PB 25 12 Application
99718697e29a016b4d2d11e4f87eeea35b359f5e29e7828aee737a34f535e855Indexed text
NJ PROFESSIONAL ENGINEER LIC. NO. GE54968 C1.12 SCALE: N.T.S. C1.12 SCALE: N.T.S. C1.12 SCALE: N.T.S. SCREW STAINLESS STEEL CLEAVIS HANGER CAP MARKED "SEWER" 12" THIS SECTION OF PIPE TO BE INSTALLED CURB OR CURBLINE TYPE PLUG SANITARY WHEN ORDERED BY THE ENGINEER. BUT SEWER MAIN GRADE
EWER MAIN GRADE ONLY AFTER THE TRENCH HAS BEEN FINISH GRADE SAWCUT HOLE IN EXISTING SEWER COMPLETELY BACKFILLED AND HAS HAD PROPOSED PIPE PVC PIPE 2' A A TIME TO SETTLE PLUG VARIES SECURE CASTING IN PLACE CAMPBELL FOUNDRY CASTING
VARIES SECURE CASTING IN PLACE CAMPBELL FOUNDRY CASTING 45° 4155 OR APPROVED EQUAL LATERAL PLAN WITH MORTAR AROUND ENTIRE PERIMETER OF CASTING T-WYE NON-SHRINK, 8" (CLEANOUT) PROPERTY NON-METALLIC BEYOND THIS POINT 45° WYE 1" CLEAR AROUND PVC BY
1" CLEAR AROUND PVC BY OTHERS IN GROUT MUST BE 8" PLAN FILLED IN BETWEEN ACCORDANCE WITH 12" CURBLINE CONCRETE CONCRETE GRADE LINE LATERAL AND BRICK EXISTING BRICK 3 LOCAL CODES. (CHISEL "S" IN CURB AT ENCASEMENT SEWER (SIZE COLLAR SHALL BE CLASS 4" Ø CLEAN CRUSHED GRADE SERVICE LATERAL) WALL "B" CONC. 5-7% AIR STONE 45° WYE AND SHAPE 11" BRANCH
11" BRANCH PVC PIPE 5'-0" MINIMUM VARIES) ENTRAINED (TYP) SUBGRADE COMPACTED PVC PIPE COVER INFILL DOWN 45° BEND (SUPPORT AGAINST NOTES: TO 95% MODIFIED (CLEANOUT) SHEETING WHICH IS TO 4" Ø CLEANOUT 1. MAXIMUM DISTANCE SDR 35 PVC PROCTOR TO BE LEFT IN PLACE) SUBGRADE
E) SUBGRADE (SEE DETAIL) BETWEEN CLEANOUTS IS 50'. 2. INSTALL C.O. AS INDICATED 45° BEND PVC T-WYE FLOW UNDISTURBED PVC PIPE EXISTING SANITARY ON PLAN 45° BEND SEWER MAIN P L A N S W H I C H D O N O T B E A R SUBGRADE AN EMBOSSED SEAL ARE NOT VALID. SDR 35 PVC WYE
SDR 35 PVC WYE (DIAMETER VARIES) END CAP PVC WYE OR TEE SADDLE TURNED 45° ALL DOCUMENTS PREPARED BY HUDSON ENGINEERING, FLOW LLC ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE SECTION A-A GRAVEL TO DEEP CONNECTION PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
SPRINGLINE OF TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON MINIMUM SLOPE TO SEWER E X T E N S I ON S OF T HE P R O JE C T O R O N A N Y OT HE R SDR 35 PVC ELEVATION WYE/TEE PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION MAIN TO BE 41" PER FT. OR ADAPTATION BY HUDSON ENGINEERING, LLC FOR THE SANITARY SEWER SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO HUDSON ENGINEERING, LLC; AND OWNER SHALL 4 BRICK SEWER CONNECTION 5 SANITARY CLEANOUT DETAIL 6 SERVICE LATERAL DETAIL 7 SANITARY SEWER SERVICE DETAIL INDEMNIFY AND HOLD HARMLESS HUDSON ENGINEERING, LLC FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM C1.12 SCALE: N.T.S. C1.12 SCALE: N.T.S. C1.12 SCALE: N.T.S. C1.12 SCALE: N.T.S. BY CHK ---- ----