Supporting Documentation · Aug 15, 2024
J_2024 05 09_West Orange Stormwater Management Plan
c30154c5b2e926fb3bf094c58f5df7b46c6e758698d66ce7ef1e45733c103a5eIndexed text · page 1092
Show all pagesDESIGN FOUNDATION SUBGRADE LEVEL SUITABLE NATURAL BEARING STRATUM ALTERNATE MIN. LIMITS OF BOTTOM OF FOUNDATION EXCAVATIONS DETERMINED BY LEAN CONCRETE, FLOWABLE TYPE OF BACKFILL MATERIAL FILL OR STRUCTURAL BACKFILL B+1" STONE BACKFILL SUGGESTED FOUNDATION OVEREXCAVATION DETAIL NOT TO SCALE = Width of foundation. = Depth of overexcavation of unsuitable materials below bottom of foundation subgrade to surface of suitable bearing stratum. Lean Concrete: Minimum 2,000 psi. Stone Backfill: Clean 3/4 inch crushed stone or washed gravel; separate stone from adjacent soils on sides and bottom using filter fabric (Mirafi 140, or equivalent). Structural Fill Backfill: Approved granular soils spread in lifts on the order of 6 to 8 inches in loose thickness and compacted to at least 95 percent of maximum dry density as determined by the ASTM D1557 test procedure. Ny PLATE 10
File revisions (1)
- Sep 29, 2026
c30154c5b2e9131,201,955 bytes