Show all pagesAIR SEALING GUIDELINES A. B. C. D. E. F. THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY SEALED TO LIMIT AIR INFILTRATION. THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION. OPENINGS AND PENETRATIONS IN THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULKING MATERIALS OR CLOSED WITH GASKETING SYSTEMS COMPATIBLE WITH THE CONSTRUCTION MATERIALS AND LOCATIONS. JOINTS AND SEAMS SHALL BE SEALED IN THE SAME MANNER OR TAPED OR COVERED WITH A MOISTURE VAPOR-PERMEABLE WRAPPING MATERIAL. SEALING MATERIALS SPANNING JOINTS BETWEEN CONSTRUCTION MATERIALS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF THE CONSTRUCTION MATERIALS. OUTDOOR AIR INTAKES AND EXHAUST OPENINGS INTEGRAL TO THE BUILDING ENVELOPE SHALL BE EQUIPPED WITH NOT LESS THAN A CLASS I MOTORIZED, LEAKAGE-RATED DAMPER WITH A MAXIMUM LEAKAGE RATE OF 4 CFM PER SQUARE FOOT WHEN TESTED IN ACCORDANCE WITH AMCA 500D. GRAVITY DAMPERS ARE PERMITTED TO BE USED IN BUILDINGS LESS THAN THREE STORIES IN HEIGHT ABOVE GRADE. VESTIBULE DOORS (WHEN REQUIRED BY CODE) THAT SEPARATE CONDITIONED SPACE FROM THE EXTERIOR SHALL BE EQUIPPED WITH SELF-CLOSING DEVICES. RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. RECESSED LUMINAIRES SHALL BE IC-RATED AND LABELED AS MEETING ASTM E 283 FOR AIR TIGHTNESS. RECESSED LUMINAIRES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND INTERIOR WALL OR CEILING COVERING. THE FOLLOWING SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED WITH AN AIR BARRIER MATERIAL, SUITABLE FILM OR SOLID MATERIAL. ROCK WOOL AND FIBERGLAS BATT INSULATION ARE NOT ACCEPTABLE AS AN AIR BARRIER MATERIAL. AIR SEAL THE FOLLOWING LOCATIONS BEFORE INSULATION: 1. MUD SILL TO FOUNDATION. 2. RIM JOIST TO MUD SILL. 3. TOP PLATE TO RIM JOIST BETWEEN CONDITIONED STORIES. 4. SUBFLOOR SHEATHING TO RIM JOIST BETWEEN CONDITIONED STORIES. 5. SUBFLOOR SHEATHING T&G AND SQUARE EDGE JOINTS. 6. PARTITION WALL STUDS AT EXTERIOR WALL INTERSECTIONS. 7. TOP PLATES OF EXTERIOR STUD WALLS BETWEEN CONDITIONED STORIES. 8. DROPPED CEILINGS, SOFFITS AND CHASES. 9. ATTIC KNEEWALLS AND JOIST CAVITIES UNDER ATTIC KNEEWALLS. 10.TUB/SHOWER ENCLOSURE TO SUBFLOOR. 11.MASONRY FIREPLACE TO SUBFLOOR. 12.ELECTRICAL SERVICE PANEL ON EXTERIOR WALL OR TENANT SEPARATION WALLS. 13.HVAC DUCT JOINTS
OIST CAVITIES UNDER ATTIC KNEEWALLS. 10.TUB/SHOWER ENCLOSURE TO SUBFLOOR. 11.MASONRY FIREPLACE TO SUBFLOOR. 12.ELECTRICAL SERVICE PANEL ON EXTERIOR WALL OR TENANT SEPARATION WALLS. 13.HVAC DUCT JOINTS AND SEAMS SEALED WITH MASTIC. 14.REGISTER BOOTS SEALED TO SUBFLOOR. 15.EXHAUST VENTILATION DUCT JOINTS AND SEAMS SEALED WITH MASTIC. 16.WIRING PENETRATIONS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. 17.WIRING INTO ELECTRICAL BOXES. 18.PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. 19.BATH AND SHOWER DRAINS TO SUBFLOOR. AIR SEAL THE FOLLOWING LOCATIONS AFTER GYPSUM WALL BOARD INSTALLATION: 1. PROVIDE 1/4" SEALANT AT GWB TO SUBFLOOR AT EXTERIOR WALLS AND TENANT SEPARATION WALLS. 2. DOOR FRAMES TO GWB AT EXTERIOR WALLS AND CORRIDOR WALLS. 3. WINDOW FRAMES TO GWB AT EXTERIOR WALLS. 4. TUB/SHOWER ENCLOSURE TO GWB. 5. ATTIC AND CRAWLSPACE ACCESS COVERS TO GWB OR SUBFLOOR. 6. ATTIC ACCESS PULL-DOWN STAIRS SEALED WITH WEATHERSTRIPPING ON COVER. 7. RECESSED LIGHT HOUSING TO GWB. 8. RECESSED WALL HEATERS (PTACS) SEALED TO GWB. 9. HVAC GRILLE AND DIFFUSER TO GWB. 10.VENTILATION GRILLES AND INLETS TO GWB. 11.PLUMBING PIPE PENETRATIONS THROUGH GWB. 12.SHOWER HEAD TO TILE OR SHOWER SURROUND. 13.CLOTHES WASHER VALVE/DRAIN BOX TO GWB. 14.CLOTHES DRYER EXHAUST BOX SEALED TO GWB. 15.BUILT-IN CABINETS TO GWB. 16.STAIRWAYS IN CONTACT WITH EXTERIOR WALL SHALL BE SEALED AT GWB. 17.FIREPLACE BOX TO GWB. 18.COMBUSTION AIR SUPPLY DUCTS AND PIPES TO GWB. 19.METAL FLUES TO GWB. 20.KITCHEN AND BATH EXHAUST FAN HOUSING TO GWB. 21.ELECTRICAL BOXES TO GWB. 22.CABLE/PHONE BOXES TO GWB. AIR SEALING MATERIALS - USE A COMBINATION OF THE FOLLOWING: 1. CAULK - SEALS GAPS LESS THAN 1/2" WIDE. 2. SPRAY FOAM - FILLS LARGE GAPS AND SMALL HOLES. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 4. GASKETS. 5. BUILDING WRAP - INSTALLED OVER EXTERIOR SHEATHING, SEALED WITH TAPE AT LAP JOINTS. 6. SHEET GOODS - WOOD SHEATHING, GYPSUM WALL BOARD AND RIGID FOAM INSULATION WITH EDGES TAPED OR CAULKED. 7. SHEET METAL - EDGES CAULKED. 8. POLYETHYLENE PLASTIC - EDGES AND PENETRATIONS TAPED AND SEALED. 9. WEATHERSTRIPPING - USED TO SEAL MOVEABLE COMPONENTS SUCH AS DOORS, WINDOWS AND ATTIC ACCESS. 10.MASTIC - SEALS AIR HANDLERS AND AIR DISTRIBUTION DUCT CONNECTIONS AND JOINTS. 11.UL181 OR FOIL FACED TAPE - PROVIDES TEMPORARY SEAL ON AIR HANDLER AND DUCTS- NOT
AS DOORS, WINDOWS AND ATTIC ACCESS. 10.MASTIC - SEALS AIR HANDLERS AND AIR DISTRIBUTION DUCT CONNECTIONS AND JOINTS. 11.UL181 OR FOIL FACED TAPE - PROVIDES TEMPORARY SEAL ON AIR HANDLER AND DUCTS- NOT ACCEPTABLE. SOUND CONTROL GUIDELINES A. B. C. D. E. F. G. H. I. J. K. OPENINGS AND PENETRATIONS IN CONSTRUCTION ASSEMBLIES FOR PIPING, ELECTRICAL DEVICES, RECESSED CABINETS, BATHTUBS, SOFFITS, OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BE SEALED, LINED INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED STC RATING OF THE ASSEMBLY. FLOOR ASSEMBLIES THAT ARE CARPETED GENERALLY MEET THE MINIMUM IIC REQUIREMENTS. FLOOR ASSEMBLIES WITH HARD SURFACE FINISHES SUCH AS TILE, WOOD OR VINYL GENERALLY REQUIRE ADDITIONAL ACOUSTICAL TREATMENT OR INSULATION TO MEET THE MINIMUM IIC REQUIREMENTS. THE FIRST ESSENTIAL FOR AIRBORNE SOUND ISOLATION USING ANY SYSTEM IS TO CLOSE OFF AIR LEAKS AND/OR FLANKING PATHS BY WHICH NOISE CAN GO THROUGH OR AROUND THE SYSTEM. SMALL CRACKS OR HOLES WILL INCREASE THE SOUND TRANSMISSION AT THE HIGHER FREQUENCIES. THIS CAN HAVE A DETRIMENTAL EFFECT ON THE OVERALL ACOUSTIC PERFORMANCE AND THE STC VALUE, PARTICULARLY FOR HIGHER ACOUSTICALLY RATED SYSTEMS. FAILURE TO OBSERVE SPECIAL CONSTRUCTION PRECAUTIONS CAN REDUCE THE EFFECTIVENESS OF THE PLANNED SOUND CONTROL METHODS. SYSTEMS SHALL BE AIRTIGHT. RECESSED WALL FIXTURES SUCH AS MEDICINE CABINETS, OR ELECTRICAL, TELEPHONE, AND TELEVISION DEVICES, WIRING, SPRINKLER PIPES, ETC., WHICH PENETRATE THE GYPSUM BOARD, SHALL NOT BE LOCATED BACK-TO-BACK OR IN THE SAME STUD CAVITY. ANY OPENING FOR SUCH FIXTURES AND FOR PIPING OUTLETS SHALL BE CUT TO THE PROPER SIZE AND SEALED. ELECTRICAL DEVICES SHALL BE INSTALLED IN FULL BOXES AND SEALED WITH A NON-HARDENING SEALANT, SUCH AS 3M BRAND FIRE BARRIER, MPP-4S MOLDABLE PUTTY PAD OR EQUAL. THE ENTIRE PERIMETER OF AN ACOUSTICAL ASSEMBLY SHALL BE MADE AIRTIGHT TO PREVENT SOUND TRANSMISSION THROUGH THE ASSEMBLY AND PREVENT SOUND FLANKING AROUND THE ASSEMBLY AND THROUGH ASSEMBLY PENETRATIONS. FLEXIBLE SEALANT OR AN ACOUSTICAL GASKET SHALL BE USED TO SEAL BETWEEN THE STC RATED ASSEMBLY AND ALL DISSIMILAR SURFACES AND ALSO BETWEEN THE ASSEMBLY AND SIMILAR SURFACES WHERE PERIMETER RELIEF IS REQUIRED. THE SPACING AND NUMBER OF MECHANICAL FASTENERS IS ALSO OF GREAT IMPORTANCE IN ACHIEVING A LISTED STC OR IIC RATING. PERIMETER SEALS IN WALL ASSEMBLIES: IN ORDER TO BE
ERE PERIMETER RELIEF IS REQUIRED. THE SPACING AND NUMBER OF MECHANICAL FASTENERS IS ALSO OF GREAT IMPORTANCE IN ACHIEVING A LISTED STC OR IIC RATING. PERIMETER SEALS IN WALL ASSEMBLIES: IN ORDER TO BE EFFECTIVE FOR THE LIFE OF THE BUILDING, SEALANTS MUST BE RESILIENT AND NON-HARDENING. STANDARD WEATHER CAULKING IS UNSATISFACTORY AS AN ACOUSTICAL SEALANT, SINCE IT TENDS TO HARDEN OVER TIME. PLACEMENT OF THE SEALANT IS CRITICAL. THE PURPOSE OF THE SEAL IS TO PROVIDE A RESILIENT CLOSURE BETWEEN ONE SIDE OF AN ASSEMBLY AND THE OTHER, WHICH REDUCES THE POTENTIAL FOR FLANKING NOISE TRANSMISSION. THE PREFERRED PROCEDURE IS TO INSTALL THE GYPSUM WALL BOARD WITH A MINIMUM 1/4" GAP BETWEEN THE ADJACENT CEILING GYPSUM PANEL AND ALSO AT THE SUBFLOOR. SEALANT SHOULD BE APPLIED TO FILL THE PERIMETER GAP BETWEEN THE GYPSUM WALL BOARD AND THE SURROUNDING FLOOR, WALL AND CEILING COMPONENTS. CAULKING SHOULD NOT BE PLACED BENEATH THE SILL PLATE OR RUNNER TRACK OF A WALL ASSEMBLY. INSULATION INDICATED TO BE PROVIDED IN A WALL ASSEMBLY SHALL BE THE SAME DEPTH AS THE WALL STUD FRAMING. UNLESS OTHERWISE REQUIRED BY CODE, REGULAR UN- FACED GLASS FIBER OR MINERAL WOOL INSULATION IS ACCEPTABLE. DO NOT OVERSTUFF THE INSULATION, AS THIS WILL REDUCE THE ACOUSTICAL PERFORMANCE OF THE ASSEMBLY. RESILIENT METAL COMPONENTS - RESILIENT CHANNELS SHALL BE DIETRICH RC DELUXE RCSD. RESILIENT CHANNELS POSSESS A SPRING ACTION TO DECOUPLE AND ISOLATE THE COMPONENTS THEY CONNECT, WHILE PROVIDING THE STRENGTH TO FIRMLY SUPPORT THESE COMPONENTS. A CONCERN IN THE INSTALLATION OF GYPSUM BOARD ON RESILIENT CHANNELS IS THE LENGTH OF THE FASTENER AND THE PLACEMENT OF THE FASTENER. THE FASTENER SHOULD NOT EXTEND INTO THE STUD OR JOIST, THUS SHORTING OUT THE RESILIENCY OF THE SYSTEM. AN EFFECTIVE INSTALLATION TECHNIQUE IS TO PLACE SCREWS ONLY BETWEEN STUDS OR JOISTS. THE CHANNEL MUST ALSO BE FREE TO FLOAT UPON INSTALLATION AND THUS A MINIMUM 1/4" INCH CLEARANCE BETWEEN IT AND THE ADJACENT ASSEMBLY IS REQUIRED. THE RESILIENT CHANNEL SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. PIPES AND ELECTRICAL CONDUITS SHALL BE CONCENTRICALLY PLACED WITHIN WALL AND FLOOR/CEILING ASSEMBLIES, UNLESS OTHERWISE REQUIRED PER FIRE AND OTHER BUILDING CODES. REFER TO OTHER DRAWINGS, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION PERTAINING TO WALL AND FLOOR/CEILING ASSEMBLIES. THE FOLLOWING ITEMS
THERWISE REQUIRED PER FIRE AND OTHER BUILDING CODES. REFER TO OTHER DRAWINGS, DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION PERTAINING TO WALL AND FLOOR/CEILING ASSEMBLIES. THE FOLLOWING ITEMS SHALL BE CAULKED, GASKETED, OR OTHERWISE ACOUSTICALLY TREATED, WHERE OCCURRING AT DWELLING UNIT SEPARATION WALLS, CORRIDOR WALLS, AND FLOOR/CEILING ASSEMBLIES. 1. STAGGER AND OVERLAP JOINTS IN MULTI-LAYER GWB WALLS AND CEILINGS. 2. PROVIDE 1/4" SEALANT JOINT AT GWB TO SUBFLOOR AND CEILING AT DWELLING UNIT SEPARATION WALLS. 3. PROVIDE 1/4" SEALANT JOINT AT GWB TO SUBFLOOR AND CEILING AT CORRIDOR WALLS. 4. PROVIDE 1/4" SEALANT JOINT AT DOOR FRAMES TO GWB AT CORRIDOR WALLS. 5. PROVIDE FLEXIBLE GASKET (SMOKE SEAL) AT DOORS IN CORRIDOR WALLS. 6. PROVIDE SEAL AT BOTTOM OF DOORS IN CORRIDOR WALLS. 7. ELECTRICAL SERVICE PANEL SHOULD NOT BE LOCATED ON DWELLING UNIT SEPARATION OR CORRIDOR WALLS. 8. SEAL EXHAUST VENTILATION DUCT JOINTS AND SEAMS WITH MASTIC. 9. SEAL WIRING PENETRATIONS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. 10. SEAL ELECTRICAL/CABLE/PHONE BOXES TO GWB WITH PUTTY PADS OR APPROVED EQUAL. 11. SEAL WIRING INTO ELECTRICAL BOXES. 12. SEAL RECESSED LIGHT HOUSING TO GWB. 13. PROVIDE FIRE RESISTANCE RATED COVER AROUND RECESSED LIGHTING HOUSING. 14. SEAL PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. 15. SEAL PLUMBING PIPE PENETRATIONS THROUGH GWB. 16. PROVIDE GYPSUM BASED UNDERLAYMENT BENEATH TUBS AND SHOWERS. 17. SEAL TUB AND SHOWER DRAINS TO SUBFLOOR. 18. SEAL TUB AND SHOWER ENCLOSURE TO SUBFLOOR AND WALL. 19. SEAL SHOWER HEAD TO TILE OR SHOWER SURROUND. 20. PROVIDE SEALANT AT FIRE SPRINKLER HEAD ESCUTCHEONS TO GWB. 21. SEAL ATTIC AND CRAWLSPACE ACCESS COVERS TO GWB OR SUBFLOOR. 22. SEAL RECESSED HEATERS (PTACS) TO GWB. 23. INSULATE DUCTWORK LOCATED WITHIN FLOOR/CEILING ASSEMBLIES. 24. SEAL HVAC AND VENTILATION GRILLES, INLETS AND DIFFUSERS TO GWB. 25. SEAL KITCHEN AND BATH EXHAUST FAN HOUSING TO GWB. 26. SEAL CLOTHES WASHER VALVE/DRAIN BOX TO GWB. 27. SEAL CLOTHES DRYER EXHAUST BOX SEALED TO GWB. 28. SEAL BUILT-IN CABINETS TO GWB. 29. FASTEN CEILING MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT CEILING. 30. FASTEN WALL BASE MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT FLOOR LINE. 31. PROVIDE VIBRATION ISOLATION OF THE OVERHEAD GARAGE DOOR TRACKS. 32. PROVIDE VIBRATION ISOLATION OF THE GARAGE DOOR OPENER WITH RESILIENT MOUNTING
TO WALL ONLY. PROVIDE SEALANT JOINT AT FLOOR LINE. 31. PROVIDE VIBRATION ISOLATION OF THE OVERHEAD GARAGE DOOR TRACKS. 32. PROVIDE VIBRATION ISOLATION OF THE GARAGE DOOR OPENER WITH RESILIENT MOUNTING HARDWARE. N. SOUND CONTROL MATERIALS - USE A COMBINATION OF THE FOLLOWING: 1. NON-HARDENING CAULK - SEALS GAPS LESS THAN 1/2" WIDE. 2. SPRAY FOAM - FILLS LARGE GAPS AND SMALL HOLES. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 4. GASKETS - NEOPRENE, RUBBER, FOAM. 5. ACOUSTICAL SOUND MAT MEMBRANE. 6. GYPSUM BASED UNDERLAYMENT AT WOOD SUB-FLOORS. 7. SOUND CONTROL MAT BENEATH HARD FLOOR SURFACES. 8. RESILIENT CHANNELS - DIETRICH RC DELUXE RCSD 9. SOUND ISOLATION CLIPS USED WITH METAL FURRING CHANNELS. 10. GYPSUM WALL BOARD. 11. VIBRATION ISOLATION DEVICES. NO. SHT. DETAIL SECTION REFERENCE NO. SHT. DETAIL / ENLARGED PLAN REFERENCE NO. SHT. EXTERIOR ELEVATION REFERENCE NO. SHT. WALL SECTION REFERENCE ROOM NAME NO. NO. NO. FIN. FLOOR EL. 0'-0" ABCDE Z# # ROOM INDICATOR BUILDING DOOR INDICATOR WINDOW / STOREFRONT TYPE INDICATOR ELEVATION / DATUM WALL TYPE INDICATOR (SEE PARITION TYPE SHEET) REVISION INDICATOR INTERIOR ELEVATION REFERENCE 1 REFERENCE SYMBOLS SHT. NO NO NONO NO. SHT. BUILDING SECTION REFERENCENO. SHT. UNIT TYPE NO. UNIT INDICATOR XX XX UNIT DOOR INDICATOR XX XX FLOOR / CEILING OR ROOF / CEILING TYPE INDICATOR KEYNOTE INDICATOR1 EL. 0'-0" ELEVATION / DATUM FLOOR ELEVATION CHANGE RATED WALL MARKING - IBC 703.7 - WHERE THIS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACE, FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN THE CONCEALED SPACE. - TEXT TO BE LOCATED A MAXIMUM OF FIFTEEN FEET FROM THE END OF THE WALL AND AT INTERVALS NOT TO EXCEED THIRTY FEET. FLOOR/CEILING ASSEMBLY ACCESSIBLE CONCEALED AREA OF FLOOR/CEILING ASSEMBLY FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE BARRIER OR SMOKE PARTITION FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS ACOUSTICAL CEILING OR OTHERWISE ACCESSIBLE CEILING SYSTEM 15' MAX. FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS 30' MAX. EXAMPLE OF CONCEALED CEILING SPACE EXAMPLE OF REQUIRED TEXT FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS 3/8" STROKE, MIN. 3" HIGH, MIN. GROUND FAULT INTERRUPTER STANDARD
ECT ALL OPENINGS 30' MAX. EXAMPLE OF CONCEALED CEILING SPACE EXAMPLE OF REQUIRED TEXT FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS 3/8" STROKE, MIN. 3" HIGH, MIN. GROUND FAULT INTERRUPTER STANDARD ARCHITECTURAL ABBREVIATIONS PTD PAINTED HWH HOT WATER HEATER VOLT WEST WITH V UTIL VCT VERT VEST VAV VB RECEIVED RECESSED REFERENCE VAC VOL VR VWC VT VNR REQUIRED RESILIENT ROOFING W/W W/R W W/O WC REVERSE ROOF VENT ROUND W/ VIB LEVEL LOUVER METER MAINTENANCE MARBLE MASONRY RECPT REF RECT RCP REC RECD RD RC MEMBER MECHANICAL MAXIMUM METAL MANUFACTURER MANUFACTURING MEMBRANE MEZZANINE MEDIUM REQD RHR RV RO RVS RND RFM RESIL RH RFG REM MATERIAL REINF ROOF DRAIN REINFORCED CONCRETE REINFORCED CONCRETE PIPE REMOVABLE RECEPTACLE REINFORCEMENT RECTANGULAR RIGHT HAND RIGHT HAND REVERSE RECESSED FLOOR MAT ROUGH OPENING LVR LVL MAINT MARB MAS M LWC LW PLAS FLUORESCENT FLOAT GLASS FIREPLACE FIREPROOFING FACE OF STUD FACE OF MASONRY FACE OF CONCRETE FLOOR FINISH MBR MC MDO MECH MAX MEMB MFR MET MEZZ MFG MED FINISHED SURFACE FURRING FOOTING FASTENER GRAB BAR FIXTURE FIRE STANDPIPE GALVANIZED GENERAL CONTRACTOR FUTURE FRONT FRAME MATL CORNER FLT GL FLR FIN COLUMN FOS FPRF FPL FOC FOM FLUOR CONCRETE FLOOR COMPLETE CONCRETE CLEANOUT COUNTER FS FSP FTG FSTNR FRNT CASING FUT GALV FXTR GB GC FURR CONSTRUCTION COLD ROLLED STEEL CIRCUMFERENCE COMPRESSIBLE COVER PLATE COUNTERSUNK CONTRACTOR COORDINATE CONTINUOUS CONNECTION CONFERENCE FRM MEDIUM DENSITY OVERLOAD MOMENT CONNECTION LIGHTWEIGHT PLASTER LIGHTWEIGHT CONCRETE WHSE WGL WH WF WDW SALVAGE SCHEDULE SOLID CMU WT WTR WLD WSCT WS SECTION SINGLE SHOWER SHEATHING SCREEN WL VWC WWM X SECT SLEEVE SLOPE SLIP JOINT SIMILAR SINK SPACING SPECIAL SEAMLESS SPRINKLER SPEAKER SHELVES WTRPRF MARK MISCELLANEOUS MOLDING MIRROR METAL LATH MEETING MORTAR MODULE MARBLE THRESHOLD MILLWORK SHR SHTHG SCMU SD SCRN SGL SECT SALV SC SCHED SB NORTH NOT APPLICABLE NEAR FACE NEGATIVE MOVABLE MULTIPLE NOT IN CONTRACT NOMINAL OUT TO OUT NEAR SIDE NUMBER NOT TO SCALE SP SPCL SPKR SPEC SPKLR SK SLV SM SMLS SLP SJ SIM MULLION SHVL SOLID CORE STORM DRAIN SPLASH BLOCK SPECIFICATION SHEET METAL SQUARE SUPPORT STREET STIRRUP STANDARD STORAGE STEEL SURFACE SYMBOL SUSPENDED OVERALL ON CENTER OUTSIDE FACE OWNER INSTALLED OPENING OPPOSITE OPTIONAL OFFICE STD STL JST STIR ST SS SSK STAG SQ FT SPRT SQ IN SQ
PPORT STREET STIRRUP STANDARD STORAGE STEEL SURFACE SYMBOL SUSPENDED OVERALL ON CENTER OUTSIDE FACE OWNER INSTALLED OPENING OPPOSITE OPTIONAL OFFICE STD STL JST STIR ST SS SSK STAG SQ FT SPRT SQ IN SQ YD SQ PAINT OVERHEAD OXYGEN PARALLEL ORIGINAL PARTICLEBOARD PANIC BAR PEDESTAL PARGING STOR STRUCT STL SUSP CLG SUSP T&B SYMM SYM SURF SUPPL STRUCT STL STL PL SERVICE SINK STAGGERED STAINLESS STEEL STEEL JOIST STEEL PLATE STRUCTURAL STEEL SUPPLEMENT SUSPENDED CEILING TOP AND BOTTOM SYMMETRICAL STRUCTURAL SQUARE FOOT SQUARE INCH SQUARE YARD MLDG MIR MISC MK ML MTG MTR MO MOD MT MLWK GRADING GRATING GENERAL GLAZING GLASS BLOCK GLUE LAMINATED GLAZED CMU GLASS GROUND GRADE BEAM N NA NF NEG MVBL MULT NOM NS O/O NTS NO NIC HEADER HEAVY DUTY HARDBOARD HEAD JOINT HARDWOOD HIGH HOLLOW CMU HOLLOW CORE GYPSUM WALL BOARD GYPSUM PLASTER HOT AND COLD WATER HOSE BIBB GYPSUM MULL CURRENT CUBICLE GLU LAM GFI GENL GL GL BLK DETAIL GR GRTG GLZ CMU GND GR BM GLZ DRINKING FOUNTAIN DOOR FRAME CERAMIC TILE CABLE TELEVISION DOUBLE GLAZING DEPARTMENT COLD WATER CASEWORK DIVIDER GYP PLAS H H&CW HC HB GWB DITTO DOWN DRAIN HD JT HDR HDBD HDWD HD HCMU DOOR CLOSER DOWNSPOUT DOUBLE JOIST DEIONIZED WATER DAMPPROOFING DEAD LOAD DIMENSION DISTANCE DOUBLE HUNG GYP OA OF OD OFCI OC OPNG OPT OPP OFOI OFF HEATING, VENTILATION, HEIGHT HOUR HEATING HIGH STRENGTH HIGH STRENGTH BOLT HORIZONTAL HOLLOW METAL HOLLOW METAL DOOR HOLLOW METAL FRAME HOLD-OPEN HAND RAIL OVHD P PAR OXY ORD ORIG PB PC PCP PED PBD PARG HYDRANT INVERT INLET INSIDE FACE INCANDESCENT INSTALLATION INVERT ELEVATION INTERIOR INSULATION JANITOR AIR CONDITIONING HOT WATER DOWEL HORIZ HM HO HNDRL HMF HMD EAST DRAWER HT HVAC HTG HSB HS HR EXPANSION JOINT EACH FACE ELEVATION DUMBWAITER DISHWASHER DOVETAIL DRAIN TILE DUPLICATE DOOR STOP ENAMEL HYD IF INCAND INL HW EQUAL INSUL INT INV EL JAN INV INSTL EMERGENCY SHOWER EQUALLY SPACED ELECTRICAL PANEL ELECTRICAL OUTLET EXPANDED POLYSTYRENE ENTRANCE ENGINEER ENCLOSURE EMERGENCY ELECTRICAL PORTLAND CEMENT OVERFLOW ROOF DRAIN PORTLAND CEMENT OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OUTSIDE DIAMETER MASONRY OPENING SOUTH CASEMENT GDRL GUARD RAIL MH S MANHOLE WD VOLUME WEIGHT WELDED WIRE MESH WATERPROOFING VINYL WALL COVERING WATER CROSS SECTION WOOD WEATHERSTRIPPING WAREHOUSE WIND LOAD WAINSCOT WELDED WIRE GLASS WALL HUNG WIDE FLANGE WINDOW WATER RESISTANT VINYL WALL COVERING VAPOR
E MESH WATERPROOFING VINYL WALL COVERING WATER CROSS SECTION WOOD WEATHERSTRIPPING WAREHOUSE WIND LOAD WAINSCOT WELDED WIRE GLASS WALL HUNG WIDE FLANGE WINDOW WATER RESISTANT VINYL WALL COVERING VAPOR RETARDER WALL TO WALL WITHOUT WATER CLOSET VINYL TILE VARIABLE AIR VOLUME VINYL COMPOSITION TILE VERTICAL VIBRATION VESTIBULE VENEER VACUUM VINYL BASE UTILITY TECHNICAL THICK THRESHOLD TERRAZZO THROUGH TUNNEL TOTAL TELEVISION TEMPERED PHASE PERFORATED PERPENDICULAR PEGBOARD PERMANENT PERIMETER PLATE PLUMBING PLYWOOD PLASTER PLATFORM T&G TK BD TMPD GL TEMP TER THRU THRES THK TD TC TECH TB-xx PAIR POSITIVE PRECAST POLYSTYRENE PARKING PROJECT PARTITION PRELIMINARY PREFABRICATED TOW TS TV TRNBKL TOFF TOT TOL TOJ TOS TOF TNL POLISHED TMPD TURNBUCKLE TENSILE STRENGTH TOP OF WALL TONGUE AND GROOVE TEMPORARY TACKBOARD TEMPERED GLASS TRENCH DRAIN TOP OF CURB TOP OF FINISH FLOOR TOP OF SLAB TOLERANCE TOP OF JOIST TOP OF FLANGE TEST BORING-xx(E.G. TB-1) UNFINISHED ULTIMATE POWER PAVEMENT QUANTITY QUALITY QUARRY TILE RISER UNO UFD ULT UNEX UNFIN UGND UNDERGROUND UNLESS NOTED OTHERWISE UNEXCAVATED UNDER FLOOR DUCT TYPICAL PAVING TYP PERF PH PERP PGBD PERM PERIM PLBG PLYWD PL PLAS PLAT PLAM JANITOR'S CLOSET LAVATORY POUND LEFT LABORATORY JOIST JOINT KEYWAY KNEE BRACE KNOCKOUT PANEL KNOCKOUT KICK PLATE POS PR PRCST POLY POLYISO PTN PROJ PRKG PVC PRELIM PREFAB LINEAR LOCKER LOCKER ROOM LIQUID LANDING LOAD BEARING LIGHTWEIGHT CMU LENGTH LINEAR FOOT LEFT HAND REVERSE LEFT HAND LUMBER POL JC KOP JT KB JST KO LAV LB LAB L KPL KWY EQUIPMENT EXHAUST HOOD EXHAUST FAN ELECTRIC WATER COOLER ESTIMATE EXISTING EXCAVATE EACH WAY ERECTION EQUIVALENT EASEMENT ESCALATOR LDG LF LG LD BRG LCMU LIN LKR LKR RM LIQ LHR LH FIRE EXTINGUISHER CABINET FOUNDATION FLOOR DRAIN FIBERBOARD FACE TO FACE EXISTING GRADE EXTENSION EXTERIOR FIRE BRICK EXPANSION EXPOSED EXPOSED LBR QT PVMT PWR QUAL QTY R LIGHT LIGHTWEIGHT LINTEL LARGE LONGITUDINAL LUMP SUM LOCATION FLANGE FINISH LOC LONG LNTL LS LRG LT WT FLOOR LT FLOOR PLATE FLOOR SINK FINISH GRADE FLASHING FINISH FLOOR FIBERGLASS LL LIVE LOAD PVG POLYVINYL CHLORIDE PLASTIC LAMINATE POLYISOCYANURATE CNR ANCHOR BOLT COL CO ACCESSIBLE ACOUSTICAL ABOVE CNTR AB A/E ACID RES ACOUS ACC AC ACOUS INSUL ABV ACID-RESISTANT AIR CONDITIONING ACOUSTIC INSULATION ARCHITECT/ENGINEER ADDITIONAL AREA DRAIN ACOUSTIC
R ANCHOR BOLT COL CO ACCESSIBLE ACOUSTICAL ABOVE CNTR AB A/E ACID RES ACOUS ACC AC ACOUS INSUL ABV ACID-RESISTANT AIR CONDITIONING ACOUSTIC INSULATION ARCHITECT/ENGINEER ADDITIONAL AREA DRAIN ACOUSTIC TILE CSG CRS CSK ADJACENT ADJUSTABLE ADDENDUM ACPNL ADC AD ADDL ACOUS TILE ADJ AFF AF ADJC AFG ADDM ACOUSTIC PANEL ABOVE FINISHED FLOOR ACCESS FLOOR AUTOMATIC DOOR CLOSER ABOVE FINISHED GRADE ACOUSTIC PLASTERACOUS PLAS CUR CT CTV CUB ALARM ALUMINUM ALTERNATE AGGREGATE DF DFR DET DEPT ANODIZED ANTENNA AMOUNT AMPLIFIER ANNUNCIATOR AMBIENT CW ALT AHU ALM AL AGGR ANOD ANT AMT AMPL ANN AMB AIR HANDLING UNIT DIV DL DJ DIW DIM DIST APPENDIX ASPHALT AUDIO VISUAL DO DS DR DN AVENUE BALANCE BAFFLE ASC ASPH ASYM AV APPX ARCH BAL BAF BC BB B&B AVE ARCHITECT (URAL) ABOVE SUSPENDED CEILING ASYMMETRICAL BACK OF CURB BULLETIN BOARD BALLED AND BURLAPPED ACCESS PANELAP DH DWL DW DUPL DT DST BITUMINOUS BOARD BEVEL BOTH FACES EF EJ EL E DWR BED JOINT BUILDING BLOCK BULKHEAD BLOCKING BASE LINE BITUM BD BFF BF BFP BEV BLK BLKG BLKHD BJT BLDG BL BELOW FINISH FLOOR BACKFLOW PREVENTER ENCL ELEC BALLAST BEAM BRIDGING BRACING BASE PLATE EO EP EPS EQ ENTR BRICK BRONZE BRASS BRACKET BEARING BP BRCG BRDG BLST BM BRDG JST BRG PL BRK BRZ BRS BRKT BRG BRIDGING JOIST BEARING PLATE ABOVE FINISHED SLABAFS EST ESMT BOTH SIDES BOTTOM BUILT-UP ROOF BASEMENT BOTH WAYS EWC EXG EXC EW CABINET CAVITY CATCH BASIN BS C/C BSMT BTM BW BUR CB CCTV CAB C&G CAV CENTER TO CENTER CLOSED CIRCUIT TV CURB AND GUTTER EXT EXTN EXPN EXSP CHALKBOARD CERAMIC CHANNEL FDN FD FEC FBD F/F CAST IRON CIRCLE CHECK CHAMFER CFLG CH BD CHAN CER CEM PLAS CI CIR CIP CJ CHK CHFR CONTROL JOINT CAST IN PLACE CEMENT PLASTER COUNTER FLASHING CEMENTCEM EXP FIN FL FLG CEILING CLOSET COMPOSITE CLOSURE CLEAR FLR CLG HT CLG DIFF CLL CLG CLOS CMPST CLSR CLR CONTRACT LIMIT LINE CEILING DIFFUSER CEILING HEIGHT CENTER LINECL FGL FLR PL FLR SK FIN GR FIN FL EQUIP EXH HD EXST GR F BRK EXH FN ERECT ESCAL EQUIV EMER SHR EQ SP ENGR ENAM EMER DWTR CONSTR DVTL DRCLSR DMPF CSMT DBL GLZ CSWK CPRS CRCMF CONTR CONT COV PL COORD COMPL CONC FL CONN CONF CONC CMUCONCRETE MASONRY UNIT CPT CARPET LTG LIGHTING RBR RAD RUBBER RADIUS UNINTERRUPTED. POWER SUPPLY UR UPS URINAL UL UNDERWRITERS LABORATORY PRINCIPAL IN CHARGE PROJECT TEAM CHECKED BY SHEET DESCRIPTION ISSUED FOR: SHEET NUMBER COPYRIGHT © JORGE MASTROPIETRO ATELIER ARCHITECTS JORGE E. MASTROPIETRO NY