Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Aug 15, 2024

J_2024 05 09_West Orange Stormwater Management Plan

Preserved file SHA-256c30154c5b2e926fb3bf094c58f5df7b46c6e758698d66ce7ef1e45733c103a5e

Indexed text · page 125

Show all pages
Page 125

Post-Developed (O-1) West Orange HydroCAD_Pre NOAA 24-hr D 2-Year_Current Rainfall=3.45", P2=3.45" Prepared by Burns & McDonnell Printed 5/13/2024 Page 8 HydroCAD® 10.20-4b s/n 08510 © 2023 HydroCAD Software Solutions LLC Subcatchment 24S: PO-DA 7 Hydrograph Runoff 2.66 cfs NOAA 24-hr D 2-Year_Current Rainfall=3.45" P2=3.45" Runoff Area=73,407 sf Runoff Volume=0.239 af Runoff Depth>1.70" Flow Length=439' Tc=12.1 min CN=WQ Flow (cfs) 2 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Time (hours) 15 16 17 18 19 20 21 22 23 24

File revisions (1)