JM 14. SEAL PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD NO. FIN. FLOOR PRINCIPAL IN CHARGE WALLS. EXTERIOR ELEVATION REFERENCE EL. 0'-0" ELEVATION / DATUM 15. SEAL PLUMBING PIPE PENETRATIONS THROUGH GWB. SHT. CC RATED WALL MARKING - IBC 703.7 PROJECT TEAM 16. PROVIDE GYPSUM BASED UNDERLAYMENT BENEATH TUBS AND SHOWERS. 17. SEAL TUB AND SHOWER DRAINS TO SUBFLOOR.
EL. 0'-0" JM ELEVATION / DATUM 18. SEAL TUB AND SHOWER ENCLOSURE TO SUBFLOOR AND WALL. NO CHECKED BY 19. SEAL SHOWER HEAD TO TILE OR SHOWER SURROUND. - WHERE THIS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACE, FIRE WALLS, FIRE BARRIERS, SHEET DESCRIPTION 20. PROVIDE SEALANT AT FIRE SPRINKLER HEAD ESCUTCHEONS TO GWB. FIRE PARTITIONS SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE NO NO INTERIOR ELEVATION REFERENCE FLOOR ELEVATION CHANGE
LEGEND SHEET 21. SEAL ATTIC AND CRAWLSPACE ACCESS COVERS TO GWB OR SUBFLOOR. SHT. PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR 22. SEAL RECESSED HEATERS (PTACS) TO GWB. STENCILING IN THE CONCEALED SPACE. 23. INSULATE DUCTWORK LOCATED WITHIN FLOOR/CEILING ASSEMBLIES. - TEXT TO BE LOCATED A MAXIMUM OF FIFTEEN FEET FROM THE END OF THE WALL AND AT INTERVALS NOT TO NO 24. SEAL HVAC AND VENTILATION GRILLES, INLETS AND DIFFUSERS TO GWB. EXCEED THIRTY FEET. 25. SEAL KITCHEN AND BATH EXHAUST FAN HOUSING TO GWB. ABCD WALL TYPE INDICATOR ISSUED FOR:
No. Date Description 26. SEAL CLOTHES WASHER VALVE/DRAIN BOX TO GWB. EZ# # (SEE PARITION TYPE SHEET) FLOOR/CEILING ASSEMBLY NO. NO. BUILDING SECTION REFERENCE 27. SEAL CLOTHES DRYER EXHAUST BOX SEALED TO GWB. 28. SEAL BUILT-IN CABINETS TO GWB. SHT. SHT. 29. FASTEN CEILING MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT CEILING. ACCESSIBLE CONCEALED AREA XX OF FLOOR/CEILING ASSEMBLY FLOOR / CEILING OR ROOF / CEILING 30. FASTEN
FLOOR / CEILING OR ROOF / CEILING 30. FASTEN WALL BASE MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT FLOOR XX FIRE AND/OR SMOKE FIRE AND/OR SMOKE TYPE INDICATOR LINE. BARRIER - PROTECT BARRIER - PROTECT 31. PROVIDE VIBRATION ISOLATION OF THE OVERHEAD GARAGE DOOR TRACKS. ALL OPENINGS ALL OPENINGS NO. WALL SECTION REFERENCE 32. PROVIDE VIBRATION ISOLATION OF THE GARAGE DOOR OPENER WITH RESILIENT SHT. MOUNTING HARDWARE. 15' MAX. 30' MAX. 1 KEYNOTE INDICATOR ACOUSTICAL CEILING OR
ACOUSTICAL CEILING OR A0.01A N. SOUND CONTROL MATERIALS - USE A COMBINATION OF THE FOLLOWING: OTHERWISE ACCESSIBLE ROOM NAME CEILING SYSTEM ROOM INDICATOR 1 REVISION INDICATOR 1. NON-HARDENING CAULK - SEALS GAPS LESS THAN 1/2" WIDE. NO. 2. SPRAY FOAM - FILLS LARGE GAPS AND SMALL HOLES. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 4. GASKETS - NEOPRENE, RUBBER, FOAM. UNIT TYPE FIRE WALL, FIRE BARRIER, FIRE UNIT INDICATOR 5.
FIRE WALL, FIRE BARRIER, FIRE UNIT INDICATOR 5. ACOUSTICAL SOUND MAT MEMBRANE. NO. SHEET NUMBER 6. GYPSUM BASED UNDERLAYMENT AT WOOD SUB-FLOORS. PARTITION, SMOKE BARRIER EXAMPLE OF CONCEALED CEILING SPACE 7. SOUND CONTROL MAT BENEATH HARD FLOOR SURFACES. OR SMOKE PARTITION 8. RESILIENT CHANNELS - DIETRICH RC DELUXE RCSD 9. SOUND ISOLATION CLIPS USED WITH METAL FURRING CHANNELS. 3" HIGH, MIN. 10. GYPSUM WALL BOARD. DOB APPROVAL STAMP: FIRE AND/OR SMOKE 11. VIBRATION ISOLATION DEVICES. BARRIER - PROTECT ALL
BARRIER - PROTECT ALL OPENINGS 3/8" STROKE, MIN. EXAMPLE OF REQUIRED TEXT COPYRIGHT © JORGE MASTROPIETRO ATELIER ARCHITECTS
HANDICAPPED ACCESSIBLE MOUNTING HEIGHTS PER ICC/ANSI A117.1-2017 3 4 12 8 11 10 9 7 7 1 6 5 2 5 13 5 5 BOTTOM OF 54" MIN. MIN. 1 1/2" REFLECTIVE 39"-41" SURFACE
39"-41" SURFACE 1123 BROADWAY, SUITE 302, NY, NY 10010 TOP OF RIM 2 1 13 12" MAX. 24" 12" PHONE 646.248.6664 SPOUT HEIGHT WWW.JMAPC.COM