Supporting Documentation · Nov 4, 2026
1250703StormWaterManagementReport
4e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89Indexed text
27 Fairway Drive, West Orange NOAA 24-hr D 2-Year-2050 Rainfall=4.09", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 43 Summary for Subcatchment 4S: Bypass Runoff = 0.10 cfs @ 12.09 hrs, Volume= Routed to Link 10L : Proposed 0.020 af, Depth= 1.72" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 2-Year-2050 Rainfall=4.09", P2=4.09" Area (sf) 5,974 147 6,121 5,974 147 * CN 74 98 75 74 98 Description >75% Grass cover, Good, HSG C Deck & Steps, HSG C Weighted Average 97.60% Pervious Area 2.40% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 4S: Bypass Flow (cfs) Hydrograph 0.11 0.105 0.1 0.095 0.09 0.085 0.08 0.075 0.07 0.065 0.06 0.055 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 Runoff 0.10 cfs NOAA 24-hr D 2-Year-2050 Rainfall=4.09" P2=4.09" Runoff Area=6,121 sf Runoff Volume=0.020 af Runoff Depth=1.72" Flow Length=75' Tc=3.9 min CN=74/98 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 146
27 Fairway Drive, West Orange NOAA 24-hr D 2-Year-2050 Rainfall=4.09", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 44 Summary for Pond 9P: Drywell Inflow Area = 0.050 ac, 99.35% Impervious, Inflow Depth = 3.84" for 2-Year-2050 event Inflow = 0.07 cfs @ 12.01 hrs, Volume= 0.016 af Outflow = 0.04 cfs @ 12.50 hrs, Volume= 0.016 af, Atten= 39%, Lag= 29.2 min Discarded = 0.04 cfs @ 12.50 hrs, Volume= 0.016 af Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routed to Link 10L : Proposed Routing by Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 1.00 hrs Peak Elev= 78.94' @ 12.70 hrs Surf.Area= 225 sf Storage= 85 cf Plug-Flow detention time= (not calculated: outflow precedes inflow) Center-of-Mass det. time= 17.9 min ( 768.6 - 750.7 ) Volume #1 Invert 80.00' Avail.Storage 302 cf #2 78.00' 578 cf #3 86.00' 5 cf 885 cf Device #1 #2 Routing Discarded Primary Invert 78.00' 87.67' Storage Description 8.00'D x 6.00'H Drywell Inside #2 354 cf Overall - 4.0" Wall Thickness = 302 cf 15.00'W x 15.00'L x 8.00'H Stone 1,800 cf Overall - 354 cf Embedded = 1,446 cf x 40.0% Voids 2.00'D x 1.67'H Vertical Cone/Cylinder Total Available Storage Outlet Devices 8.000 in/hr Exfiltration over Surface area 24.0" Vert. Orifice/Grate C= 0.600 Limited to weir flow at low heads Discarded OutFlow Max=0.04 cfs @ 12.50 hrs HW=78.79' (Free Discharge) 1=Exfiltration (Exfiltration Controls 0.04 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=78.00' (Free Discharge) 2=Orifice/Grate ( Controls 0.00 cfs) 147
27 Fairway Drive, West Orange NOAA 24-hr D 2-Year-2050 Rainfall=4.09", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 45 Pond 9P: Drywell Hydrograph 0.07 cfs Inflow Area=0.050 ac Peak Elev=78.94' Storage=85 cf 0.08 0.075 0.07 0.065 0.06 0.04 cfs 0.04 cfs 0.055 Flow (cfs) Inflow Outflow Discarded Primary 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 0.00 cfs 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 148
27 Fairway Drive, West Orange NOAA 24-hr D 2-Year-2050 Rainfall=4.09", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 46 Summary for Link 10L: Proposed Inflow Area = Inflow = Primary = 0.190 ac, 27.66% Impervious, Inflow Depth = 1.27" for 2-Year-2050 event 0.10 cfs @ 12.09 hrs, Volume= 0.020 af 0.10 cfs @ 12.09 hrs, Volume= 0.020 af, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-72.00 hrs, dt= 1.00 hrs Link 10L: Proposed Flow (cfs) Hydrograph 0.11 0.105 0.1 0.095 0.09 0.085 0.08 0.075 0.07 0.065 0.06 0.055 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 0.10 cfs 0.10 cfs Inflow Primary Inflow Area=0.190 ac 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 149
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 47 Time span=0.00-72.00 hrs, dt=1.00 hrs, 73 points Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing (Disturbed) Runoff Area=3,459 sf 0.00% Impervious Runoff Depth=3.50" Flow Length=75' Tc=3.9 min CN=74/0 Runoff=0.12 cfs 0.023 af Runoff Area=4,819 sf 0.00% Impervious Runoff Depth=3.50" Flow Length=75' Tc=3.9 min CN=74/0 Runoff=0.16 cfs 0.032 af Subcatchment 2S: Existing (Undisturbed) Subcatchment 3S: Propsed Runoff Area=2,157 sf 99.35% Impervious Runoff Depth=6.11" Flow Length=75' Tc=3.9 min CN=74/98 Runoff=0.11 cfs 0.025 af Subcatchment 4S: Bypass Runoff Area=6,121 sf 2.40% Impervious Runoff Depth=3.56" Flow Length=75' Tc=3.9 min CN=74/98 Runoff=0.21 cfs 0.042 af Pond 9P: Drywell Link 10L: Proposed Peak Elev=80.66' Storage=257 cf Inflow=0.11 cfs 0.025 af Discarded=0.04 cfs 0.025 af Primary=0.00 cfs 0.000 af Outflow=0.04 cfs 0.025 af Inflow=0.21 cfs 0.042 af Primary=0.21 cfs 0.042 af Total Runoff Area = 0.380 ac Runoff Volume = 0.122 af Average Runoff Depth = 3.86" 86.17% Pervious = 0.328 ac 13.83% Impervious = 0.053 ac 150
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 48 Summary for Subcatchment 1S: Existing (Disturbed) Runoff = 0.12 cfs @ 12.06 hrs, Volume= 0.023 af, Depth= 3.50" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" Area (sf) 3,459 3,459 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 1S: Existing (Disturbed) Flow (cfs) Hydrograph 0.13 0.125 0.12 0.115 0.11 0.105 0.1 0.095 0.09 0.085 0.08 0.075 0.07 0.065 0.06 0.055 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 Runoff 0.12 cfs NOAA 24-hr D 10-Year-2050 Rainfall=6.37" P2=4.09" Runoff Area=3,459 sf Runoff Volume=0.023 af Runoff Depth=3.50" Flow Length=75' Tc=3.9 min CN=74/0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 151
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 49 Summary for Subcatchment 2S: Existing (Undisturbed) Runoff = 0.16 cfs @ 12.06 hrs, Volume= 0.032 af, Depth= 3.50" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" Area (sf) 4,819 4,819 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 2S: Existing (Undisturbed) Hydrograph 0.18 NOAA 24-hr D 10-Year-2050 Rainfall=6.37" P2=4.09" Runoff Area=4,819 sf Runoff Volume=0.032 af Runoff Depth=3.50" Flow Length=75' Tc=3.9 min CN=74/0 0.16 0.15 0.14 0.13 0.12 Flow (cfs) Runoff 0.16 cfs 0.17 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 152
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 50 Summary for Subcatchment 3S: Propsed Runoff = 0.11 cfs @ 12.01 hrs, Volume= Routed to Pond 9P : Drywell 0.025 af, Depth= 6.11" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" * * Area (sf) 1,467 608 68 14 2,157 14 2,143 CN 98 98 98 74 98 74 98 Description Roofs, HSG C Driveway, HSG C Front Walk, HSG C >75% Grass cover, Good, HSG C Weighted Average 0.65% Pervious Area 99.35% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" 153
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 51 Subcatchment 3S: Propsed Flow (cfs) Hydrograph 0.125 0.12 0.115 0.11 0.105 0.1 0.095 0.09 0.085 0.08 0.075 0.07 0.065 0.06 0.055 0.05 0.045 0.04 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 Runoff 0.11 cfs NOAA 24-hr D 10-Year-2050 Rainfall=6.37" P2=4.09" Runoff Area=2,157 sf Runoff Volume=0.025 af Runoff Depth=6.11" Flow Length=75' Tc=3.9 min CN=74/98 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 154
27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 52 Summary for Subcatchment 4S: Bypass Runoff = 0.21 cfs @ 12.06 hrs, Volume= Routed to Link 10L : Proposed 0.042 af, Depth= 3.56" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" Area (sf) 5,974 147 6,121 5,974 147 * CN 74 98 75 74 98 Description >75% Grass cover, Good, HSG C Deck & Steps, HSG C Weighted Average 97.60% Pervious Area 2.40% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 4S: Bypass Flow (cfs) Hydrograph 0.23 0.22 0.21 0.2 0.19 0.18 0.17 0.16 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Runoff 0.21 cfs NOAA 24-hr D 10-Year-2050 Rainfall=6.37" P2=4.09" Runoff Area=6,121 sf Runoff Volume=0.042 af Runoff Depth=3.56" Flow Length=75' Tc=3.9 min CN=74/98 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 155
File revisions (1)
- Oct 30, 2026
4e86752994915,215,319 bytes