Supporting Documentation · Mar 20, 2025
2023 06 Drainage Statement
ba02e4150d662e104889401066eb9bdda1b13598babb4fac25c797f1abc67e7cIndexed text · page 22
Show all pagesProject: Proposed Popeyes & Fast Food Restaurant Computed By: DG Job #: 1021-99-025 Checked By: MB Location: West Orange, NJ Date: 7/6/2023 Drainage Area Impervious Impervious Curve HSG C - HSG C - Curve HSG D - HSG D - Curve Avg. Perv. Total Total Area TC (Min.) Area (acre) Area (sf) Number Open Open Number Open Open Number Curve Pervious (acres) (CN) Used Space Area Space Area (CN) Used Space Area Space Area (CN) Used Number Area (acre) (sf) (acre) (sf) (acres) Study Area Site 0.72 31,512 98 0.24 10,603 74 0.08 3,546 80 76 0.32 1.05 4 Total 0.72 31,512 0.24 7,650 0.08 3,546 0.32 1.05 Per County Soil Survey - BouC HSG C Soil Boonton - Urban Land, Boonton substratum complex, 8 to 15 percent slopes Per County Soil Survey - URBONB HSG D Soil Urban Land, Boonton substratum, 0 to 8 percent slopes Runoff Curve Number (CN) Runoff Curve Number (CN) Description (HSG C) (HSG D) Impervious Surface 98 98 Open Space (lawn) (good) 74 80
File revisions (1)
- Sep 29, 2026
ba02e4150d665,567,062 bytes