Minutes · Sep 2, 2026
September 2, 2026 Planning Board Regular Meeting Minutes
c1f7e5511657d93034ad90221a54ba2efb11fc0bf13267113440e8e4f5b73af7Indexed text · page 19
Show all pagesMr. Moronski explained that the proposed 3-foot setback would allow a guardrail and fence to be installed along the eastern side of the proposed parking area adjacent to the modular building. He stated that these protective measures would address safety concerns for vehicular and pedestrian circulation along the retaining wall. Mr. Moronski next addressed Section 25-12.2.B.1, concerning the minimum number of required parking spaces. He.explained that the golf clubhouse is a permitted principal use and is classified asia private club for parking calculations. The ordinance requires one ) parking space for every 45 square feet of gross floor area. Mr)Moronski stated that the ordinance calculation requires 700 parking spaces for the facility, while 256 spaces currently exist, representing an existing nonconforming condition. He stated that the applicant proposes 292 spaces, including electric vehicle parking credits under which four electric vehicle spaces are counted as two spaces each. Mr. Moronskirexplained that the applicant was seeking a C2 variance for the parking requirement. He stated that the driveway reconfiguration would create an opportunity to providevadditional parking abthe upper level, closer to the main country club facility, to support activities at Crestmont Country Club. Mr. Moronski stated:that:the proposal would increase the number of parking spaces by 36, reducing the existing: parking deficiency. He described the ordinance requirement of 700 spaces as‘excessive for the country club's actual needs and the nature of the site. He .cexplained that providing that number of spaces was neither necessary nor desirable, particularly given the applicant's efforts to minimize disturbance to the property. Mr. Moronski:stated that, under the C2 criteria, the additional parking spaces would improve the existirg nonconforming condition and represent an overall enhancement to the property. Mr. Moronski next addressed the maximum retaining wall height variance. He stated that the ordinance:permits retaining walls up to 4 feet in height, while the proposed improvements 'include'more than 1,300 linear feet of retaining walls, with a maximum height of approximately 21.5 feet. Mr: Moronski‘explained that the maximum wall height occurs near the stormwater management basin:and js necessary to maintain the elevation of the upper parking lot. He statdd that
oximately 21.5 feet. Mr: Moronski‘explained that the maximum wall height occurs near the stormwater management basin:and js necessary to maintain the elevation of the upper parking lot. He statdd that the requested variance could be granted under the C1 criteria, specifically CIB, because of the exceptional topographic conditions of the property. Mr. Moronski stated: that the proposed retaining wall heights are necessary to overcome the site's existing topography: He explained that attempting to meet the 4-foot maximum would:réequiréa:greater number of retaining walls, additional site disturbance, and potentially the removal of more trees. Mr. Moronski stated that the proposed design was intended to strike a balance between minimizing disturbance and addressing drainage and roadway improvement needs. He explained that the retaining walls would help limit the amount of land disturbance and tree removal while accommodating the stormwater improvements and the new driveway. Mr. Moronski stated that the elevation at the proposed signalized intersection on Eagle Rock Avenue is approximately 538, while the existing and proposed upper parking areas range from elevations 557 to 565. He explained that the parking areas are approximately 20 to 30 feet higher than the roadway, creating the need for taller retaining walls to accommodate the grade difference while minimizing disturbance. Mr. Moronski stated that the retaining walls would help create the new exit driveway and intersection along Eagle Rock Avenue, which he described as a significant safety improvement over the existing condition. Mr. Moronski next addressed the requested variances related to the Township's topographic and steep slope requirements. He stated that the variances were
File revisions (1)
- Nov 6, 2026
c1f7e551165725,244,207 bytes