1.1. MINIMUM LEVELS OF ILLUMINATION OF A B-1 ZONE PER 25-14.3 1.1.1. PEDESTRIAN WALKWAYS: 0.9 FOOTCANDLES 1.1.2. PARKING AREAS: 2.0 FOOT CANDLES 1.1.3. STREETS: 1.2 2. THE PROPOSED LIGHT FIXTURE FOR LOADING RAMP SHALL BE THE S3L ESSEX

Page 11

C-WP-C-RDC SERIES C-LITE CUTOFF LED WALL PACK (OR APPROVED EQUAL), INSTALLED AT 8-6" ABOVE GRADE. 2.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION WITHIN THE RAMP AREA IS 0.9. 3. THE PROPOSED LIGHT FIXTURE FOR PARKING AREAS SHALL BE GLEON-AF-04-LED-E1 ROADWAY LUMINARE, INSTALLED 18' ABOVE GRADE. 3.1. THE MINIMUM

Page 11

3.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION IS 0.5. WEST ORANGE 0' 5' 10' 20' 30' 40' 50' 60' DRAWN BY : DESIGN BY : CHECKED BY : SCALE : HP HP JC AS NOTED

Page 11

SHEET #: 2 LIGHTING PRODUCT SPECIFICATION-PARKING AREA 3 LIGHTING PRODUCT SPECIFICATION-RAMP SCALE: 1/16" = 1'-0" DATE : 05/15/2025 C1.11 BINDING ORDER:

Page 11

BINDING ORDER: JOB No. : C1.11 SCALE: N.T.S C1.11 SCALE: N.T.S JMA02P003.01 11 of 15