Supporting Documentation · Aug 15, 2024
J_2024 05 09_West Orange Stormwater Management Plan
c30154c5b2e926fb3bf094c58f5df7b46c6e758698d66ce7ef1e45733c103a5eIndexed text · page 576
Show all pagesPost-Developed (O-1B) NJ DEP 2-hr WQ Rainfall=1.25", P2=3.42" West Orange HydroCAD_Post Prepared by Burns & McDonnell HydroCAD® 10.20-4b s/n 08510 © 2023 HydroCAD Software Solutions LLC Printed 5/13/2024 Page 19 Summary for Pond 1P: BR-01 Inflow Area = 0.567 ac, 17.46% Impervious, Inflow Depth = 0.42" for WQ event Inflow = 0.44 cfs @ 1.29 hrs, Volume= 0.020 af Outflow = 0.12 cfs @ 1.80 hrs, Volume= 0.020 af, Atten= 71%, Lag= 30.6 min Primary = 0.12 cfs @ 1.80 hrs, Volume= 0.020 af Routed to Pond 19P : SD-21 Routing by Dyn-Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.0100 hrs Peak Elev= 596.68' @ 1.80 hrs Surf.Area= 1,759 sf Storage= 487 cf Plug-Flow detention time= 64.5 min calculated for 0.020 af (100% of inflow) Center-of-Mass det. time= 64.2 min ( 151.6 - 87.4 ) Volume #1 #2 Invert 598.00' 597.50' Avail.Storage 5,850 cf 330 cf #3 596.00' 1,051 cf #4 596.00' 11 cf 7,241 cf Storage Description Filter Media Layer (Prismatic)Listed below (Recalc) Sand Layer (Prismatic)Listed below (Recalc) 880 cf Overall x 37.5% Voids Gravel Layer (Prismatic)Listed below (Recalc) 2,639 cf Overall - 11 cf Embedded = 2,627 cf x 40.0% Voids 4.0" Round 4" Underdrain Pipe Inside #3 L= 127.3' S= 0.0001 '/' Total Available Storage Elevation (feet) 598.00 599.50 602.50 Surf.Area Voids (sq-ft) (%) 1,759 0.0 1,759 21.7 1,759 100.0 Elevation (feet) 597.50 598.00 Surf.Area (sq-ft) 1,759 1,759 Inc.Store (cubic-feet) 0 880 Cum.Store (cubic-feet) 0 880 Elevation (feet) 596.00 597.50 Surf.Area (sq-ft) 1,759 1,759 Inc.Store (cubic-feet) 0 2,639 Cum.Store (cubic-feet) 0 2,639 Device #1 Routing Primary Invert 591.57' #2 Device 1 596.00' #3 Device 1 600.50' #4 Device 1 602.40' Inc.Store (cubic-feet) 0 573 5,277 Cum.Store (cubic-feet) 0 573 5,850 Outlet Devices 12.0" Vert. SD-21 Outlet (Elevation F) C= 0.600 Limited to weir flow at low heads 2.5" Vert. Water Quatity (Elevation G) C= 0.600 Limited to weir flow at low heads 12.0" W x 2.5" H Vert. Water Quantity (Elevation H) C= 0.600 Limited to weir flow at low heads 48.0" x 48.0" Horiz. Overflow Grate (Elevation I) C= 0.600 Limited to weir flow at low heads
File revisions (1)
- Sep 29, 2026
c30154c5b2e9131,201,955 bytes