27 Fairway Drive, West Orange NOAA 24-hr D 25-Year-2020 Rainfall=6.72", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 28 Summary for Link 10L: Proposed Inflow Area = Inflow = Primary = 0.165 ac, 32.69% Impervious, Inflow Depth = 2.55" for 25-Year-2020 event 0.18 cfs @ 12.06 hrs, Volume= 0.035 af 0.18 cfs @ 12.06 hrs, Volume= 0.035 af, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-72.00 hrs, dt= 1.00 hrs Link 10L: Proposed Hydrograph 0.19 0.18 0.18 cfs 0.18 cfs Inflow Primary Inflow Area=0.165 ac 0.17 0.16 Flow (cfs) 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 46

Page 48

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 29 Time span=0.00-72.00 hrs, dt=1.00 hrs, 73 points Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing (Disturbed) Runoff Area=5,759 sf 34.83% Impervious Runoff Depth=7.02" Flow Length=74' Tc=5.3 min CN=74/98 Runoff=0.37 cfs 0.077 af Runoff Area=1,439 sf 0.00% Impervious Runoff Depth=5.99" Flow Length=74' Tc=5.3 min CN=74/0 Runoff=0.08 cfs 0.016 af Subcatchment 2S: Existing (Undisturbed) Subcatchment 3S: Proposed Runoff Area=2,375 sf 99.07% Impervious Runoff Depth=8.91" Flow Length=74' Tc=5.3 min CN=74/98 Runoff=0.18 cfs 0.040 af Subcatchment 4S: Bypass Runoff Area=4,824 sf 0.00% Impervious Runoff Depth=5.99" Flow Length=74' Tc=5.3 min CN=74/0 Runoff=0.28 cfs 0.055 af Pond 9P: Drywell Link 10L: Proposed Peak Elev=97.14' Storage=567 cf Inflow=0.18 cfs 0.040 af Discarded=0.04 cfs 0.041 af Primary=0.00 cfs 0.000 af Outflow=0.04 cfs 0.041 af Inflow=0.28 cfs 0.055 af Primary=0.28 cfs 0.055 af Total Runoff Area = 0.331 ac Runoff Volume = 0.190 af Average Runoff Depth = 6.89" 69.72% Pervious = 0.230 ac 30.28% Impervious = 0.100 ac 47

Page 49

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 30 Summary for Subcatchment 1S: Existing (Disturbed) Runoff = 0.37 cfs @ 12.04 hrs, Volume= 0.077 af, Depth= 7.02" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" Area (sf) 3,753 582 1,424 5,759 3,753 2,006 * CN 74 98 98 82 74 98 Description >75% Grass cover, Good, HSG C Water Surface, HSG C Patios & Walks, HSG C Weighted Average 65.17% Pervious Area 34.83% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 1.0 21 0.2520 Velocity (ft/sec) 0.36 2.0 22 0.0450 0.18 2.3 31 0.0650 0.22 5.3 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 2 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 3 Grass: Short n= 0.150 P2= 3.47" Subcatchment 1S: Existing (Disturbed) Hydrograph NOAA 24-hr D 100-Year-2020 Rainfall=9.18" P2=3.47" Runoff Area=5,759 sf Runoff Volume=0.077 af Runoff Depth=7.02" Flow Length=74' Tc=5.3 min CN=74/98 0.34 0.32 0.3 0.28 0.26 Flow (cfs) Runoff 0.37 cfs 0.4 0.38 0.36 0.24 0.22 0.2 0.18 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 48

Page 50

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 31 Summary for Subcatchment 2S: Existing (Undisturbed) Runoff = 0.08 cfs @ 12.05 hrs, Volume= 0.016 af, Depth= 5.99" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" Area (sf) 1,439 1,439 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 1.0 21 0.2520 Velocity (ft/sec) 0.36 2.0 22 0.0450 0.18 2.3 31 0.0650 0.22 5.3 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 2 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 3 Grass: Short n= 0.150 P2= 3.47" Subcatchment 2S: Existing (Undisturbed) Hydrograph 0.09 0.085 0.08 0.075 0.07 0.065 Flow (cfs) 0.06 0.055 0.05 0.045 0.04 0.035 0.03 Runoff 0.08 cfs NOAA 24-hr D 100-Year-2020 Rainfall=9.18" P2=3.47" Runoff Area=1,439 sf Runoff Volume=0.016 af Runoff Depth=5.99" Flow Length=74' Tc=5.3 min CN=74/0 0.025 0.02 0.015 0.01 0.005 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 49

Page 51

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 32 Summary for Subcatchment 3S: Proposed Runoff = 0.18 cfs @ 12.02 hrs, Volume= Routed to Pond 9P : Drywell 0.040 af, Depth= 8.91" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" * * Area (sf) 22 85 1,988 280 2,375 22 2,353 CN 74 98 98 98 98 74 98 Description >75% Grass cover, Good, HSG C Walk, HSG C Roofs, HSG B Driveway, HSG C Weighted Average 0.93% Pervious Area 99.07% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 1.0 21 0.2520 Velocity (ft/sec) 0.36 2.0 22 0.0450 0.18 2.3 31 0.0650 0.22 5.3 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 2 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 3 Grass: Short n= 0.150 P2= 3.47" 50

Page 52

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 33 Subcatchment 3S: Proposed Hydrograph 0.2 NOAA 24-hr D 100-Year-2020 Rainfall=9.18" P2=3.47" Runoff Area=2,375 sf Runoff Volume=0.040 af Runoff Depth=8.91" Flow Length=74' Tc=5.3 min CN=74/98 0.18 0.17 0.16 0.15 0.14 0.13 Flow (cfs) Runoff 0.18 cfs 0.19 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 51

Page 53

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 34 Summary for Subcatchment 4S: Bypass Runoff = 0.28 cfs @ 12.05 hrs, Volume= Routed to Link 10L : Proposed 0.055 af, Depth= 5.99" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" Area (sf) 4,824 4,824 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 1.0 21 0.2520 Velocity (ft/sec) 0.36 2.0 22 0.0450 0.18 2.3 31 0.0650 0.22 5.3 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 2 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 3 Grass: Short n= 0.150 P2= 3.47" Subcatchment 4S: Bypass Hydrograph NOAA 24-hr D 100-Year-2020 Rainfall=9.18" P2=3.47" Runoff Area=4,824 sf Runoff Volume=0.055 af Runoff Depth=5.99" Flow Length=74' Tc=5.3 min CN=74/0 0.28 0.26 0.24 0.22 0.2 Flow (cfs) Runoff 0.28 cfs 0.3 0.18 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 52

Page 54

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 35 Summary for Pond 9P: Drywell Inflow Area = 0.055 ac, 99.07% Impervious, Inflow Depth = 8.91" for 100-Year-2020 event Inflow = 0.18 cfs @ 12.02 hrs, Volume= 0.040 af Outflow = 0.04 cfs @ 12.00 hrs, Volume= 0.041 af, Atten= 77%, Lag= 0.0 min Discarded = 0.04 cfs @ 12.00 hrs, Volume= 0.041 af Primary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af Routed to Link 10L : Proposed Routing by Stor-Ind method, Time Span= 0.00-72.00 hrs, dt= 1.00 hrs Peak Elev= 97.14' @ 13.46 hrs Surf.Area= 225 sf Storage= 567 cf Plug-Flow detention time= (not calculated: outflow precedes inflow) Center-of-Mass det. time= 94.2 min ( 833.4 - 739.2 ) Volume #1 Invert 93.83' Avail.Storage 302 cf #2 91.83' 578 cf #3 99.83' 5 cf 885 cf Device #1 #2 Routing Discarded Primary Invert 91.83' 101.50' Storage Description 8.00'D x 6.00'H Drywell Inside #2 354 cf Overall - 4.0" Wall Thickness = 302 cf 15.00'W x 15.00'L x 8.00'H Stone 1,800 cf Overall - 354 cf Embedded = 1,446 cf x 40.0% Voids 2.00'D x 1.67'H Vertical Cone/Cylinder Total Available Storage Outlet Devices 8.000 in/hr Exfiltration over Surface area 24.0" Vert. Orifice/Grate C= 0.600 Limited to weir flow at low heads Discarded OutFlow Max=0.04 cfs @ 12.00 hrs HW=94.57' (Free Discharge) 1=Exfiltration (Exfiltration Controls 0.04 cfs) Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=91.83' (Free Discharge) 2=Orifice/Grate ( Controls 0.00 cfs) 53

Page 55

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 36 Pond 9P: Drywell Hydrograph Flow (cfs) 0.18 cfs 0.2 0.19 0.18 0.17 0.16 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Inflow Area=0.055 ac Peak Elev=97.14' Storage=567 cf Inflow Outflow Discarded Primary 0.04 cfs 0.04 cfs 0.00 cfs 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 54

Page 56

27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 37 Summary for Link 10L: Proposed Inflow Area = Inflow = Primary = 0.165 ac, 32.69% Impervious, Inflow Depth = 4.02" for 100-Year-2020 event 0.28 cfs @ 12.05 hrs, Volume= 0.055 af 0.28 cfs @ 12.05 hrs, Volume= 0.055 af, Atten= 0%, Lag= 0.0 min Primary outflow = Inflow, Time Span= 0.00-72.00 hrs, dt= 1.00 hrs Link 10L: Proposed Hydrograph 0.3 0.28 0.28 cfs 0.28 cfs Inflow Primary Inflow Area=0.165 ac 0.26 0.24 0.22 Flow (cfs) 0.2 0.18 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 55