Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Oct 17, 2024

Affidavit of Publication Mailing w Exhibits PSEG West Orange 10 17 24 Hearing

Preserved file SHA-256891cac9df20bda8c7fe13ff45dbcb429598a0c89d6301150cbcaa96dcf4fc23f

Indexed text · page 4

Show all pages
Page 4

LEGAL NOTICE TOWNSHIP OF WEST ORANGE ZONING BOARD OF ADJUSTMENT SPECIAL HEARING PLEASE TAKE NOTICE that on October 17, 2024 at 8:00 P.M., a remote public hearing will be conducted before the Township of West Orange Zoning Board of Adjustment (the “Zoning Board” or “Board”) for a preliminary and final major site plan application with variance relief filed by Public Service Electric & Gas Company (the “Applicant”), in connection with property located at 325 Mount Pleasant Avenue and designated as Block 155, Lot 26.01 on the Tax Map of the Township of West Orange, New Jersey (the “Tax Map”) (the “Property”). The Property is located within the O-R Office Research District (the “O-R Zone”), the Planned Unit Residential Development (PURD) Zone (the “PURD Zone”) and the R-5 Single Family Residential Zone (the “R-5 Zone”). The station yard and a portion of the transmission ROW are located within the O-R Zone. The Applicant previously appeared before the Zoning Board on August 15, 2024, September 12, 2024 and September 19, 2024 in connection with this application. The Property is presently developed with the West Orange Switching Station (the “Station”), which is operated by the Applicant. The Station contains specialized electrical equipment and is currently used as a public utility installation-electric substation. The Station consists of several buildings: a multi-story brick building, a one-story control house and two (2) single-story buildings. The Station has been in operation for almost one hundred (100) years and will remain a public utility following completion of the proposed improvements. The Applicant proposes to demolish small, existing one (1) story buildings on the Property and to install a new one (1) story 26kV switchgear enclosure to house the addition of a 26kV switchgear and feeder reactors. Additionally, the Applicant proposes new drive paths to be located in the southeast corner of the station yard. The Applicant also proposes to remove the existing perimeter fence and replace it with a new eight (8) foot tall fence along Mount Pleasant Avenue (State Highway Route 10) and Prospect Avenue (County Route 577). Finally, the Applicant proposes install a series of small-scale bioretention basins to the east of the new equipment and to construct six (6) 70-foot tall lightning masts to protect the new equipment from lightning strikes. The Applicant is

Page 4

a series of small-scale bioretention basins to the east of the new equipment and to construct six (6) 70-foot tall lightning masts to protect the new equipment from lightning strikes. The Applicant is proposing to utilize temporary construction trailers on the Property for the duration of the installation of the improvements discussed above. Section 25-7.1, Attachment 2, Table of District Regulations, Part A: Permitted Uses Table of District Regulations of The Land Use Regulations of the Township of West Orange (the “Land Use Regulations”) does not list “Public Utility Buildings or Structures” as a permitted use. As discussed above, the Applicant is proposing new equipment in the Station and a number of other improvements. As a result, the Applicant seeks variance relief pursuant to N.J.S.A. 40:55D-70.d.(2) to allow for the expansion of such nonconforming use. Section 25- 7.1, Attachment 3, Table of District Regulations, Part B: Bulk Standards of the Land Use Regulations provides that the maximum permitted height is 2.5 stories and not exceeding 35 feet. The Applicant proposes to install six (6) 70-foot lightning masts, when measured to the adjacent finished grade, and some ancillary utility equipment (bus supports and lightning finials) over 35 feet. As a result, the Applicant seeks variance relief pursuant to N.J.S.A. 40:55D-70.d.(6). The Applicant also seeks the following additional bulk variance relief from Section 25-7.1, Attachment 3, Table of District Regulations, Part B: Bulk Standards pertaining to the O-R Zone: (1) a variance from the requirement that the front yard and side yard setback of corner lots must be a minimum of 100 feet, whereas the Applicant proposes front yard setback along Mount Pleasant Avenue (State Highway Route 10) to be 77.9 feet and (2) a variance from the requirement that the maximum permitted lot coverage is 30%, whereas the Applicant 4859-5340-2605.v1

File revisions (1)