Supporting Documentation · Dec 4, 2024
IMMC MINOR SITE PLAN REVIEW replacement pages MSPR 41 MSPR 3
525a4077bd3b07cd4a7091f96ac77f237504bbd8612148b0b0eceb34085a4f7aIndexed text · page 2
Show all pagesTO THE BEST OF MY KNOWLEDGE AND ABILITY, THESE PLANS ARE DRAWN IN COMPLIANCE WITH OWNERS / CLIENTS SPECIFICATIONS AND THE AUTHORITY HAVING JURISDICTION OVER THIS PROJECT. ANY REQUESTED DESIGN CHANGES MADE AFTER PRINTING OR CONSTRUCTION PERMIT WILL BE AT THE OWNER'S / CLIENTS EXPENSE. SQUARE CENTER LLC IS NOT LIABLE FOR ERRORS ONCE CONSTRUCTION BEGINS. WHILE EVERY HAS BEEN MADE IN THE PREPARATION OF THESE DOCUMENTS TO AVOID MISTAKES, ERRORS, OR OMISSIONS. SQUARE CENTER LLC, CAN NOT GUARANTEE AGAINST HUMAN ERROR. THE CONSTRUCTION CONTRACTOR OF THIS PROJECT IS RESPONSIBLE FOR THE REVIEW, VERIFYING AND UNDERSTANDING ALL DETAILS AND DIMENSIONS AND SEEK WRITTEN ANSWERS OR DIRECTION FROM SQUARE CENTER LLC PRIOR TO THE START OF CONSTRUCTION OR SHALL BE SOLELY RESPONSIBLE THEREAFTER. THESE DRAWINGS, IDEAS, AND CONCEPTS ARE THE SOLE PROPERTY OF SQUARE CENTER LLC, DEVELOPED FOR THE REFERENCED CLIENT AS INSTRUMENTS OF SERVICE. USE OF THESE DRAWINGS, IDEA AND CONCEPTS CONTAINED HEREIN WITHOUT THE WRITTEN PERMISSION FOR SQUARE CENTER LLC. IS AN INFRINGEMENT OF ARCHITECTURAL COPYRIGHT LAW, AND WILL BE PROSECUTED. CONTRACTOR SHALL STRICTLY ADHERE TO THESE DOCUMENTS, CHANGES ARE PERMITTED ONLY WITH THE REVIEWED AND APPROVED FROM SQUARE CENTER LLC PRIOR INSTALLATION. ALL DESIGN MODIFICATIONS / WORK PREFORMED WITHOUT APPROVAL FROM SQUARE CENTER LLC SHALL BE CORRECTED AT CONTRACTORS EXPENSE. ELECTRICAL SYSTEM CODE: SEC.2701 MECHANICAL SYSTEM CODE: SEC.2801 PLUMBING SYSTEM CODE: SEC.2901 CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. 1 0 1 2 3 R30.00 O O 32'-11" 12'-7" 31'-1 1 24'-11 9/16 9'-2 1/8" 8'-9 13/16" 30'-8 1/8" 41'-8 3/8" 7'-4"7'-4"11'-4"10'-9 1/2" 7' 2'-4 3/8" 2'-2 9/16" 8" 8" 8" 6" 8" 4'-8" 0' 2'-5" 3" 31'-7 13/16" 25'-5 1/4" 2'-5" 29'-10" 25'-6 1/16" 2'-5" 9'-9" 19" 4'-8" 11'-7" 4'-9" 9' 11'-4" 3'-11" 4'-9" 13'-6" 5' 11'-7" 5'-11" 6'-6" 28'-2"6'-2"2'-10" 24' 12" 9'-10" 43'-1 11/16" 23'-5 3/8" 5' 10'-2" 12'-8" 14'-6" 15'-2" 14'-10" 8'-3" 6' 9'-11" 20' 20' 20'-4" 2'-5" 11'-5 15/16" 62'-11 1/4" 5'-10 9/16" 2'-5" 2'-5" 4" PASS DR P.O.B. PLEASANT VALLEY WAY (VARIABLE) Fu parkin space (8 x 16ft) Standard size parking space (9ft x 18ft) Proposed Main Entrance Electric Vehicle size parking space (9ft x
9/16" 2'-5" 2'-5" 4" PASS DR P.O.B. PLEASANT VALLEY WAY (VARIABLE) Fu parkin space (8 x 16ft) Standard size parking space (9ft x 18ft) Proposed Main Entrance Electric Vehicle size parking space (9ft x 18ft) Staff parking ADA Van Parking 11'X 18' Staff Parking Compact size parking space (2) (8ft x 16ft) Proposed pathway Standard size Employee parking space (9ft x 18ft) remove steps thru planter 1 2 3 4 5 9 10 11 14 13 12 15 16 17 19 20-21 EVCS CHARGING STATION FF 371.5ft Proposed patio with low retaining wall 8" Block wall Entry Canopy Parallel size parking space (9ft x 26ft) Employee Parking Proposed pathway RESIDENTIAL BUFF AREA #1 AREA #3 AREA #4 AREA #5 AREA #6 NEW RETAINING WALL WITH 3" GAP BETWEEN PROPERTY LINE AND WALL, FILLED WITH 3/4" GRAVEL COMPACTED 8" x 16" CMU Block (5 1/2 Block) 8" x 16" CMU Block (8 Block) 8" x 16" CMU Block (81/2 Block) Belgium Block Belgium Block Belgium Block Planter 57.07SF Belgium Block Belgium Block Drain 12" Top over 8" CMU(3 Block) No parking Planter 52.04SF AREA #2 Belgium Block Area 70SF AREA #8 AREA #9 FIRE - LANE (20FT WIDE) FIRE - LANE (20FT WIDE) FIRE - LA (20FT W EVSE PARKING SIGN RESERVE PARKING SIGN FOR STAFF NO THROUGH TRAFFIC SIGNS STAFF PARKING SIGN EDGE OF NEW OR REPAIRED ASPHALT SURFACE Wall Box(Locked) EMERGENCY PARKING SIGN AREA #10 Stone pavers 295SF AREA #11 Stone pavers 256.63SF NO THRU TRAFFIC SIGNS ENTRY RIGHT TURN ONLY SIGNS 5 'X 18' Staff Parking Compact size parking space (2) (8ft x 16ft) Standard parking space (9ft x 18ft) RIGHT TURN ONLY SIGNS Belgium Block RESERVE PARKING SIGN FOR STAFF ENTRY NO THRU TRAFFIC SIGNS NO CHANGE TO CURB CUT MT PLEASANT ( RT. 10) 60' ROW 10FT FROM CURB LINE @ 3'6" ABOVE GRADE SIGHT LINE PHOTO 10FT FROM CURB LINE @ 3'6" ABOVE GRADE SIGHT LINE PHOTO AREA #11 23'-5 1/16" EMERGENCY PARKING ADA PARKING SIGN 12" Top over 8" CMU(2.5 Block) New 10" Ballard in 30" x 30" ( 3'0" deep footing) Standard size parking space (9ft x 18ft) 18 29'-0 1 NO PARKING2 FT WIDE "NO PARKING SIGN" PAINTED ON ASPHALT NO PARKING FIRE LANE SIGN MSPR- 4.1 Sheet: REVISION TABLE NUMBER DATE REVISED BY DESCRIPTION Scale: AS NOTED SQUARE CENTER LLC, ARCHITECTURAL DESIGN SERVICES 1581 LINCOLN HWY STE 104, EDISON , NEW JERSEY 08817 973.695.5454 WILLIAM@SQUARECENTERARCH.COM WILLIAM J GENTILE AIA Date: 06/26/2024 Drawn: WJG Job: 20-1203 Of IMMC HEALTH / CACS MINOR SITE PLAN REVIEW 993 PLEASANT VALLEY WAY,
EDISON , NEW JERSEY 08817 973.695.5454 WILLIAM@SQUARECENTERARCH.COM WILLIAM J GENTILE AIA Date: 06/26/2024 Drawn: WJG Job: 20-1203 Of IMMC HEALTH / CACS MINOR SITE PLAN REVIEW 993 PLEASANT VALLEY WAY, WEST ORANGE NJ 07052 NJ LIC. 13878 SIGHT LINE PHOTO ESSAY AT DRIVE WAY EXITS FROM 993 PLEASANT VALLEY WAY SIGHT LINE PHOTO ESSAY 1 24 11 20 WG ADD PAGE
File revisions (1)
- Sep 29, 2026
525a4077bd3b2,254,519 bytes