24 010_ISSUED FOR ZONING
b99d7a5ad2f050c3d8b0b28fba281bf97d5801305675ad4238495e230a79eddcIndexed text
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS SD CO SD SD CO SD CO A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A AA AA A AA A A B B B B B B B B SD SD SD SD EXIT EXIT EXIT EXIT EXITEXIT EXIT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT REFLECTED CEILING LEGEND LIGHT SWITCH LIGHT SWITCH 3 WAY SUSPENDED CEILING GRID AND ACOUSTICAL CEILING TILE. RETURN CEILING MOUNTED LIGHT FIXTURE SUPPLY EXIT EXIT EXIT SIGN W/ EMERGENCY EGRESS LIGHTS EXIT SIGN WITH DIRECTIONAL ARROW NEW SMOKE DETECTOR EMERGENCY PATH OF EGRESS LIGHTS SD CO CARBON MONOXIDE DETECTOR. FIRE DETECTION & NOTIFICATION FIRST FLOOR REFLECTED CEILING PLAN DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-201 OF 24-010 179 SHEET: 1 SCALE: 1/4"=1'-0" FIRST FLOOR PLAN
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS SD CO SD CO SD SD SD CO SD CO SD SD 3 3 EXHAUST FAN EXHAUST FAN EXHAUST FAN EXHAUST FAN EXHAUST FAN FURNACE IN CEILING ABOVE FURNACE IN CEILING ABOVE FURNACE IN CEILING ABOVE EXIT REFLECTED CEILING LEGEND LIGHT SWITCH LIGHT SWITCH 3 WAY SUSPENDED CEILING GRID AND ACOUSTICAL CEILING TILE. RETURN CEILING MOUNTED LIGHT FIXTURE SUPPLY EXIT EXIT EXIT SIGN W/ EMERGENCY EGRESS LIGHTS EXIT SIGN WITH DIRECTIONAL ARROW NEW SMOKE DETECTOR EMERGENCY PATH OF EGRESS LIGHTS SD CO CARBON MONOXIDE DETECTOR. FIRE DETECTION & NOTIFICATION FIRST FLOOR REFLECTED CEILING PLAN DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-202 OF 24-010 1710 SHEET: 2 SCALE: 1/4"=1'-0" SECOND FLOOR PLAN
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS SD CO SD CO SD CO SD CO SD CO SD SD 3 3 EXHAUST FAN EXHAUST FAN EXHAUST FAN EXHAUST FAN EXIT REFLECTED CEILING LEGEND LIGHT SWITCH LIGHT SWITCH 3 WAY SUSPENDED CEILING GRID AND ACOUSTICAL CEILING TILE. RETURN CEILING MOUNTED LIGHT FIXTURE SUPPLY EXIT EXIT EXIT SIGN W/ EMERGENCY EGRESS LIGHTS EXIT SIGN WITH DIRECTIONAL ARROW NEW SMOKE DETECTOR EMERGENCY PATH OF EGRESS LIGHTS SD CO CARBON MONOXIDE DETECTOR. FIRE DETECTION & NOTIFICATION THIRD FLOOR REFLECTED CEILING PLAN DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-203 OF 24-010 17 3 SCALE: 1/4"=1'-0" THIRD FLOOR PLAN 11 SHEET:
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS 10'-0" 10'-0"7'-0" 2ND FLOOR 1ST FLOOR 3RD FLOOR 34'-6" 8'-0" 3'-0" 172-174 ROOF STUCCO FINISH AS SELECTED BY OWNER STUCCO FINISH AS SELECTED BY OWNER STONE VENEER AS SELECTED BY OWNER NEW RAILING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER STONE VENEER AS SELECTED BY OWNER 10'-0" 10'-0" 34'-6" MEAN ELEVATION 2ND FLOOR 1ST FLOOR 3RD FLOOR 8'-0" 3'-0" ROOF STUCCO FINISH AS SELECTED BY OWNER STONE VENEER AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER FRONT AND REAR ELEVATION DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-301 OF 24-010 1712 SHEET: 1 SCALE: 1/4"=1'-0" FRONT ELEVATION 2 SCALE: 1/4"=1'-0" REAR ELEVATION
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS 10'-0" 10'-0"7'-0" 34'-6" MEAN ELEVATION 2ND FLOOR 1ST FLOOR 3RD FLOOR 8'-0" 3'-0" ROOF STUCCO FINISH AS SELECTED BY OWNER STONE VENEER AS SELECTED BY OWNER NEW RAILING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER 10'-0" 10'-0" 34'-6" MEAN ELEVATION 2ND FLOOR 1ST FLOOR 3RD FLOOR 8'-0" 3'-0" ROOF STUCCO FINISH AS SELECTED BY OWNER STONE VENEER AS SELECTED BY OWNER NEW RAILING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER WOOD SIDING AS SELECTED BY OWNER SIDE ELEVATIONS DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-302 OF 24-010 1713 SHEET: 3 SCALE: 1/4"=1'-0" SIDE ELEVATION 4 SCALE: 1/4"=1'-0" SIDE ELEVATION
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 TYPICAL HANDRAIL DETAILA 11" MIN. 12 GAGE RISER AND TREAD 1-1/4" X 1-1/4" X 1/8" CARRIER ANGLE WELDED TO STRINGER 10" CHANNEL WALL BRACKET FASTENED TO WALL. END CAP WELDED CLOSED, FLUSH WITH WALL, TYPICAL. CONCRETE FILLED TREADS 1" RADIUS NOSING SEE STAIR SECTION SEE STAIR SECTION 6" FAN CORNER AND FASTEN WINDOW FLANGE DRIP CAP INSTALL DRIP CAP AT WINDOW HEAD DO NOT APPLY SEALANT ACROSS SILL FLEXWRAP, STRAIGHTFLASH AND WEATHERIZATION SEALANT BY DUPONT, OR EQUAL PRODUCTS: TAPE DIAGONAL WRB SEAMS INSTALL HEAD FLASHING OVER LAPPING JAMB FLASHING. FOLD DOWN FLAP OF WRB OVER HEAD FLASHING. TAPE DIAGONAL WRB SEAMS. TAPE WRB TO FACE OF DRIP CAP JAMB FLASHING OVER LAPS FLEXWRAP SILL FLASHING COMPLETELY RAISED FLAP OF WRB RAISED FLAP OF WRB INSTALL JAMB FLASHING OVER WINDOW FLANGE AND OVER LAPPING FLEXWRAP AT SILL. FLASHING INSTALL WINDOW ON TOP OF SEALANT AND FLEXWRAP. FOLLOW MFR'S WRITTEN INSTALLATION INSTRUCTIONS SEALANT ON 3 SIDES APPLY BEAD OF SEALANT ON JAMBS AND HEAD. FLEXWRAP RUN FLEXWRAP 6" UP JAMB CUT FLEXWRAP 12" LONGER THAN ROUGH OPENING WIDTH. ALIGN WITH INSIDE EDGE OF SILL AND FOLD DOWN MIN 3" ONTO FACE OF WALL. FAN CORNERS AND FASTEN CORNERS WITH MFR'S REQUIRED FASTENERS FLEXWRAPWEATHER RESISTANT BARRIER (WRB) WRAP WRB AROUND ROUGH OPENING AT JAMBS AND SILL, TRIM AND SECURE TO INSIDE OF WALL. CUT THE BARRIER ON A DIAGONAL. RAISE THE TOP FLAP OF THE BARRIER UP AND TAPE TO THE EXTERIOR WRB SURFACE ABOVE. WEATHER RESISTANT BARRIER (WRB) 1. TEMPERED GLASS TO BE INSTALLED WHERE REQUIRED BY CODE, NOT LIMITED TO: 1.1. ANY WINDOW OR SIDELIGHT WITHIN 24 INCHES HORIZONTALLY OF A DOOR MUST BE TEMPERED. 1.2. ANY WINDOW OR SASH THAT IS 9 SQUARE FEET OR MORE AND IS 18 INCHES OR LESS FROM A FLOOR MUST BE TEMPERED. 1.3. ANY WINDOW WITHIN A TUB OR SHOWER AREA THAT IS LESS THAN 60 INCHES FROM THE FLOOR OF THE TUB MUST BE TEMPERED. 1.4. ANY WINDOW ON A STAIRCASE LANDING OR WITHIN 60 INCHES A STAIRCASE TREAD MUST BE TEMPERED. ALL FIRE STOPPING PRODUCT NUMBERS REFER TO 3M FIRE PROTECTION PRODUCTS, OR EQUAL. CONTRACTOR SHALL SUBMIT MFR'S PRODUCT LITERATURE TO ARCHITECT FOR REVIEW. THROUGH PENETRATION FIRESTOPPING APPLICATION SHALL BE BY A CONTRACTOR CERTIFIED BY THE MANUFACTURER TO PROPERLY PREPARE AND APPLY THEIR PRODUCTS ACCORDING TO THEIR WRITTEN INSTRUCTIONS. MANUFACTURER'S REPRESENTATIVE SHALL REVIEW THE
APPLICATION SHALL BE BY A CONTRACTOR CERTIFIED BY THE MANUFACTURER TO PROPERLY PREPARE AND APPLY THEIR PRODUCTS ACCORDING TO THEIR WRITTEN INSTRUCTIONS. MANUFACTURER'S REPRESENTATIVE SHALL REVIEW THE PROJECT CONDITIONS AND REQUIREMENTS AND SELECT THE MOST APPROPRIATE PRODUCT TO BEST ACHIEVE THE REQUIRED ONE HOUR FIRE PROTECTION. PRODUCT LITERATURE SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO APPLICATION OF THE FIRE RESISTIVE MATERIAL. WALL ASSEMBLY - GYPSUM BOARD AND METAL STUD 1 METALLIC PIPE OR CONDUIT2 CAULK CP 25WB3 W-L-1001 1, 2, 3 AND 4 HOUR FIRE RATING SECTION A-A 1 3 2 A A APRON FLASHING STEP FLASHING BACKER FLASHING OPTIONAL HEMMED EDGES (SHOP FORMED FLASHING WITH SOLDERED OR SEALED CORNERS) NOTES: 1. FLASHING DIMENSIONS WILL VARY ACCORDING TO LOCAL WEATHER CONDITIONS, SIZE, LOCATION, SLOPE OF ROOF, AND TRIBUTARY WATER AREA. 2. A SADDLE FLASHING WILL BE ALLOWED FOR PENETRATIONS LESS THAN 30" IN WIDTH. EXTEND A MINIMUM OF 6" OR TO TOP OF CURB AND 14" UP ROOF SLOPE. 3. A CRICKET FLASHING IS RECOMMENDED FOR PENETRATIONS EQUAL TO OR GREATER THAN 30" IN WIDTH TO PROMOTE POSITIVE RUNOFF. 4. ONE LAYER OF NO. 30 ASPHALT-SATURATED FELT COMPLYING WITH ASTM D-226 TYPE II (ASTM D4869 TYPEIV), OR APPROVED EQUAL AS A MINIMUM UNDERLAYMENT ON ALL TILE ROOF APPLICATIONS. OTHER UNDERLAYMENTS AS APPROVED BY LOCAL BUILDING OFFICIALS WILL BE ALLOWED. 5. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE TO ALLOW FOR REASONABLE TOLERANCES DUE TO FIELD CONDITIONS. 6. MALEABLE METAL OPTIONAL FOR PROFILED TILE. APRON FLASHING STEP FLASHING BACKER FLASHING OPTIONAL HEMMED EDGES (SHOP FORMED FLASHING WITH SOLDERED OR SEALED CORNERS) NOTES: 1. FLASHING DIMENSIONS WILL VARY ACCORDING TO LOCAL WEATHER CONDITIONS, SIZE, LOCATION, SLOPE OF ROOF, AND TRIBUTARY WATER AREA. 2. A SADDLE FLASHING WILL BE ALLOWED FOR PENETRATIONS LESS THAN 30" IN WIDTH. EXTEND A MINIMUM OF 6" OR TO TOP OF CURB AND 14" UP ROOF SLOPE. 3. A CRICKET FLASHING IS RECOMMENDED FOR PENETRATIONS EQUAL TO OR GREATER THAN 30" IN WIDTH TO PROMOTE POSITIVE RUNOFF. 4. ONE LAYER OF NO. 30 ASPHALT-SATURATED FELT COMPLYING WITH ASTM D-226 TYPE II (ASTM D4869 TYPEIV), OR APPROVED EQUAL AS A MINIMUM UNDERLAYMENT ON ALL TILE ROOF APPLICATIONS. OTHER UNDERLAYMENTS AS APPROVED BY LOCAL BUILDING OFFICIALS WILL BE ALLOWED. 5. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE
S A MINIMUM UNDERLAYMENT ON ALL TILE ROOF APPLICATIONS. OTHER UNDERLAYMENTS AS APPROVED BY LOCAL BUILDING OFFICIALS WILL BE ALLOWED. 5. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE TO ALLOW FOR REASONABLE TOLERANCES DUE TO FIELD CONDITIONS. 6. MALEABLE METAL OPTIONAL FOR PROFILED TILE. APRON FLASHING STEP FLASHING BACKER FLASHING OPTIONAL HEMMED EDGES (SHOP FORMED FLASHING WITH SOLDERED OR SEALED CORNERS) NOTES: 1. FLASHING DIMENSIONS WILL VARY ACCORDING TO LOCAL WEATHER CONDITIONS, SIZE, LOCATION, SLOPE OF ROOF, AND TRIBUTARY WATER AREA. 2. A SADDLE FLASHING WILL BE ALLOWED FOR PENETRATIONS LESS THAN 30" IN WIDTH. EXTEND A MINIMUM OF 6" OR TO TOP OF CURB AND 14" UP ROOF SLOPE. 3. A CRICKET FLASHING IS RECOMMENDED FOR PENETRATIONS EQUAL TO OR GREATER THAN 30" IN WIDTH TO PROMOTE POSITIVE RUNOFF. 4. ONE LAYER OF NO. 30 ASPHALT-SATURATED FELT COMPLYING WITH ASTM D-226 TYPE II (ASTM D4869 TYPEIV), OR APPROVED EQUAL AS A MINIMUM UNDERLAYMENT ON ALL TILE ROOF APPLICATIONS. OTHER UNDERLAYMENTS AS APPROVED BY LOCAL BUILDING OFFICIALS WILL BE ALLOWED. 5. DIMENSIONS SHOWN ARE MINIMUMS AND ARE INTENDED TO BE APPROXIMATE TO ALLOW FOR REASONABLE TOLERANCES DUE TO FIELD CONDITIONS. 6. MALEABLE METAL OPTIONAL FOR PROFILED TILE. STUCCO COLOR SHALL BE SELECTED BY ARCHITECT FROM FULL RANGE OF MANUFACTURER'S COLORS. CONTROL JOINTS SHALL NOT EXCEED 18 FT IN EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2.5 TO 1 IN ANY SINGLE STUCCO PANEL. PORTLAND CEMENT SHALL CONTAIN FIBER CONTENT. 1/8" FINISH COAT ON 3/8" SCRATCH COAT ON 3/8" BROWN COAT ON GALVANIZED EXPANDED METAL LATH ON WATER RESISTIVE BARRIER ON 7/8" GALVANIZED 16 GAGE METAL FURRING PORTLAND CEMENT STUCCO NOTES STUCCO IS A 3 COAT SYSTEM CONSISTING OF: INSIDE AND OUTSIDE CORNER DETAILS ABUTTING ANOTHER MATERIAL DETAIL EXPANSION JOINT DETAIL WEEP SCREED DETAIL AT TOP OF FOUNDATION WALL APPROVED PVC ACCESSORIES MAY BE SUBSTITUTED FOR GALVANIZED STEEL ACCESSORIES UPON REVIEW BY ARCHITECT. MATCH EXISTING STUCCO FINISH TEXTURE AND COLOR. INSTALLATION SHALL COMPLY WITH: ASTM C 926-06 SPECIFICATION FOR APPLICATION OF PORTLAND CEMENT-BASED PLASTERASTM C 1063-08 STANDARD SPECIFICATION FOR INSTALLATION OF LATHING AND FURRING TO RECEIVE INTERIOR AND EXTERIOR PORTLAND CEMENT-BASED PLASTER WIRE TIE JOINT FLANGES TO LATH. DO NOT NAIL TO SUBSTRATE GALVANIZED STEEL EXPANSION JOINT. 7/8" THCK 3 COAT CEMENT
OF LATHING AND FURRING TO RECEIVE INTERIOR AND EXTERIOR PORTLAND CEMENT-BASED PLASTER WIRE TIE JOINT FLANGES TO LATH. DO NOT NAIL TO SUBSTRATE GALVANIZED STEEL EXPANSION JOINT. 7/8" THCK 3 COAT CEMENT STUCCO HEAD, JAMB AND SILL 7/8" THCK 3 COAT CEMENT STUCCO WINDOW FRAME OR TRIM TROWEL CUT BROWN AND FINISH COATS TO FORM 3/8" WIDE GROOVE FOR SEALANT BOND BREAKER AND SEALANT CAULK JOINT ALTERNATE - 2 GALVANIZED CASING BEADS. CAULK JOINT GALVANIZED STEEL INSIDE CORNER JOINT. 7/8" THCK 3 COAT CEMENT STUCCO GALVANIZED CORNER BEAD DETAILS DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-401 OF 24-010 1714 SHEET: 3 NO SCALE (DOORS SIMILIAR) WINDOW FLASHING DETAILS 1 NOT TO SCALE STAIR RISER DETAIL
REVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 48" H STANDPIPE 2"W 3" VTR FIRST FLOOR TO WASTE LINE 1 1/2"W2"W UTILITY SINK 3"W TOILET 1 1/2"W LAV SINK 3"W TOILET 1 1/2"W LAV 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 3"W TOILET 1 1/2"W LAV TOILET LAV 3"W 1 1/2"W SECOND FLOOR THIRD FLOOR ROOF 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W 1 1/2"W LAV TOILET 2"W 3"W 3" W 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W 1 1/2"W LAV TOILET 2"W3"W 3" W 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2" V 1 1/2"W LAV TOILET 2"W3"W 3" W EFFICIENCY 2-BEDROOM 2-BEDROOM 1 1/2" V 1 1/2" V 1 1/2" V 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W EFFICIENCY 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W 1-BEDROOM 1 1/2" V 48" H STANDPIPE 2"W 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W EFFICIENCY 48" H STANDPIPE 2"W 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W 1-BEDROOM 3" VTR 3" VTR3" VTR 3" VTR 3" VTR 1 1/2" V 1 1/2" V 1 1/2" V 1 1/2" V TENANT 1 TENANT 2 SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAMSEE ISLAND VENT DIAGRAM 2ND FLOOR 1ST FLOOR 3RD FLOOR ROOF G CELLAR G G G G G G G TENANT # 1 TENANT # 2 APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 G FURNACE IN ATTIC (66 MBH) FURNACE IN ATTIC (66 MBH) FURNACE IN ATTIC (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) TENANT #1 (120 MBH) TENANT #2 (120 MBH) APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF 5' OF 1" NOTE: WATER HEATERS, STOVES, AND DRYERS ARE ARE ELECTRIC. NOTE: WATER HEATERS ARE ELECTRIC. NOTE: WATER HEATERS, STOVES, AND DRYERS ARE ARE ELECTRIC. 5' OF 1" 48' OF 1" 62' OF 1" 25' OF 1" 25' OF 1" 25' OF 1" 20' OF 1" 40' OF 1" 40' OF 1" 30' OF 1" 30' OF 1" 30' OF 1" 30' OF 1" 17' OF 1" 22' OF 1" 50' OF 1" 40' OF 1" 120 MBTU FURNACE (TENANT 1) 120 MBTU FURNACE (TENANT 2) 66 MBTU FURNACE (APT 1) 66 MBTU FURNACE (APT 2) 66 MBTU FURNACE (APT 3) 66 MBTU FURNACE (APT 4) 66 MBTU FURNACE (APT 5) 66 MBTU FURNACE (APT 6) 66 MBTU FURNACE (APT 7) 702 MBTU