CONTRACTOR TO VERIFY UNKNOWN EXIST UTILITY TYPE, SIZE, LOCATION, AND CONDITION IN THE FIELD EXIST FIRE HYDRANT EXIST FIRE HYDRANT CONTRACTOR TO CONFIRM LOCATION OF EXIST MONITORING WELLS AND COORDINATE RELOCATION WITH LSRP AS REQUIRED. CONTRACTOR TO CONFIRM LOCATION OF EXIST MONITORING WELLS AND COORDINATE RELOCATION WITH LSRP AS REQUIRED. CONTRACTOR TO CONFIRM LOCATION OF EXIST MONITORING WELLS AND COORDINATE RELOCATION WITH LSRP AS REQUIRED. CONTRACTOR TO CONFIRM LOCATION OF EXIST MONITORING WELLS AND COORDINATE RELOCATION WITH LSRP AS REQUIRED. CONTRACTOR TO VERIFY UNKNOWN EXIST UTILITY TYPE, SIZE, LOCATION, AND CONDITION IN THE FIELD CONTRACTOR TO VERIFY UNKNOWN EXIST UTILITY TYPE, SIZE, LOCATION, AND CONDITION IN THE FIELD D D D 369 374 373 372 371 370 368 375 369 369 370 FFE: 370.10 369 HATCH LEGEND PROP FULL DEPTH ASPHALT PAVEMENT PROP PERVIOUS ASPHALT PAVEMENT PROP MILL AND OVERLAY PAVEMENT PROP CONCRETE SIDEWALK PROP HEAVY-DUTY CONCRETE PAVEMENT PROP CONCRETE PAVEMENT LEGEND PROPERTY LINE TOP OF BANK 50 FT NJDEP RIPARIAN BUFFER WIDTH WETLAND BOUNDARY 50 FT WETLAND BUFFER WIDTH FHA ELEVATION (BASED ON METHOD 3 DELINEATION) FHA THIS PLAN TO BE UTILIZED FOR DRAINAGE AND UTILITIES PURPOSES ONLY. REFER TO GENERAL NOTES AND LEGEND SHEET FOR ADDITIONAL NOTES, REFERENCES AND SPECIFICATIONS. C-501 UTILITY PLAN 0 SCALE: 1" = 30' 30 307.515 PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GDUL-NJA230139.00-1A----->LAYOUT: C-501

Page 9

0 SCALE: 1" = 30' 30 307.515 PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-GDUL-NJA230139.00-1A----->LAYOUT: C-501 UTIL TH THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA230139.00-1A CRA / TGH TXL 08/14/2025 P-CIVL-GDUL PRELIMINARY & FINAL MAJOR SITE PLAN PROPOSED RETAIL STORE MAP: 87 | BLK: 157 | LOT: 5 457 MOUNT PLEASANT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY 1 REVISION 1 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 09/17/2025 REV. PER SCD COMMENTS. TGH TXL 09/17/2025 ISSUED FOR MUNICIPAL & AGENCY REVIEW & APPROVAL 30 INDEPENDENCE BLVD., SUITE 200 WARREN, NJ 07059 Phone: (908) 668-8300 Fax: (908) 754-4401 www.BohlerEngineering.com NJ CERT. OF AUTHORIZATION NO. 24GA28400600 & MH000122 BOHLER ENGINEERING NJ, LLC TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES TM BOHLER Sep 24, 2025 NEW JERSEY YOU MUST CALL 811 BEFORE ANY EXCAVATION WHETHER IT'S ON PRIVATE OR PUBLIC LAND. 1-800-272-1000 www.nj1-call.org Know what's below. Callbefore you dig. PROFESSIONAL ENGINEER T. LAM NEW JERSEY LICENSE No. 47863 NEW YORK LICENSE No. 092942 CONNECTICUT LICENSE No. 30024 PENNSYLVANIA LICENSE No. 76746 DRAINAGE AND UTILITY NOTES (Rev. 3/2023) 1. THE GENERAL NOTES MUST BE INCLUDED AS PART OF THIS ENTIRE DOCUMENT PACKAGE AND ARE PART OF THE CONTRACT DOCUMENTS. THE GENERAL NOTES ARE REFERENCED HEREIN, AND THE CONTRACTOR MUST REFER TO THEM AND FULLY COMPLY WITH THESE NOTES, IN THEIR ENTIRETY. THE CONTRACTOR MUST BE FAMILIAR WITH AND ACKNOWLEDGE FAMILIARITY WITH ALL OF THE GENERAL NOTES AND ALL OF THE PLANS' SPECIFIC NOTES. 13. THE CONTRACTOR'S PRICE FOR WATER SERVICE MUST INCLUDE ALL FEES, COSTS AND APPURTENANCES REQUIRED BY THE UTILITY TO PROVIDE FULL AND COMPLETE WORKING SERVICE. 14. SEWERS CONVEYING SANITARY FLOW, COMBINED SANITARY AND STORMWATER FLOW, OR INDUSTRIAL FLOW MUST BE SEPARATED

Page 9

AND APPURTENANCES REQUIRED BY THE UTILITY TO PROVIDE FULL AND COMPLETE WORKING SERVICE. 14. SEWERS CONVEYING SANITARY FLOW, COMBINED SANITARY AND STORMWATER FLOW, OR INDUSTRIAL FLOW MUST BE SEPARATED FROM WATER MAINS BY A DISTANCE OF AT LEAST 10 FEET HORIZONTALLY. IF SUCH LATERAL SEPARATION IS NOT POSSIBLE, THE PIPES MUST BE IN SEPARATE TRENCHES WITH THE AT LEAST 18 INCHES BELOW THE BOTTOM OF THE WATER MAIN, OR SUCH OTHER SEPARATION AS APPROVED BY THE GOVERNMENTAL AGENCY WITH JURISDICTION OVER SAME. WHERE APPROPRIATE SEPARATION FROM A WATER MAIN IS NOT POSSIBLE, THE SEWER MUST BE ENCASED IN CONCRETE, OR CONSTRUCTED OF DUCTILE IRON PIPE USING MECHANICAL OR SLIP-ON JOINTS FOR A DISTANCE OF AT LEAST 10 FEET ON EITHER SIDE OF THE CROSSING. IN ADDITION, ONE FULL LENGTH OF SEWER PIPE SHOULD BE LOCATED SO BOTH JOINTS WILL BE AS FAR FROM THE WATER LINE AS POSSIBLE. WHERE A WATER MAIN CROSSES UNDER A SEWER, ADEQUATE STRUCTURAL SUPPORT FOR THE SEWER MUST BE PROVIDED. 15. WHEN THESE PLANS INVOLVE MULTIPLE BUILDINGS, SOME OF WHICH MAY BE BUILT AT A LATER DATE, THE CONTRACTOR MUST EXTEND ALL LINES, INCLUDING BUT NOT LIMITED TO STORM, SANITARY, UTILITIES, AND IRRIGATION LINES, TO A POINT AT LEAST FIVE (5) FEET BEYOND THE PAVED AREAS FOR WHICH THE CONTRACTOR IS RESPONSIBLE. THE CONTRACTOR MUST CAP ENDS AS APPROPRIATE, MARK LOCATIONS WITH A 2X4 STAKE, AND MUST NOTE THE LOCATION OF ALL OF THE ABOVE ON A CLEAN COPY OF THE PLAN, WHICH THE CONTRACTOR MUST PROMPTLY PROVIDE TO THE OWNER IMMEDIATELY UPON THE COMPLETION OF WORK. 16. STORM AND SANITARY PIPE LENGTHS INDICATED ARE NOMINAL AND ARE MEASURED FROM CENTER OF INLET AND/OR MANHOLES STRUCTURE TO CENTER OF STRUCTURE. 17. THE CONTRACTOR MUST NOTIFY, IN WRITING, THE MUNICIPAL ENGINEER AT LEAST THREE (3) BUSINESS DAYS PRIOR TO INSTALLATION OF SANITARY COMPONENTS. FAILURE TO HAVE SANITARY INSTALLATION AND TESTING OBSERVED BY THE DESIGNATED ENGINEER MAY REQUIRE RE-EXCAVATION OF SANITARY LINE, AND RE-TESTING, WHICH WILL BE DONE AT THE CONTRACTOR'S SOLE COST AND EXPENSE. 18. SEWERS CROSSING STREAMS AND/OR LOCATION WITHIN 10 FEET OF THE STREAM EMBANKMENT, OR WHERE SITE CONDITIONS SO INDICATE, MUST BE CONSTRUCTED OF REINFORCED CONCRETE, DUCTILE IRON OR OTHER SUITABLE MATERIAL. 19. SANITARY PIPE MUST BE POLYVINYL CHLORIDE (PVC) SDR 35 EXCEPT WHERE CLEARLY INDICATED OTHERWISE. 20. FOR PIPES LESS THAN 12 FEET DEEP: POLYVINYL CHLORIDE

Page 9

E, DUCTILE IRON OR OTHER SUITABLE MATERIAL. 19. SANITARY PIPE MUST BE POLYVINYL CHLORIDE (PVC) SDR 35 EXCEPT WHERE CLEARLY INDICATED OTHERWISE. 20. FOR PIPES LESS THAN 12 FEET DEEP: POLYVINYL CHLORIDE (PVC) SDR 35 PER ASTM D3034. 21. FOR PIPES GREATER THAN 12 FEET DEEP: POLYVINYL CHLORIDE (PVC) SDR 26 PER ASTM D3034. 22. SANITARY LATERAL MUST BE PVC SCHEDULE 40 OR PVC SDR 26 UNLESS CLEARLY INDICATED OTHERWISE. 23. UNLESS CLEARLY INDICATED OTHERWISE, ALL STORM PIPES MUST BE REINFORCED CONCRETE PIPES (RCP) CLASS III WITH SILT/SOIL TIGHT JOINTS. WHEN HIGH-DENSITY POLYETHYLENE PIPE (HDPE) IS CALLED FOR ON THE PLANS, IT MUST CONFORM TO AASHTO M252 FOR PIPES 4" TO 10" AND TO AASHTO M294 FOR PIPES 12" TO 60" AND TYPE S (SMOOTH INTERIOR WITH ANGULAR CORRUGATIONS) WITH GASKET FOR SILT/SOIL TIGHT JOINT. PIPE FOR ROOF DRAIN CONNECTION MUST BE HDPE SDR 26 OR PVC SCHEDULE 40 UNLESS INDICATED OTHERWISE. HDPE PIPE JOINT GASKETS MUST BE PROVIDED AND CONFORM TO ASTM F477. 24. WATER MAIN PIPING MUST BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS AND SPECIFICATIONS OF THE LOCAL WATER COMPANY. IN THE ABSENCE OF SUCH REQUIREMENTS, WATER MAIN PIPING MUST BE CEMENT-LINED DUCTILE IRON (DIP) MINIMUM CLASS 52 THICKNESS. ALL PIPE AND APPURTENANCES MUST COMPLY WITH THE APPLICABLE AWWA STANDARDS IN EFFECT AT THE TIME OF APPLICATION. 25. GAS METERS MUST BE PROTECTED BY BOLLARDS AND FENCES IF INSTALLED WITHIN THE EXTERIOR OF THE BUILDING AS REQUIRED BY THE JURISDICTIONAL GAS PURVEYOR.

Page 10

SOUTH BRANCH RAHWAY RIVER BLOCK 157 LOT 5 N/F LANDS OF DIENER MT. PLEASANT ASSOCIATES LTD D.B. 12518, PG. 3496 BLOCK 157 LOT 8.03 BLOCK 157 LOT 8.02 BLOCK 157 LOT 8.06 BLOCK 157 LOT 8.01 BLOCK 157 LOT 2 BLOCK 157 LOT 11 BLOCK 157 LOT 1 P.O.B. D.B. 12518, PG. 3496 BROOK PLACE MOUNT PLEASANT PLACE MOUNT PLEASANT AVENUE PLEASANT VALLEY WAY W E S SOUTH BRANCH RAHWAY RIVER SOUTH BRANCH RAHWAY RIVER LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW LOW FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA FHA EXISTING BUILDING TO REMAIN PROP RETAIL SPACE (± 17,245 SF FIRST FLOOR) (± 1,522 SF MEZZANINE) 187 PARKING STALLS APPROX LOCATION OF PROP LIMIT OF WORK APPROX LOCATION OF PROP SAWCUT LINE AND PAVEMENT REPAIR STRIP, AS REQUIRED LIMIT OF PROP MILL AND OVERLAY PAVEMENT (TYP) LIMIT OF PROP MILL AND OVERLAY PAVEMENT (TYP) LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD PROP. INLET FILTER (TYP) DuuB DunC PROP MILL AND OVERLAY PAVEMENT TO BE USED AS CONSTRUCTION ENTRANCE APPROX LOCATION OF PROP LIMIT OF WORK FHA ELEVATION = 369.9 FT BASED ON METHOD 3 DELINEATION TPF TREE PROTECTION FENCE APPROX LOCATION OF PROP SAWCUT LINE AND PAVEMENT REPAIR STRIP, AS REQUIRED EXIST SOIL DELINEATION LINE PER WEB SOIL SURVEY (TYP) TEMPORARY SOIL STOCKPILE (TYP) LOD LOD LOD LIMIT OF DISTURBANCE SF. (28,390 0.65 AC.) PROP. HAY BALE SEDIMENT BARRIER PROP. STABILIZED CONSTRUCTION ENTRANCE (TYP) SF SF SF SF SF SF SF D D D 369 374 373 372 371 370 368 375 369 369 370 PROP PERVIOUS PAVEMENT STONE STORAGE TOP ELEV. = 367.65 100 YEAR FUT. STORM ELEV. = 367.26 100 YEAR CUR. STORM ELEV. = 367.21 10 YEAR FUT. STORM ELEV. = 367.15 10 YEAR CUR. STORM ELEV. = 367.13 2 YEAR FUT. STORM ELEV. = 367.09 2 YEAR CUR. STORM ELEV. = 367.07 WQ STORM

Page 10

. STORM ELEV. = 367.26 100 YEAR CUR. STORM ELEV. = 367.21 10 YEAR FUT. STORM ELEV. = 367.15 10 YEAR CUR. STORM ELEV. = 367.13 2 YEAR FUT. STORM ELEV. = 367.09 2 YEAR CUR. STORM ELEV. = 367.07 WQ STORM ELEV. = 366.95 STONE STORAGE BOTTOM ELEV. = 366.65 EST. SHWT = +/- 363.00 FFE: 370.10 MH-130 PROP MH RIM 368.25 INV IN 364.42 (15") MH-120 INV OUT 364.42 (15") PROP C/O-150 INV. (OUT): 366.67 PROP C/O-160 INV. (OUT): 366.65 PROP C/O-170 INV. (OUT): 366.52 PROP C/O-180 INV. (OUT):366.16 PROP C/O-190 INV. (OUT): 366.04 PROP C/O-210 INV. (IN): 365.93 (6") INV. (IN): 365.76 (8") INV. (OUT): 365.76 (8") PROP C/O-250 INV. (IN): 366.79 INV. (OUT): 366.79 PROP C/O-240 INV. (OUT): 366.96 PROP C/O-230 INV. (IN): 367.07 INV. (OUT): 367.07 PROP C/O-220 INV. (OUT): 367.10 OS-110 PROP OUTLET STRUCTURE RIM: 368.32 WEIR: 366.95 (4') INV. (IN): 365.60 (6") INV. (OUT): 365.43 (15") PROP 6" INSPECTION PORT INV. (OUT): 365.90 PROP 6" INSPECTION PORT INV. (IN): 365.67 INV. (OUT): 365.67 PROP 6" INSPECTION PORT INV. (IN): 365.78 INV. (OUT): 365.78 PROP 6" INSPECTION PORT INV. (OUT): 365.92 MH-120 PROP MH RIM: 368.44 INV. (IN): 365.71 (8") INV. (IN): 365.18 (15") INV. (OUT): 365.18 (15") PROP. CONNECTION TO EXIST STM SYSTEM INV. (IN): 364.15 (15") PROP 6" INSPECTION PORT INV. (OUT): 365.87 369 HATCH LEGEND PROP FULL DEPTH ASPHALT PAVEMENT PROP PERVIOUS ASPHALT PAVEMENT PROP MILL AND OVERLAY PAVEMENT PROP CONCRETE SIDEWALK PROP HEAVY-DUTY CONCRETE PAVEMENT PROP CONCRETE PAVEMENT LEGEND PROPERTY LINE TOP OF BANK 50 FT NJDEP RIPARIAN BUFFER WIDTH WETLAND BOUNDARY 50 FT WETLAND BUFFER WIDTH FHA ELEVATION (BASED ON METHOD 3 DELINEATION) FHA THIS PLAN TO BE UTILIZED FOR SOIL EROSION AND SEDIMENT CONTROL PURPOSES ONLY. SF LOD TPF LIMIT OF DISTURBANCE LINE HAS BEEN OFFSET FOR GRAPHICAL PURPOSES. ACTUAL LIMIT OF DISTURBANCE WILL OCCUR AT THE SILT FENCE OR LIMIT OF GRADING. 0 SCALE: 1" = 30' 30 307.515 C-801 SOIL EROSION AND SEDIMENT CONTROL PLAN SF SF SF SF SF DC DuuB LEGEND PROPOSED INLET FILTER SILT FENCE LIMIT OF DISTURBANCE TREE PROTECTION FENCE CONSTRUCTION ENTRANCE DUST CONTROL TEMPORARY STOCK PILE DUNELLEN - URBAN LAND 3 TO 8 PERCENT SLOPES HSG: A DUNELLEN SANDY LOAM 8 TO 15 PERCENT SLOPES HSG: A DunC PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PROP-NJA230139.00-1A----->LAYOUT: C-801 EROS TH THIS

Page 10

PES HSG: A DunC PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: PROJECT: FOR G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-PROP-NJA230139.00-1A----->LAYOUT: C-801 EROS TH THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. SHEET NUMBER: SHEET TITLE: NJA230139.00-1A CRA / TGH TXL 08/14/2025 P-CIVL-PROP PRELIMINARY & FINAL MAJOR SITE PLAN PROPOSED RETAIL STORE MAP: 87 | BLK: 157 | LOT: 5 457 MOUNT PLEASANT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY 1 REVISION 1 - REVISIONS REV DATE COMMENT DRAWN BY CHECKED BY 09/17/2025 REV. PER SCD COMMENTS. TGH TXL 09/17/2025 ISSUED FOR MUNICIPAL & AGENCY REVIEW & APPROVAL 30 INDEPENDENCE BLVD., SUITE 200 WARREN, NJ 07059 Phone: (908) 668-8300 Fax: (908) 754-4401 www.BohlerEngineering.com NJ CERT. OF AUTHORIZATION NO. 24GA28400600 & MH000122 BOHLER ENGINEERING NJ, LLC TM THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES TM BOHLER Sep 24, 2025 NEW JERSEY YOU MUST CALL 811 BEFORE ANY EXCAVATION WHETHER IT'S ON PRIVATE OR PUBLIC LAND. 1-800-272-1000 www.nj1-call.org Know what's below. Callbefore you dig. PROFESSIONAL ENGINEER T. LAM NEW JERSEY LICENSE No. 47863 NEW YORK LICENSE No. 092942 CONNECTICUT LICENSE No. 30024 PENNSYLVANIA LICENSE No. 76746 SESC COMPACTION NOTE THE SUBJECT SITE IS LOCATED IN PLANNING AREA-1 AND IS DEVELOPED UNDER EXISTING CONDITIONS. BASED ON THE NEW JERSEY DEPARTMENT OF AGRICULTURE STATE SOIL CONSERVATION COMMITTEE TECHNICAL BULLETIN, EFFECTIVE MARCH 2018, THE SOIL COMPACTION REQUIREMENTS ARE NOT APPLICABLE. SOIL EROSION & SEDIMENT CONTROL PLAN NOTES (Rev. 12/2024) 1. EROSION CONTROL MEASURES MUST CONFORM TO THE GUIDELINES FOR EROSION AND SEDIMENT CONTROL UNLESS OTHERWISE NOTED, OR UNLESS ENGINEER CLEARLY AND SPECIFICALLY, IN WRITING, DIRECTS OTHERWISE. INSTALLATION OF EROSION CONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION CONTROL CONSTRUCTION NOTES. 2. THE FOLLOWING EROSION CONTROL

Page 10

WRITING, DIRECTS OTHERWISE. INSTALLATION OF EROSION CONTROL, CLEARING, AND SITE WORK MUST BE PERFORMED EXACTLY AS INDICATED IN THE EROSION CONTROL CONSTRUCTION NOTES. 2. THE FOLLOWING EROSION CONTROL MEASURES ARE PROPOSED FOR THIS SITE: a. STABILIZE CONSTRUCTION ENTRANCE/ EXIT - A TEMPORARY STONE CONSTRUCTION ACCESS IS TO BE INSTALLED AT THE DESIGNATED LOCATION AS SHOWN ON THE PLAN. THIS AREA MUST BE GRADED SO THAT RUNOFF WATER WILL BE RETAINED ON-SITE. b. SILT FENCE - INSTALL SILT FENCE(S) AROUND ALL OF THE DOWNSLOPE PERIMETERS OF THE SITE, TEMPORARY FILL AREAS, AND SOIL STOCKPILES. c. INLET PROTECTION - IN ORDER TO REDUCE THE POTENTIAL FOR SEDIMENT TO ENTER THE STORMWATER SYSTEM, THE CONTRACTOR SHALL INSTALL INLET PROTECTION AROUND EACH INLET AS DRAINAGE STRUCTURES ARE INSTALLED. INSTALL TEMPORARY INLET PROTECTION ON INLETS DOWNSLOPE FROM DISTURBANCE, WHICH MAY BE BEYOND THE LIMITS OF DISTURBED AREA. d. TREE PROTECTION FENCE – THROUGH THE USE OF TREE PROTECTION FENCE, THE CONTRACTOR MUST MARK ALL EXISTING TREES AND SHRUBS WITHIN AND AROUND THE WORK AREA THAT ARE TO REMAIN. THE CONTRACTOR SHALL REFER TO THE TREE PROTECTION FENCE DETAILS HEREIN. e. SOIL STOCKPILES – STOCKPILES SHALL BE LIMITED TO 35’ MAX. HEIGHT AND SHOULD BE REMOVED OR UTILIZED FOR SITE CONSTRUCTION AS SOON AS PRACTICABLE. f. DUST CONTROL –SHOULD EXCESSIVE DUST BE GENERATED, THE CONTRACTOR MUST PROMPTLY USE AND APPLY WATER TO BARE SOIL SURFACES TO ELIMINATE, OR IF NOT POSSIBLE, MINIMIZE, BLOWING DUST. g. DEWATERING – THE CONTRACTOR MUST PERFORM DEWATERING IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS AND APPROVED PERMITS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO OBTAIN AND PAY THE COSTS ASSOCIATED WITH ANY AND ALL NECESSARY DISCHARGE PERMITS ASSOCIATED WITH SAME. h. CONSTRUCTION WASTE MATERIAL STORAGE – THE CONTRACTOR MUST LOCATE CONSTRUCTION WASTE MATERIAL STORAGE AREAS TO MINIMIZE EXPOSURE TO STORMWATER. CONTRACTOR MUST IMMEDIATELY PLACE CONSTRUCTION WASTE IN ON-SITE STORAGE CONTAINERS UNTIL THAT CONSTRUCTION WASTE IS READY FOR OFF-SITE DISPOSAL. CONTRACTOR MUST MAINTAIN SPILL PREVENTION & RESPONSE EQUIPMENT AND MAKE SAME CONTINUOUSLY AVAILABLE ON-SITE FOR USE BY CONTRACTOR'S EMPLOYEES WHO MUST BE PROPERLY TRAINED IN THE APPLICATION OF SPILL PREVENTION & RESPONSE PROCEDURES. 3. THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. CONTRACTOR MUST IMMEDIATELY CLEAR ANY

Page 10

PLOYEES WHO MUST BE PROPERLY TRAINED IN THE APPLICATION OF SPILL PREVENTION & RESPONSE PROCEDURES. 3. THE CONTRACTOR MUST INSPECT EROSION CONTROL MEASURES WEEKLY. CONTRACTOR MUST IMMEDIATELY CLEAR ANY SILT GREATER THAN BEHIND THE FILTER FABRIC AND/OR SILT SOCK BARRIERS AND EXCAVATE AND REMOVE ANY SILT FROM DROP INLET PROTECTION. 4. THE TERM 'PERMANENT STABILIZATION' USED THROUGHOUT THIS SEQUENCE IS MEANT TO DESCRIBE THE PROPER PLACING, GRADING, CONSTRUCTING, REINFORCING, LINING, AND COVERING OF SOIL, ROCK, OR EARTH TO ENSURE THEIR PERMANENT RESISTANCE TO EROSION, SLIDING OR OTHER MOVEMENT. FOR AN EARTH DISTURBANCE TO BE PERMANENTLY STABILIZED, THE DISTURBED AREA SHALL BE COVERED WITH ONE OF THE FOLLOWING: A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER, WITH A DENSITY CAPABLE OF RESISTING ACCELERATED EROSION AND SEDIMENTATION; OR AN ACCEPTABLE BMP THAT PERMANENTLY MINIMIZES ACCELERATED EROSION AND SEDIMENTATION. 5. BEFORE INITIATING ANY REVISION TO THE APPROVED EROSION AND SEDIMENT CONTROL PLAN OR REVISIONS TO OTHER PLANS WHICH MAY AFFECT THE EFFECTIVENESS OF THE APPROVED E&S CONTROL PLAN, THE OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS FROM THE CONSERVATION DISTRICT. THE OPERATOR SHALL ASSURE THAT THE APPROVED EROSION AND SEDIMENT CONTROL PLAN IS PROPERLY AND COMPLETELY IMPLEMENTED. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST MANAGEMENT PRACTICES TO ELIMINATE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT POLLUTION. 6. THE CONTRACTOR MUST APPLY TEMPORARY SEED AND MULCH TO ALL DISTURBED AREAS THAT WILL NOT BE BROUGHT TO FINISHED GRADE AND VEGETATED WITHIN DAYS. WHEN AREAS ARE DISTURBED AFTER THE GROWING SEASON, THE CONTRACTOR MUST STABILIZE SAME WITH GEOTEXTILE FABRIC AND MAINTAIN SAME IN STRICT ACCORDANCE WITH BEST MANAGEMENT PRACTICES. 7. AS SOON AS SLOPES, CHANNELS, DITCHES, AND OTHER DISTURBED AREAS REACH FINAL GRADE, THEY MUST BE STABILIZED. WHEN FINAL GRADE IS ACHIEVED DURING NON-GERMINATING MONTHS, THE AREA SHOULD BE MULCHED UNTIL THE BEGINNING OF THE NEXT PLANTING SEASON. AS DISTURBED AREAS WITHIN A PROJECT APPROACH FINAL GRADE, PREPARATIONS SHOULD BE MADE FOR SEEDING AND MULCHING TO BEGIN (I.E., ANTICIPATE THE COMPLETION DATE AND SCHEDULE THE SEEDER). IN NO CASE SHOULD AN AREA EXCEEDING 15,000 SQUARE FEET, WHICH IS