Show all pagesPost Development West Orange B_03 01 12 Prepared by TRC Engineers, Inc. HydroCAD® 9.10 s/n 06401 © 2009 HydroCAD Software Solutions LLC Printed Page 2 3/14/2012 Pipe Listing (all nodes) Line# Node Number In-Invert (feet) Out-Invert (feet) Length (feet) Slope (ft/ft) n Diam/Width (inches) Height (inches) Fill (inches) 1 2 3 4 5 6 7 8 9 10 MH-1 MH-2 MH-3 MH-4 MH-5 MH-6 MH-7 MH-A MH-B MH-C 603.20 604.00 603.20 602.20 599.90 597.60 596.50 599.00 598.00 597.00 602.20 603.20 602.20 599.90 597.60 596.50 592.80 598.00 597.00 592.70 15.0 34.0 50.0 85.0 66.0 45.0 360.0 74.0 92.0 205.0 0.0667 0.0235 0.0200 0.0271 0.0348 0.0244 0.0103 0.0135 0.0109 0.0210 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 12.0 12.0 12.0 18.0 18.0 18.0 30.0 12.0 12.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0