Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Feb 9, 2023

V4 15 Architectural Plans 1 30 2023

Preserved file SHA-256d9eaa4c5f8012ca6a20f5e845bdbd3b5e2c303045f7057a887081df452b5d4ef

Indexed text · page 12

Show all pages
Page 12

MAIN LEVEL EL. 427.20' CEMENT BD. PANEL CLADDING, COLOR: TBD 4" BRICK VENEER COLOR: TBD ROOF LEVEL EL. 478.56' MAIN LEVEL EL. 427.20' LOWER LEVEL EL. 414.53' AV. GRADE EL. 422.29' ROOF LEVEL EL. 480.06' AV. GRADE EL. 422.29' CALCULATED PHASE 1, H.C. BUILDING HEIGHT: 480.06' TOP OF ROOF -422.29' AVERAGE BUILDING GRADE 57.77' CALCULATED ILU BUILDING PHASE 2 AND 3 HEIGHT: 478.56' TOP OF ROOF -422.29' AVERAGE BUILDING GRADE 56.27' MAIN LEVEL EL. 427.20' LOWER LEVEL EL. 414.50' AV. GRADE EL. 422.29' MAIN LEVEL EL. 427.20' ROOF LEVEL EL. 480.06' AV. GRADE LEVEL EL. 422.29' ROOF LEVEL EL. 478.56' CEMENT BD. PANEL CLADDING, COLOR: TBD 4" BRICK VENEER COLOR: TBD MAIN LEVEL EL. 427.20' ROOF ELEV. EL. 480.06' AV. GRADE EL. 422.29' 1/2.1 2/2.0 3/2.0 3/2.1 2/2.1 1/2.0 BOTTOM OF STAIRCASE REQUIRES PAD SUPPORT AT SAME HEIGHT OF TANK BOTTOM GENERATOR END 8' - 8" EXTEND NORMAL VENT GENERATOR SIDE VIEW 15' - 8" 3' - 6" 5' - 0" 30' - 6" AIR INAIR OUT 7008 GALLON SUB BASE TANK 11'-6" 23' - 8" GENERATOR 7' - 1" PEA GRAVEL TO 3 FT. HORIZONTALLY ALL AROUND TANK (OR APPROVED EQUIVALENT COMPACTED TO 98% SPD) OUTLET INSTALL SECOND TANK 2" LOWER TO MATCH OUTLET OF FIRST TANK CAST-IN-PLACE 3000 PSI CONCRETE READY MIX. POUR 12" ALL AROUND BASE OF UNIT. 58 CU FT MINIMUM PER TANK (BASED ON 130 LBS / CU FT CONCRETE DENSITY) CONNECT TANK TOP VENTS (4) TO VENTING SYSTEM (SEE ALSO NOTE 2) CONNECTION ON SITE C/O (4) INLET 24" FRAME AND COVER (2) SECURED IN CONCRETE MIN. 6" PEA GRAVEL (OR APPROVED BACKFILL COMPACTED TO 98% SPD) 12" ALL AROUND TANK *ACTUAL HEIGHT MAY VARY SECTION TOP VIEW CONNECTION ON SITE OUTLETINLET 2" 6' - 11" 1' - 6" MIN. BURIAL DEPTH: 18" MIN WITH TRAFFIC 12" MIN WITHOUT TRAFFIC 6 FT MAX ACCESSWAY (2) 3" VENT PORT (4) 8' - 0" 5' - 2" 8'-0" 4'-2" 1' - 5 1 2" 1'-0" SIDE VIEWFRONT VIEW TOP VIEW EXTERIOR ELEVATIONS A2.1 NORTH ELEVATION SCALE: 1" =20'-0" 1 A.2.1 PARTIAL WEST ELEVATION SCALE: 1" =20'-0" 2 A.2.1 PARTIAL WEST ELEVATION SCALE: 1" =20'-0" 3 A.2.1 North KEY PLAN N.T.S Proj. No: ISSUES REVISIONS 1304.01.02 Issued For: Date: 10-21-2021 Site Plan Application 1155 Pleasant Valley Way West Orange NJ 07052 · · DAVID S. FOWLES, AIA 500 Kings Highway South Cherry Hill, NJ 08034 856.770.1060 office@ kd-arch.com architects KDA GENERATOR DETAIL SCALE: 3/16" =1'-0" 4 A.2.1 GREASE INTERCEPTOR DETAIL SCALE: 3/8" =1'-0" 5 A.2.1 EV CHARGING STATION DETAIL SCALE: 1/2" =1'-0" 6 A.2.1

File revisions (1)