Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · May 6, 2026

13026 Resubmission

Preserved file SHA-2560e7392dd7d594406a7ef76abd40438d954e383491ee5ec94505f00a12f9db01d

Indexed text

Page 26

JENNIFER PALERMO THE SAME STUD CAVITY. ANY OPENING FOR SUCH FIXTURES AND FOR PIPING OUTLETS BETWEEN THE HOUSING AND INTERIOR WALL OR CEILING COVERING. ALM ALARM CNTR COUNTER EXH FN EXHAUST FAN AIR CONDITIONING MULT MULTIPLE REINF REINFORCEMENT TOS TOP OF SLAB NJ LICENSE NO. AI 015932 SHALL BE CUT TO THE PROPER SIZE AND SEALED. ELECTRICAL DEVICES SHALL BE ALT ALTERNATE CO CLEANOUT EXP EXPOSED HW HOT WATER MVBL MOVABLE REM REMOVABLE TOT TOTAL INSTALLED IN FULL BOXES AND SEALED WITH A NON-HARDENING SEALANT, SUCH AS 3M F. THE FOLLOWING SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE AMB AMBIENT COL COLUMN EXPN EXPANSION HWH HOT WATER HEATER N NORTH REQD REQUIRED TOW TOP OF WALL BRAND FIRE BARRIER, MPP-4S MOLDABLE PUTTY PAD OR EQUAL. SEALED WITH AN AIR BARRIER MATERIAL, SUITABLE FILM OR SOLID MATERIAL. ROCK WOOL AMPL AMPLIFIER COMPL COMPLETE EXSP EXPOSED HYD HYDRANT NA NOT APPLICABLE RESIL RESILIENT TRNBKL TURNBUCKLE AMT AMOUNT CONC FL CONCRETE FLOOR EXST GR EXISTING GRADE IF INSIDE FACE NEG

Page 26

AMT AMOUNT CONC FL CONCRETE FLOOR EXST GR EXISTING GRADE IF INSIDE FACE NEG NEGATIVE RFM RECESSED FLOOR MAT TS TENSILE STRENGTH PROJECT: AND FIBERGLAS BATT INSULATION ARE NOT ACCEPTABLE AS AN AIR BARRIER MATERIAL. E. THE ENTIRE PERIMETER OF AN ACOUSTICAL ASSEMBLY SHALL BE MADE AIRTIGHT TO ANN ANNUNCIATOR CONC CONCRETE EXT EXTERIOR INCAND INCANDESCENT NF NEAR FACE RFG ROOFING TV TELEVISION PREVENT SOUND TRANSMISSION THROUGH THE ASSEMBLY AND PREVENT SOUND ANOD ANODIZED CONF CONFERENCE EXTN EXTENSION INL INLET NIC NOT IN CONTRACT RH RIGHT HAND TYP TYPICAL 262-270 MAIN STREET AIR SEAL THE FOLLOWING LOCATIONS BEFORE INSULATION: FLANKING AROUND THE ASSEMBLY AND THROUGH ASSEMBLY PENETRATIONS. FLEXIBLE 1. MUD SILL TO FOUNDATION. ANT ANTENNA CONN CONNECTION F BRK FIRE BRICK INSTL INSTALLATION NO NUMBER RHR RIGHT HAND REVERSE UFD UNDER FLOOR DUCT

Page 26

ION F BRK FIRE BRICK INSTL INSTALLATION NO NUMBER RHR RIGHT HAND REVERSE UFD UNDER FLOOR DUCT WEST ORANGE SEALANT OR AN ACOUSTICAL GASKET SHALL BE USED TO SEAL BETWEEN THE STC RATED 2. RIM JOIST TO MUD SILL. AP ACCESS PANEL CONSTR CONSTRUCTION F/F FACE TO FACE INSUL INSULATION NOM NOMINAL RND ROUND UGND UNDERGROUND ESSEX COUNTY, NJ 07052 ASSEMBLY AND ALL DISSIMILAR SURFACES AND ALSO BETWEEN THE ASSEMBLY AND APPX APPENDIX CONT CONTINUOUS FBD FIBERBOARD INT INTERIOR NS NEAR SIDE RO ROUGH OPENING UL UNDERWRITERS LABORATORY SIMILAR SURFACES WHERE PERIMETER RELIEF IS REQUIRED. THE SPACING AND NUMBER 3. TOP PLATE TO RIM JOIST BETWEEN CONDITIONED STORIES. ARCH ARCHITECT (URAL) CONTR CONTRACTOR FD FLOOR DRAIN INV INVERT NTS NOT TO SCALE RV ROOF VENT ULT ULTIMATE BLOCK 114 LOT 50 & 55 4. SUBFLOOR SHEATHING TO RIM JOIST BETWEEN CONDITIONED STORIES. OF MECHANICAL FASTENERS IS ALSO OF GREAT IMPORTANCE IN ACHIEVING A LISTED STC ASC ABOVE SUSPENDED CEILING COORD COORDINATE FDN FOUNDATION INV EL INVERT ELEVATION O/O OUT TO OUT RVS REVERSE UNEX UNEXCAVATED

Page 26

FOUNDATION INV EL INVERT ELEVATION O/O OUT TO OUT RVS REVERSE UNEX UNEXCAVATED 5. SUBFLOOR SHEATHING T&G AND SQUARE EDGE JOINTS. ASPH ASPHALT COV PL COVER PLATE OR IIC RATING. FEC FIRE EXTINGUISHER CABINET JAN JANITOR OA OVERALL S SOUTH UNFIN UNFINISHED 6. PARTITION WALL STUDS AT EXTERIOR WALL INTERSECTIONS. 7. TOP PLATES OF EXTERIOR STUD WALLS BETWEEN CONDITIONED STORIES. ASYM ASYMMETRICAL CPRS COMPRESSIBLE FGL FIBERGLASS JC JANITOR'S CLOSET OC ON CENTER SALV SALVAGE UNO UNLESS NOTED OTHERWISE OWNER: AV AUDIO VISUAL CPT CARPET FIN GR FINISH GRADE JST JOIST OD OUTSIDE DIAMETER SB SPLASH BLOCK UPS UNINTERRUPTED. POWER SUPPLY 262 MAIN STREET F. PERIMETER SEALS IN WALL ASSEMBLIES: IN ORDER TO BE EFFECTIVE FOR THE LIFE OF THE 8. DROPPED CEILINGS, SOFFITS AND CHASES. AVE AVENUE CRCMF CIRCUMFERENCE FIN FL FINISH FLOOR JT JOINT OF OUTSIDE FACE

Page 26

AVE AVENUE CRCMF CIRCUMFERENCE FIN FL FINISH FLOOR JT JOINT OF OUTSIDE FACE SC SOLID CORE UR URINAL BUILDING, SEALANTS MUST BE RESILIENT AND NON-HARDENING. STANDARD WEATHER 9. ATTIC KNEEWALLS AND JOIST CAVITIES UNDER ATTIC KNEEWALLS. B&B BALLED AND BURLAPPED CRS COLD ROLLED STEEL FIN FINISH KB KNEE BRACE OFCI OWNER FURNISHED/ SCHED SCHEDULE UTIL UTILITY REALTY LLC CAULKING IS UNSATISFACTORY AS AN ACOUSTICAL SEALANT, SINCE IT TENDS TO HARDEN 10.TUB/SHOWER ENCLOSURE TO SUBFLOOR. OVER TIME. PLACEMENT OF THE SEALANT IS CRITICAL. THE PURPOSE OF THE SEAL IS TO BAF BAFFLE CSG CASING FL FLASHING KO KNOCKOUT CONTRACTOR INSTALLED SCMU SOLID CMU V VOLT 262-270 MAIN STREET 11.MASONRY FIREPLACE TO SUBFLOOR. BAL BALANCE CSK COUNTERSUNK FLG FLANGE OFF OFFICE SCRN SCREEN PROVIDE A RESILIENT CLOSURE BETWEEN ONE SIDE OF AN ASSEMBLY AND THE OTHER, 12.ELECTRICAL SERVICE PANEL ON EXTERIOR WALL OR TENANT SEPARATION WALLS. BB BULLETIN BOARD CSMT CASEMENT FLR FLOOR KOP KNOCKOUT PANEL

Page 26

KOP KNOCKOUT PANEL VAC VACUUM WEST ORANGE, NJ 07052 KPL KICK PLATE OFOI OWNER FURNISHED/ SD STORM DRAIN VAV VARIABLE AIR VOLUME WHICH REDUCES THE POTENTIAL FOR FLANKING NOISE TRANSMISSION. THE PREFERRED 13.HVAC DUCT JOINTS AND SEAMS SEALED WITH MASTIC. BC BACK OF CURB CSWK CASEWORK FLR SK FLOOR SINK KWY KEYWAY OWNER INSTALLED SECT SECTION VB VINYL BASE 646 427 9908 PROCEDURE IS TO INSTALL THE GYPSUM WALL BOARD WITH A MINIMUM 1/4" GAP BETWEEN 14.REGISTER BOOTS SEALED TO SUBFLOOR. BD BOARD CT CERAMIC TILE FLR PL FLOOR PLATE OPNG OPENING SGL SINGLE VCT VINYL COMPOSITION TILE L LEFT THE ADJACENT CEILING GYPSUM PANEL AND ALSO AT THE SUBFLOOR. SEALANT SHOULD 15.EXHAUST VENTILATION DUCT JOINTS AND SEAMS SEALED WITH MASTIC. BEV BEVEL CTV CABLE TELEVISION FLR FIN FLOOR FINISH LAB LABORATORY OPP OPPOSITE SHR SHOWER VERT VERTICAL BE

Page 26

SION FLR FIN FLOOR FINISH LAB LABORATORY OPP OPPOSITE SHR SHOWER VERT VERTICAL BE APPLIED TO FILL THE PERIMETER GAP BETWEEN THE GYPSUM WALL BOARD AND THE 16.WIRING PENETRATIONS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. BF BOTH FACES CUB CUBICLE FLT GL FLOAT GLASS OPT OPTIONAL SHTHG SHEATHING CONSULTANTS: LAV LAVATORY VEST VESTIBULE SURROUNDING FLOOR, WALL AND CEILING COMPONENTS. CAULKING SHOULD NOT BE BFF BELOW FINISH FLOOR CUR CURRENT PLACED BENEATH THE SILL PLATE OR RUNNER TRACK OF A WALL ASSEMBLY. 17.WIRING INTO ELECTRICAL BOXES. FLUOR FLUORESCENT LB POUND ORD OVERFLOW ROOF DRAIN SHVL SHELVES VIB VIBRATION TRAFFIC ENGINEER 18.PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD

Page 26

VIBRATION TRAFFIC ENGINEER 18.PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. BFP BACKFLOW PREVENTER CW COLD WATER FOC FACE OF CONCRETE LBR LUMBER ORIG ORIGINAL SIM SIMILAR VNR VENEER 19.BATH AND SHOWER DRAINS TO SUBFLOOR. BITUM BITUMINOUS DBL GLZ DOUBLE GLAZING FOM FACE OF MASONRY LCMU LIGHTWEIGHT CMU OVHD OVERHEAD SJ SLIP JOINT VOL VOLUME DOLAN&DEAN G. INSULATION INDICATED TO BE PROVIDED IN A WALL ASSEMBLY SHALL BE THE SAME DEPTH BJT BED JOINT DEPT DEPARTMENT FOS FACE OF STUD LD BRG LOAD BEARING OXY OXYGEN SK SINK VR VAPOR RETARDER CONSULTING ENGINEERS, LLC AS THE WALL STUD FRAMING. UNLESS OTHERWISE REQUIRED BY CODE, REGULAR UN- AIR SEAL THE FOLLOWING LOCATIONS AFTER GYPSUM WALL BOARD INSTALLATION: BL BASE LINE DET DETAIL FPL FIREPLACE LDG LANDING P PAINT SLP SLOPE VT VINYL TILE 181 WEST HIGH STREET FACED GLASS FIBER OR MINERAL WOOL INSULATION IS ACCEPTABLE. DO NOT OVERSTUFF 1. PROVIDE 1/4" SEALANT AT GWB

Page 26

SLOPE VT VINYL TILE 181 WEST HIGH STREET FACED GLASS FIBER OR MINERAL WOOL INSULATION IS ACCEPTABLE. DO NOT OVERSTUFF 1. PROVIDE 1/4" SEALANT AT GWB TO SUBFLOOR AT EXTERIOR WALLS AND TENANT BLDG BUILDING DF DRINKING FOUNTAIN FPRF FIREPROOFING LF LINEAR FOOT PAR PARALLEL SLV SLEEVE VWC VINYL WALL COVERING THE INSULATION, AS THIS WILL REDUCE THE ACOUSTICAL PERFORMANCE OF THE SEPARATION WALLS. BLK BLOCK DFR DOOR FRAME FRM FRAME LG LENGTH PARG PARGING SM SHEET METAL W/ WITH SOMERVILLE, NJ 08876 ASSEMBLY. 2. DOOR FRAMES TO GWB AT EXTERIOR WALLS AND CORRIDOR WALLS. BLKG BLOCKING DH DOUBLE HUNG FRNT FRONT LH LEFT HAND PB PANIC BAR SMLS SEAMLESS W/W WALL TO WALL 908 927 0100 3. WINDOW FRAMES TO GWB AT EXTERIOR WALLS. BLKHD BULKHEAD DIM DIMENSION FS FINISHED SURFACE LHR LEFT HAND REVERSE PBD PARTICLEBOARD SP SPACING W/O WITHOUT H. RESILIENT METAL COMPONENTS - RESILIENT CHANNELS SHALL BE DIETRICH RC DELUXE

Page 26

CLEBOARD SP SPACING W/O WITHOUT H. RESILIENT METAL COMPONENTS - RESILIENT CHANNELS SHALL BE DIETRICH RC DELUXE BLST BALLAST DIST DISTANCE FSP FIRE STANDPIPE LIN LINEAR PC PORTLAND CEMENT SPCL SPECIAL W/R WATER RESISTANT STRUCTURAL ENGINEER 4. TUB/SHOWER ENCLOSURE TO GWB. RCSD. RESILIENT CHANNELS POSSESS A SPRING ACTION TO DECOUPLE AND ISOLATE THE 5. ATTIC AND CRAWLSPACE ACCESS COVERS TO GWB OR SUBFLOOR. BM BEAM DIV DIVIDER FSTNR FASTENER LIQ LIQUID PCP PORTLAND CEMENT SPEC SPECIFICATION W WEST HUDSON ENGINEERING, LLC. COMPONENTS THEY CONNECT, WHILE PROVIDING THE STRENGTH TO FIRMLY SUPPORT BP BASE PLATE DIW DEIONIZED WATER FTG FOOTING LKR LOCKER PED PEDESTAL SPKLR SPRINKLER WC WATER CLOSET 25 W8TH STREET, BSMT 6. ATTIC ACCESS PULL-DOWN STAIRS SEALED WITH WEATHERSTRIPPING ON COVER. THESE COMPONENTS. A CONCERN IN THE INSTALLATION OF GYPSUM BOARD ON RESILIENT BRCG BRACING DJ DOUBLE JOIST FURR FURRING LKR RM LOCKER ROOM PERF PERFORATED SPKR SPEAKER WD WOOD 7. RECESSED LIGHT HOUSING TO GWB.

File revisions (1)