Supporting Documentation · Sep 11, 2024
Geotech Report 04 19 2021
Preserved file SHA-256
6901d4a540ff63c74d2c8a091c5acd81421e6be879d77bd5f453e4a5b3d5e1a3Indexed text · page 36
Show all pagesSOR CONSULTING ENGINEERS, INC. TEST PIT LOG TEST PIT NO. TP-1 CLIENT: Garden Homes GSE +602' (+) WATERLEVEL * PROJECT: Proposed Residential Development DATE 3/25/2021 LOCATION: West Orange, New Jersey JOB NO. 21-C-01 REPORT NO. 21-C-12 oer | DENSITY MOISTURE DESCRIPTION REMARKS Topsoil 8" 4 Soft Moist Olive brown Clayey Silt, some medium to fine Sand 2'-0" 3 Medium Moist Dense 8 Bedrock at 8° Brown coarse to fine Sand, some Sil, little coarse to fine Gravel *Water seepage @ 3° 12 13 14 Test Pit Completed at 8'-0" EXCAVATOR: _D. Willis Excavating EQUIPMENT: Backhoe SCE REPRESENTATIVE: _Atilla Sencar/Tim Maravegias
File revisions (1)
- Sep 29, 2026
6901d4a540ff5,046,636 bytes