39. Applicant is proposing a canopy sign height of 1’ 6” where 8” is the limit for safety and navigation to the site. There is an insufficient wall area on the side of the building so the only place that a sign may be placed is the canopy. If there was a side wall then no variance would be have been required. 40. The Application requires the following variance relief from the Board: SECTION/REQUIREMENT PERMITTED/REQUIRED PROPOSED 25.8.4(d) Height of Fences and Walls used for screening 6 feet 8 feet 25- 14.3 Minimum Illumination of Foot Candle Levels 2.0 Foot-candles 0.5 Foot-candles 25-15.4.] Maximum Canopy Sign Height 8 inches 1 foot 6 inches (176”) 25-7.1 Maximum Impervious Coverage 60% (83.8% existing) 82.1% 25-8.1.a Location of Accessory Uses Not within front or side yard Parking within front and side yards 25-8.1b. Minimum Setback of Accessory Use (Parking abutting residential district) 10 feet (0 existing) 5 feet 25-8.2 Yard Encroachments Not permitted Trash enclosure in front yard (Mt. Pleasant Place) 25-8.4.c Fence Height (in side | 6 feet Existing 8 foot fence along and rear yards of nonresidential districts) loading area to be replaced in kind 25-8.15 Screening of Utility Structures Screened on 3 sides Transformer on pad not screened 25-12.3.a.1 Number of 4(1 existing) 2 Loading Spaces 25-15.4.1 Canopy Projection 6’-0” (8’- 0” existing) 8°7” 10