Page 11

1.1. MINIMUM LEVELS OF ILLUMINATION OF A B-1 ZONE PER 25-14.3 1.1.1. PEDESTRIAN WALKWAYS: 0.9 FOOTCANDLES 1.1.2. PARKING AREAS: 2.0 FOOT CANDLES 1.1.3. STREETS: 1.2 2. THE PROPOSED LIGHT FIXTURE FOR LOADING RAMP SHALL BE THE S3L ESSEX

Page 11

C-WP-C-RDC SERIES C-LITE CUTOFF LED WALL PACK (OR APPROVED EQUAL), INSTALLED AT 8-6" ABOVE GRADE. 2.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION WITHIN THE RAMP AREA IS 0.9. 3. THE PROPOSED LIGHT FIXTURE FOR PARKING AREAS SHALL BE GLEON-AF-04-LED-E1 ROADWAY LUMINARE, INSTALLED 18' ABOVE GRADE. 3.1. THE MINIMUM

Page 11

3.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION IS 0.5. WEST ORANGE 0' 5' 10' 20' 30' 40' 50' 60' DRAWN BY : DESIGN BY : CHECKED BY : SCALE : HP HP JC AS NOTED

Page 11

SHEET #: 2 LIGHTING PRODUCT SPECIFICATION-PARKING AREA 3 LIGHTING PRODUCT SPECIFICATION-RAMP SCALE: 1/16" = 1'-0" DATE : 05/15/2025 C1.11 BINDING ORDER:

Page 11

BINDING ORDER: JOB No. : C1.11 SCALE: N.T.S C1.11 SCALE: N.T.S JMA02P003.01 11 of 15

Page 12

HUBBED FITTING 4" CONCRETE 6" MIN 45° H COVER CLASS "B" CONCRETE U RISER CLAMP NOTES: 1. WHERE A SEWER LATERAL IS TO CONNECT TO A SEWER CONSTRUCTED OF BRICK OR OTHER SUITABLE MATERIAL, AN CIRCULAR SAWCUT HOLE TO FIT PROPOSED PIPE. GROUT AROUND

Page 12

PROPOSED PIPE. GROUT AROUND OPENING WITH NON-SHRINK, NON-METALLIC GROUT. BOTTOM OF PIPE TRENCH EXISTING SEWER MAIN DIAMETER VARIES. D

Page 12

S HE ASSEMBLY CONSISTING OF A HUBBED FITTING AND RISER CLAMP WILL BE USED. THE RISER CLAMP SHALL BE SET SO SEWER LINER EXISTING SEWER MAIN O

Page 12

SEWER MAIN O A PIPE THAT THE LENGTH OF PIPE INSERTED INTO THE SEWER IS NEW SERVICE EQUAL TO THE THICKNESS OF THE MAIN AS SHOWN IN THE DETAIL. THE ENTIRE CIRCUMFERENCE OF THE ASSEMBLY 90° OR LESS UNDISTURBED CONNECTION 6" MIN

Page 12

CONNECTION 6" MIN SECTION A-A 6" MIN ENGINEERING SHALL BE INFILLED WITH NON-SHRINK, NON-METALLIC GROUT SOIL 45° THICKNESS TO SECURE IN PLACE. HUDSON ENGINEERING, LLC OF SEWER 2. CIRCULAR HOLE SAWS WHICH ARE APPROPRIATELY SIZED OR INFILL WITH HAND DRILLS MUST BE USED TO MAKE THE OPENINGS IN