Minutes · Nov 17, 2011
November 17, 2011
04bd7d4d743e29a6aa9446ff91aff55a30dab37c6f20edcf5d046f8c2e908694Indexed text · page 4
Show all pagesMr. Keller said to ignore the technical review letter #3 that he prepared for the plan that they sent him on Monday, November 14th. He said that his technical review letter #3A is for the plan that they submitted today, November 17th. Chairman Neuer asked Mr. Guzzo to address item numbers 1-10 on Mr. Keller’s technical review letter #3A. Mr. Guzzo addressed item #1 regarding the light fixture pole mounted at the north east corner. He said that if they were to move or relocate the fixture it would create a worse situation. Mr. Guzzo said that they will adjust and reduce the light levels and spillage. Mr. Keller was satisfied with Mr. Guzzo’s comment. Chairman Neuer stated that one of the conditions will be in response to item #1 of Mr. Keller’s technical review #3A in which they will have to put outside shields on the light fixture so it doesn’t spill on other properties. Mr. Guzzo addressed item #2 regarding light on the stairs for safety concerns. He said that the low light levels on the stairs are sufficient and not that low. Mr. Guzzo stated that they could add recessed step lighting or low lighting in the side walls to illuminate the stairs. Chairman Neuer stated it will be one of the conditions. Mr. Guzzo addressed item #3 regarding the lighting that will remain on from dawn to dusk. He said that they will coordinate that with the police department. Chairman Neuer stated that this will be a condition. Mr. Keller was satisfied. Mr. Guzzo addressed item #4 regarding the floodlights at the roof line. He stated that they will install wall sconces no higher than 16’ and pointed downward. Chairman Neuer stated that this will be a condition. Mr. Guzzo addressed item #5 regarding lower wattage. He stated that Mr. Keller wants to see foot candles. Mr. Guzzo stated that, subject to Mr. Keller’s approval, all wall mounted sconces wattage and bulbs reduces from 150 to 100 watts. Mr. Guzzo addressed item #6 regarding Mr. Keller not seeing a light over the door to the lower level of the building located on the Northfield Avenue side. Mr. Guzzo stated that there is a portion of the building that jets out and there are lights in there. Mr. Keller was satisfied. Mr. Guzzo addressed item #7 regarding the wattage of the bollards and clarification of the height. He stated that the bulbs will be 34 watt and they will be 36” high. Mr. Keller was satisfied and it was made a
addressed item #7 regarding the wattage of the bollards and clarification of the height. He stated that the bulbs will be 34 watt and they will be 36” high. Mr. Keller was satisfied and it was made a condition. Mr. Guzzo addressed item #8 regarding removing all of the existing floodlights on the building. He stated that they are agreeing to remove them and the final plans, which will be submitted for signature, will reflect that they have been removed. Mr. Guzzo addressed item #9 regarding the type, location and wattage of any lighting on the proposed monument sign and details of the fixture. He stated that it will be 28 watts, as stated on the plans. Mr. Guzzo also stated that the light fixture will be an up-light that will shine up at the 4
File revisions (1)
- Sep 29, 2026
04bd7d4d743e65,400 bytes