Supporting Documentation · Jun 3, 2026
JMA02P00301 262 270 MAIN STREET
d7c4d01f73b7886c3ee3ab9014a1ed38e8d85378c42ecba1f33c333b9396bb64Indexed text
1.1. MINIMUM LEVELS OF ILLUMINATION OF A B-1 ZONE PER 25-14.3 1.1.1. PEDESTRIAN WALKWAYS: 0.9 FOOTCANDLES 1.1.2. PARKING AREAS: 2.0 FOOT CANDLES 1.1.3. STREETS: 1.2 2. THE PROPOSED LIGHT FIXTURE FOR LOADING RAMP SHALL BE THE S3L ESSEX
C-WP-C-RDC SERIES C-LITE CUTOFF LED WALL PACK (OR APPROVED EQUAL), INSTALLED AT 8-6" ABOVE GRADE. 2.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION WITHIN THE RAMP AREA IS 0.9. 3. THE PROPOSED LIGHT FIXTURE FOR PARKING AREAS SHALL BE GLEON-AF-04-LED-E1 ROADWAY LUMINARE, INSTALLED 18' ABOVE GRADE. 3.1. THE MINIMUM
3.1. THE MINIMUM FOOT-CANDLES FOR THIS INSTALLATION IS 0.5. WEST ORANGE 0' 5' 10' 20' 30' 40' 50' 60' DRAWN BY : DESIGN BY : CHECKED BY : SCALE : HP HP JC AS NOTED
SHEET #: 2 LIGHTING PRODUCT SPECIFICATION-PARKING AREA 3 LIGHTING PRODUCT SPECIFICATION-RAMP SCALE: 1/16" = 1'-0" DATE : 05/15/2025 C1.11 BINDING ORDER:
BINDING ORDER: JOB No. : C1.11 SCALE: N.T.S C1.11 SCALE: N.T.S JMA02P003.01 11 of 15
HUBBED FITTING 4" CONCRETE 6" MIN 45° H COVER CLASS "B" CONCRETE U RISER CLAMP NOTES: 1. WHERE A SEWER LATERAL IS TO CONNECT TO A SEWER CONSTRUCTED OF BRICK OR OTHER SUITABLE MATERIAL, AN CIRCULAR SAWCUT HOLE TO FIT PROPOSED PIPE. GROUT AROUND
PROPOSED PIPE. GROUT AROUND OPENING WITH NON-SHRINK, NON-METALLIC GROUT. BOTTOM OF PIPE TRENCH EXISTING SEWER MAIN DIAMETER VARIES. D
S HE ASSEMBLY CONSISTING OF A HUBBED FITTING AND RISER CLAMP WILL BE USED. THE RISER CLAMP SHALL BE SET SO SEWER LINER EXISTING SEWER MAIN O
SEWER MAIN O A PIPE THAT THE LENGTH OF PIPE INSERTED INTO THE SEWER IS NEW SERVICE EQUAL TO THE THICKNESS OF THE MAIN AS SHOWN IN THE DETAIL. THE ENTIRE CIRCUMFERENCE OF THE ASSEMBLY 90° OR LESS UNDISTURBED CONNECTION 6" MIN
CONNECTION 6" MIN SECTION A-A 6" MIN ENGINEERING SHALL BE INFILLED WITH NON-SHRINK, NON-METALLIC GROUT SOIL 45° THICKNESS TO SECURE IN PLACE. HUDSON ENGINEERING, LLC OF SEWER 2. CIRCULAR HOLE SAWS WHICH ARE APPROPRIATELY SIZED OR INFILL WITH HAND DRILLS MUST BE USED TO MAKE THE OPENINGS IN