Traffic Impact Study Proposed Popeye’s & Fast Food Restaurant – West Orange SITE PLAN Site Access and Circulation The site plan was reviewed with respect to the site access and on-site circulation design. As noted previously, access to The Project will be provided via one (1) full movement driveway and one (1) full movement ingress/right turn egress driveway along Eagle Rock Avenue. The newly constructed parking lot will be serviced by parking aisles with a width of 18 feet for one- way circulation with 60-degree parking and 24 feet for two-way circulation with 90-degree parking, both of which meet the Ordinance requirements. These dimensions are also consistent with accepted engineering design standards and as such will adequately accommodate the anticipated site traffic. The drive-thru lanes will operate in a counter clockwise direction with the ability to stack ten (10) cars in the drive-thru lane for both restaurants, which exceeds the Ordinance requirement of six (6) total vehicles for fast food restaurant uses. The drive-thru lanes are proposed to be 12 feet wide, which exceeds the Ordinance requirement of 9 feet. Therefore, the proposed drive-thru design will provide more than enough stacking for the maximum anticipated demand and will adequately accommodate the anticipated site traffic. An 11-foot-wide bypass lane will also be provided to ensure adequate and efficient circulation and to ensure that drive-thru queues do not impact on site circulation for patrons who park and walk in to the restaurant. Parking The Township of West Orange Ordinance sets forth a parking requirement of 1 space per 3 seats or 1 space per 45 SF of floor area available to patrons, whichever is greater. Based on square footage, this equates to a parking requirement of 31 spaces for the proposed 1,381 SF of total restaurant area available to patrons. Based on number of seats, this equates to a parking requirement of 24 spaces for the proposed 72 total seats. As such, the requirement of 31 spaces based on square footage was utilized. The site as proposed provides 31 parking spaces, and as such the Ordinance requirement is met. It is proposed to provide parking stalls with dimensions of 9’x18’ for both 60-degree and 90-degree parking which meets the minimum Ordinance

Page 9

ing spaces, and as such the Ordinance requirement is met. It is proposed to provide parking stalls with dimensions of 9’x18’ for both 60-degree and 90-degree parking which meets the minimum Ordinance requirements. It should also be noted that industry standards recommend stall widths of between 8’9” and 9’ and a length of 18’ for high-turnover land uses such as The Project, which is met as designed. Page 8

File revisions (1)