Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Feb 9, 2023

V4 06 Response to Board Engineers Review 2 1 26 2023

Preserved file SHA-2567bfc402fe296a4bad8e19f879b231737b83159b9b84647187d1c3bc553a885d3

Indexed text · page 12

Show all pages
Page 12

SSS-B Series Poles SQUARE STRAIGHT STEEL currentlighting.com/beacon © 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.Page 1 of 4 Rev 05/17/22 spec_sheet_sss_pole_beacon_R01 APPLICATIONS • Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location CONSTRUCTION • SHAFT: One-piece straight steel with square cross section, flat sides and minimum 0.23" radius on all corners; Minimum yield of 46,000 psi (ASTM-A500, Grade B); Longitudinal weld seam to appear flush with shaft side wall; Steel base plate with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ASTM A36) • BASE COVER: Two-piece square aluminum base cover included standard • POLE CAP: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available • HAND HOLE: Rectangular 3x5 steel hand hole frame (2.38" x 4.38" opening); Mounting provisions for grounding lug located behind gasketed cover • ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling Anchor bolt part numbers: 3/4 x 30 x 3 — TAB-30-M38 1 x 36 x 4 — TAB-36-M38 FINISH • Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness • Powder paint prime applied over “white metal” steel substrate cleaned via mechanical shot blast method • Decorative finish coat available in multiple standard colors; Custom colors available; RAL number preferable WAREHOUSE ‘STOCKED’ POLES: • SSSH20-40A-4-HV-DB-RDC, SSSH25-40A-4-HV-DB-RDC and SSSH30-50B-4-HV-DB-RDC • The HV designation in the above catalog numbers is a combination drill pattern of the Current S2 pattern and the Beacon B3/B4 Viper pattern (rectangular arm mounting) Overall Height 10' - 40' Handhole 18" ORDERING INFORMATION BASE DETAILPOLE CAP TENON BASE COVER SERIES SSS-B Square Straight Steel Pole Beacon SSS B 25 40 A/B/C 2L BLTB3 UL 1 Removable tenon used in conjunction with side arm mounting. First specify desired arm configuration followed by the “TR” notation. Example:

Page 12

e Straight Steel Pole Beacon SSS B 25 40 A/B/C 2L BLTB3 UL 1 Removable tenon used in conjunction with side arm mounting. First specify desired arm configuration followed by the “TR” notation. Example: SSS-B-25-40-A-1-B1-TR-BBT 2 Specify option location using logic found on page 2 (Option Orientation) 3 VM1 recommended on poles 20’ and taller with EPA of less than 1. MOUNTING ORIENTATION HEIGHT Reference page 2 Ordering matrix SHAFT Reference page 2 Ordering matrix THICKNESS Reference page 2 Ordering matrix OPTIONS GFI2 20 Amp GFCI Receptacle and Cover EHH2 Extra Handhole C052 .5” Coupling C072 .75” Coupling C202 2” Coupling MPB2 Mid-pole Luminaire Bracket VM2 2nd mode vibration damper LAB Less Anchor Bolts UL UL Certified ORDERING EXAMPLE: Reference page 2 for available configurations Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Anchor Base Detail Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Bolt Circle Bolt Slots/Holes 0°-Handhole Bolt Square 270° Arm 1 90° Arm 2 180° As viewed from top of pole. Overall Height 10'-30' 18" TENON Bolt Circle (Outer) Bolt Circle (Inner) Bolt Square (Outer) Bolt Square (Inner) Height of option in feet BASE COVER 270˚ 90˚ 180˚ 0˚ Handhole VIBRATION DAMPER 2ND MODE ACCESSORIES - Order Separately Catalog Number Description VM13 1st mode vibration damper VM2SXX 2nd mode vibration damper MOUNTING 1 Single arm mount 2 Two fixtures at 180˚ 2L Two fixtures at 90˚ 3T Three fixtures at 90˚ 4 Four fixtures at 90˚ TA Tenon (2.38” OD x 4” Tall) TB Tenon (2.88” OD x 4” Tall) TC Tenon (3.5” OD x 6” Tall) TR1 Removable Tenon (2.375 x 4.25) OT Open Top (in- cludes pole cap) TOP VIEW DRILL PATTERN B1 Cruzer, “AM” arm B3 2 bolt (2-1/2” spacing), Viper “A” arm S2 2 bolt (3-1/2” spacing), Viper “AD” arm FINISH BLT Black Matte Textured BLS Black Gloss Smooth DBT Dark Bronze Matte Textured DBS Dark Bronze Gloss Smooth GTT Graphite Matte Textured LGS Light Grey Gloss Smooth PSS

Page 12

spacing), Viper “AD” arm FINISH BLT Black Matte Textured BLS Black Gloss Smooth DBT Dark Bronze Matte Textured DBS Dark Bronze Gloss Smooth GTT Graphite Matte Textured LGS Light Grey Gloss Smooth PSS Platinum Silver Smooth WHT White Matte Textured WHS White Gloss Smooth VGT Verde Green Textured Color Option CC Custom Color Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 Denotes handhole location 1 2L 2 3T 3Y 4 DATE: LOCATION: TYPE: PROJECT: CATALOG #:

File revisions (1)