Show all pagesMr. Kliesch referred to Exhibit A-6 and detailed the building floor plan. Mr. Sussman asked Mr. Kliesch if the lifts are bolted into the concrete; he replied yes. Mr. Kliesch stated that the HVAC unit will be located on the roof and screened by a 2 % foot parapet that is being proposed. Vice Chairman Neuer asked Mr. Kliesch if the 2 % foot parapet is high enough to shield the HVAC unit; he said that the parapet will shield the unit if you are looking up at it from the street at the property line. Vice Chairman Neuer asked Mr. Kliesch if the parapet is high enough to shield it if you are looking at it from across the street; he said that someone may be able to see it from across the street. Vice Chairman Neuer asked Mr. Kliesch if they can increase the height of the parapet so that it shields the HVAC unit; he said they can but they do not like to because snow loads could accumulate. Mr. Kliesch presented the colorized elevation sheet dated 10/30/17 that was marked as Exhibit A-7 for identification and a sample board of materials that will be used on the exterior of the building that was marked as Exhibit A-8 for identification. Mr. Kliesch referred to Exhibit A-7 and Exhibit A-8 and detailed the fagade and all of the signs that are being proposed. He also referred to Exhibit A-8 and detailed all of the materials that will be used on the building. Chairman Buechler asked Mr. Kliesch when the illuminated signs will be turned off, Mr. Regan replied and said when the store closes. Mr. Kliesch presented a copy of the letter dated 1/13/18 that he sent to the Township’s Fire Official in response to recommendations made in a memo from him dated 8/10/17 that was marked as Exhibit A-9 for identification. Vice Chairman Neuer asked Mr. Kliesch why the glass on the front of the building is clear; he said for visibility. Vice Chairman Neuer stated that people will be able to see the cars on the lifts and he feels that it is not very attractive. Mr. Keller referred to the following item in his technical review memo dated 1/11/18: ¢ Item #16- Mr. Keller asked Mr. Kliesch to address the issue regarding the location of the lights that are mounted on the building because they do not match what is on the site plans; he said that the lights will be mounted at a height of twelve (12) feet and he will revise the site plans to reflect this.
File revisions (1)
- Sep 29, 2026
2ff29a5824274,789,719 bytes