Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Aug 15, 2024

J_2024 05 09_West Orange Stormwater Management Plan

Preserved file SHA-256c30154c5b2e926fb3bf094c58f5df7b46c6e758698d66ce7ef1e45733c103a5e

Indexed text · page 583

Show all pages
Page 583

Post-Developed (O-1B) NJ DEP 2-hr WQ Rainfall=1.25", P2=3.42" West Orange HydroCAD_Post Printed 5/13/2024 Page 26 Prepared by Burns & McDonnell HydroCAD® 10.20-4b s/n 08510 © 2023 HydroCAD Software Solutions LLC Primary OutFlow Max=0.10 cfs @ 1.87 hrs HW=594.44' TW=587.06' (Dynamic Tailwater) 1=SD-23 Outlet (Elevation F) (Passes 0.10 cfs of 14.01 cfs potential flow) 2=Water Quatity (Elevation G) (Orifice Controls 0.10 cfs @ 2.79 fps) 3=Water Quantity (Elevation H) ( Controls 0.00 cfs) 4=Overflow Grate (Elevation I) ( Controls 0.00 cfs) Pond 3P: BR-03 Hydrograph 0.34 Inflow Primary 0.31 cfs Inflow Area=0.388 ac Peak Elev=594.44' Storage=405 cf 0.32 0.3 0.28 0.26 0.24 Flow (cfs) 0.22 0.2 0.18 0.16 0.14 0.12 0.10 cfs 0.1 0.08 0.06 0.04 0.02 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Time (hours) 15 16 17 18 19 20 21 22 23 24