Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Aug 15, 2024

J_2024 05 09_West Orange Stormwater Management Plan

Preserved file SHA-256c30154c5b2e926fb3bf094c58f5df7b46c6e758698d66ce7ef1e45733c103a5e

Indexed text · page 1025

Show all pages
Page 1025

Outlet Description Orifice Orifice Outlet Pipe (Other) Outlet Type Orifice Orifice Outlet Pipe Orifice Size / Weir Length Invert Elevation 2.5” DIA 12” DIA 18” DIA 164.75 167.25 164.75 9. Vegetation o The vegetation type to be used in this bioretention system is site-tolerant grasses. A Landscaping Plan should be included in the Reference Documents section of this field manual. For a bioretention system designed with an underdrain, the following also applies. 10. Underdrain o The perforated laterals are ____6____ inches in diameter, at a slope of 0.50%. o There are 4 lateral pipes in the basin. Each lateral is approximately 25 feet long. o The perforations are 0.25 inches in diameter and designed per ASTM D2729. o The gravel layer surrounding the underdrain consists of 3 inches of gravel above the underdrain and 3 inches of gravel below the underdrain. Critical Maintenance Features 1. No heavy equipment on the basin surface. 2. Remove vegetation strictly in accordance with the landscaping plan. 3. Grass clippings shall be collected from the basin and properly disposed. 4. Keep the appearance of the basin aesthetic. 5. The system of pop-up drainage emitters and perforated dispersion pipes shall be inspected for blockages when the bioretention basins are inspected. April 2015 Bioretention System Page 29/49

File revisions (1)