Supporting Documentation · Jun 3, 2026
JMA02P00301 262 270 MAIN STREET
d7c4d01f73b7886c3ee3ab9014a1ed38e8d85378c42ecba1f33c333b9396bb64Indexed text
THERMOPLASTIC IN ACCORDANCE WITH SECTION 610 - TRAFFIC STRIPES JOB No. : AND MARKINGS OF THE NJDOT STANDARD SPECIFICATIONS, AND MEET JMA02P003.01 04 of 15 NEW JERSEY DEPARTMENT OF TRANSPORTATION SPECIFICATIONS
TREE COUNT NOTES: 1. PER S25-12.1o 1.1. IN PARKING AREAS WITH THIRTY (30) OR MORE PARKING SPACES, H THERE SHAL LBE MINIMUM OF ONE (1) TREEE PLUS GROUND LEVEL U HE
HE PLANTING FOR TEN (10) PARKING STALLS 1.2. PARKING STALLS: TOTAL 46 1.3. 1.4. TREE COUNT REQUIRED: 4 TREE COUNT PROVIDED: 6
D EXISTING 24" TREE TO BE PERMITTING NOTES: 1. TREE REMOVAL AND REPLACEMENT PERMIT WILL BE SUBMITTED TO THE S TOWNSHIP FORESTER, PRIOR TO ANY DISTURBANCE. REMOVED LIST OF NATIVE AND ADAPTED SPECIES:
O 1. TREES: 1.1. 1.2. "REDMOND" AMERICAN BASSWOOD (TILIA AMERICANA) RIVER BIRCH (BETULA NIGRA) ENGINEERING
ENGINEERING 2. SHRUBS: 2.1. SUMMERSWEET (CLETHRA ALNIFOLIA) HUDSON ENGINEERING, LLC T3 UP 2.2. WINTERBERRY HOLLY (ILEX VERTICILLATA) 25 WEST 8TH STREET, STE B UP 3. EVERGREEN TREES: 3.1. AMERICAN HOLLY (ILEX OPACA) BAYONNE, NEW JERSEY 07002
4. REFER TO TOWNSHIP OF WEST ORANGE PREFERRED TREE PLANTING LIST (201) 589-0906 FOR OTHER PREFERRED TREE SPECIES. EXISTING TREES TO BE REPLACED TREE PLANTING SCHEDULE MARK SPECIES COUNT INSTALL SIZE T2 T1 AMERICAN HOLLY 2 2.5"-3.5" CALIPER DATE: 05/26/2026 EXISTING T2 REDMOND AMERICAN BASSWOOD 8 2.5"-3.5" CALIPER ELECTRICAL
T2 REDMOND AMERICAN BASSWOOD 8 2.5"-3.5" CALIPER ELECTRICAL EXISTING TREES TO JORDAN CECININI POLE EXISTING 12" REMAIN T3 RIVER BIRCH 7 2.5"-3.5" CALIPER NJ PROFESSIONAL ENGINEER LIC. NO. GE54968 TREE TO BE TOTAL 17 REMOVED PROPOSED SHADE TREE PIT NOTES: EVERGREEN TREES 1. TREE PITS ARE NOT PROPOSED ALONG PROSPECT STREET. THERE IS NO
PITS ARE NOT PROPOSED ALONG PROSPECT STREET. THERE IS NO (TYP) APPLICABLE AREA FOR TREE PITS ALONG THE PROPERTY LINE THAT WILL NOT IMPEDE ACCESS TO THE SITE. PLANNING BOARD CHAIRMAN 2. TREE PITS SHALL BE INSTALLED MINIMUM TWO (2) FEET WIDE BY FOUR (4) FEET EXISTING TREES T1 LONG. REFER TO SHADE TREE DETAILS. TO BE REPLACED DN PLANNING BOARD SECRETARY T2
PLANNING BOARD SECRETARY T2 TREE SPACING REQUIREMENTS 1. DO NOT PLANT DIRECTLY IN FRONT OF BUILDING ENTRANCES IN ORDER TO ERWIN PL. PERMIT EASY ACCESS BY THE FIRE DEPARTMENT AND OTHER EMERGENCY 50.00' R.O.W. T1 SERVICES. A TREE MAY BE PLACED IN FRONT OF AN ENTRANCE IF THE SIDEWALK IS AT LEAST 15’ WIDE AT THAT POINT OR THE DISTANCE FROM THE ENTRANCE TO PLANNING BOARD ENGINEER PROPOSED RAIN
File revisions (1)
- Sep 29, 2026
d7c4d01f73b748,133,724 bytes