Show all pagesOPENING WIDTH OF 32 INCHES (813 MM). THE CLEAR FROM TABLE 7.21.1 MAXIMUM ALLOWABLE TRAVEL DISTANCE (TABLE 1017.2) OCCUPANT LOADS (TABLE 1004.1.2) OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (1.57 RAD). MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES SEE LIFE SAFETY PLAN SHEETS A1.XX - A1.XX 713.4 FIRE-RESISTANCE RATING OCCUPANCY WITHOUT WITH SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIES OR MORE, AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN 1010.1.1.1 PROJECTIONS INTO CLEAR OPENING SPRINKLERED CLASSIFICATION SPRINKLER SPRINKLER USE GROUP OCCUPANCY PER SQ. FT. DOB APPROVAL STAMP: FOUR STORIES. THE NUMBER OF STORIES CONNECTED BY THE SHAFT ENCLOSURE SHALL INCLUDE ANY
OCCUPANCY PER SQ. FT. DOB APPROVAL STAMP: FOUR STORIES. THE NUMBER OF STORIES CONNECTED BY THE SHAFT ENCLOSURE SHALL INCLUDE ANY THERE SHALL NOT BE PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 CLASSIFICACION OCCUPANCY N° OF PERSONS WATER CLOSETS SEE LAVATORIES M 200 FT. 250 FT. MERCANTILE 60 GROSS BASEMENTS BUT NOT ANY MEZZANINES. SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING INCHES (864 MM) ABOVE THE FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (864 MM) AND 80 INCHES (2032 MM) ABOVE THE FLOOR OR GROUND SHALL NOT GROUP OF EACH SEX (5) FOR URINALS NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED, BUT NEED NOT EXCEED 2 HOURS. SHAFT S-2 300 FT. 400 FT. STORAGE 300 GROSS ENCLOSURES SHALL MEET THE REQUIREMENTS OF SECTION 703.2.1.1. EXCEED 4 INCHES (102 MM). MALE FEMALE MALE FEMALE 715.3 FIRE-RESISTANCE-RATED ASSEMBLY INTERSECTIONS 1010.1.2.1 DIRECTION OF SWING MERCANTILE (M) M: STORES, 50 OR LESS 1 1 1 1
M) M: STORES, 50 OR LESS 1 1 1 1 SHOPS, MAXIMUM ALLOWABLE EGRESS CAPACITIES (SECTION 1005) JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE-RATED WALLS, FLOOR OR FLOOR/CEILING SIDE-HINGED SWINGING DOORS, PIVOTED DOORS AND BALANCED DOORS SHALL SWING IN THE ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED FIRE- DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA CONTAINING AN OCCUPANT LOAD MARKETS 51 - 151 ADD 1 ADD 1 ADD 0 ADD 0 OF 50 OR MORE PERSONS OR A GROUP H OCCUPANCY. ELEMENT MINIMUM ALLOWED MINIMUM ACTUAL EGRESS WITH PER DOOR CALCULATIONS RESISTANT JOINT SYSTEM DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS CLEAR WITH (IN.) CLEAR WITH (IN.) OCCUPANT (IN.) (SECTION 1005.3.2 & 1010.1.1) THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN OR BETWEEN WHICH OCCUPANT LOAD CALCULATION: THE SYSTEM IS INSTALLED. 1010.1.5 LANDINGS AT DOORS FIRST FLOOR - MERCANTILE (M)
1010.1.5 LANDINGS AT DOORS FIRST FLOOR - MERCANTILE (M) (INCLUDING ACCESORY USE) = 246 LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, STAIRS 44 SECTION 1011.2 44 # 0.3 36" DOOR (42 IN. - 3 IN.) / .2 IN. = 165 OCCUPANTS WHICHEVER IS GREATER. DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED CORRIDORS 44 SECTION 1020.3 44 # 0.2 36" DOOR (36 IN. - 3 IN.) / .2 IN. = 165 OCCUPANTS DIMENSION BY MORE THAN 7 INCHES (178 MM). WHERE A LANDING SERVES AN OCCUPANT LOAD OF 50 TOTAL NUMBER OF FIXTURES REQUIRED OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF ITS LAVATORIES : 2(M) = 2 DOOR (SINGLE) 32 SECTION 1010.1 36" DOOR # 0.2 36" DOOR (34 IN. - 3 IN.) / .2 IN. = 165 OCCUPANTS REQUIRED WIDTH. LANDINGS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT WATER CLOSETS : 4(M) = 6 COPYRIGHT © JORGE MASTROPIETRO ATELIER ARCHITECTS
COPYRIGHT © JORGE MASTROPIETRO ATELIER ARCHITECTS LESS THAN 44 INCHES (1118 MM). DOORS (PAIR) 64 SECTION 1010.1 PAIR 36" DOORS # 0.2 72" DOOR (72 IN. - 6 IN.) / .2 IN. = 330 OCCUPANTS