Supporting Documentation · Date unavailable
PB-21-10 Altera 769 - 769 Northfield Avenue
8f56be9cacdc99f7489a19bdef8812d8fd6c0f099878cbdb6b38e08a61319083Indexed text · page 17
Show all pagesvegetation is presently stabilizing soils where a tree removal permit is submitted in connection with a development application, or a parcel upon which a new development is contemplated Dynamic Engineering (Sheet 5 ), and Landscape Plan (Phase I!) last revised 1/24/22 by Dynamic Engineering (Sheet 14) And Report last revised January 2022 by Marla L. Roller of Dynamic Engineering 25.28.8.c Disturbances of slopes of 25% or more is prohibited. Maximum disturbance area permitted is 20% for slope area of 20-25% slope. Disturbance of 35.2% of the slope area of slopes in excess of 25% and disturbance of 39.7% of the slope area of 20-25% slope. 25.28.8f(11) Retaining walls will comply with the applicable wall height requirements for the zone in which the property is located. All retaining walls greater than four feet in height shall require a variance and certification by a professional engineer that the wall was constructed in accordance with approved plans. Proposed retaining wall to exceed 4 feet. 25-14.1¢ Light poles shall not exceed a height of 18 feet above normal grade in the vicinity of the light fixture Approximately 25’ high 25.14.1d The level of illumination at ground level shall not exceed 0.5 of a footcandle at the property line, nor 0.3 of a footcandle at any property line abutting a property used by or zoned for residential use. Greater than 0.3 of a footcandle and 0.5 of a footcandle at the property lines (2.1 fc at residential property lines and 1.8 fc proposed at other property lines)
File revisions (1)
- Sep 29, 2026
8f56be9cacdc7,072,858 bytes