Show all pagesMr. Cote then returned to the overall site plan and stated that he wanted to enumerate the requested variances for the record. Mr. Cote identified the first variance as Section 25-12.1.B, concerning the minimum distance from the parking area to fencing, screening, or a structure. Mr. Cote explained that this variance occurs in proximity to the recently constructed modular structure and that the fencing is being used as a protective measure while still allowing pedestrian access adjacent to the modular building. Mr. Cote identified the next variance as the minimum number of parking spaces. He stated that 700 spaces are required, and the application is reducing the current variance from 252 spaces to 292 spaces. Mr. Cote then identified the variance under Section 25-28.0.8.0.f.11, concerning the maximum retaining wall height of four feet. Mr. Cote stated that the applicant is proposing a 21.5-foot wall. He explained that this is specifically related to the area where the upper lot improvements are being combined with the lower-level detention/retention small-scale bioretention basin needed to meet water quality and water quantity requirements for stormwater management. Mr. Cote then discussed the variance requests related to steep slopes. He referred to the steep slope exhibits contained in the plan set and identified the partial steep slope analysis with site plan overlay as drawing EX04. Mr. Cote explained that EX04 identifies the various areas of the site and the extent of the slopes within those areas. Mr. Cote explained that, from the overall perspective, the site has a transition in topography between the upper-level parking lot, lower-level parking lot, and Eagle Rock Avenue. Mr. Cote stated that the elevations change by approximately 20 to 30 feet over portions of the site. Mr. Cote explained that, in order to minimize disturbances, the applicant is imposing a wall along portions of the steep slopes. He stated that the walls will be designed and will have to be approved by the Building Department for purposes of construction. Mr. Cote then discussed the transition from the upper-level parking lot to the lower-level parking lot. He explained that the project traverses a slope and that, in order to smooth the slope and create a drivable exit maneuver, walls and roadway improvements are required through portions of the steep slopes. Mr. Cote
at the project traverses a slope and that, in order to smooth the slope and create a drivable exit maneuver, walls and roadway improvements are required through portions of the steep slopes. Mr. Cote similarly discussed the area along Eagle Rock Avenue where the project is leveling the steeper slope that currently exists from the curb line to the top of the slope. Mr. Cote explained that the applicant is pulling that slope back and imposing a retaining wall along the length of the area to create a safe zone adjacent to the roadway. Mr. Cote stated that, from a steep slopes perspective, 0.38 acres of disturbance are associated with the total of 3.8 acres of areas containing slopes of 25% or greater. Mr. Cote explained that the disturbance is associated with minimizing disturbance, allowing roadway access to proceed through the site, and allowing for the proper design of the off-site roadway, Eagle Rock Avenue. Mr. Cote then identified the last variance as the maximum driveway slope under Section 25-28.f.8. Mr. Cote stated that 6% is allowed, while the proposal includes a combination of 8.5% and 10.5% grades. He explained that the 10.5% grade is the existing condition and the 8.5% grade is on the main driveway. Mr. Cote explained that the difficulty on the site is connecting the grades at a county- compliant access point to Eagle Rock Avenue. 28
File revisions (1)
- Nov 3, 2026
06070d63f2cc21,327,306 bytes