Supporting Documentation · Feb 5, 2025
24 010_ISSUED FOR ZONING
b99d7a5ad2f050c3d8b0b28fba281bf97d5801305675ad4238495e230a79eddcIndexed text · page 15
Show all pagesREVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 48" H STANDPIPE 2"W 3" VTR FIRST FLOOR TO WASTE LINE 1 1/2"W2"W UTILITY SINK 3"W TOILET 1 1/2"W LAV SINK 3"W TOILET 1 1/2"W LAV 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 1 1/2"W SINK 3"W TOILET 1 1/2"W LAV TOILET LAV 3"W 1 1/2"W SECOND FLOOR THIRD FLOOR ROOF 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W 1 1/2"W LAV TOILET 2"W 3"W 3" W 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W 1 1/2"W LAV TOILET 2"W3"W 3" W 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2" V 1 1/2"W LAV TOILET 2"W3"W 3" W EFFICIENCY 2-BEDROOM 2-BEDROOM 1 1/2" V 1 1/2" V 1 1/2" V 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W EFFICIENCY 48" H STANDPIPE 2"W1 1/2" W D/WKITCHEN SINK 1 1/2"W LAV TOILET 2"W3"W 3" W 1-BEDROOM 1 1/2" V 48" H STANDPIPE 2"W 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W EFFICIENCY 48" H STANDPIPE 2"W 1 1/2" W D/W KITCHEN SINK 1 1/2"W LAV TOILET 2"W 3"W 3" W 1-BEDROOM 3" VTR 3" VTR3" VTR 3" VTR 3" VTR 1 1/2" V 1 1/2" V 1 1/2" V 1 1/2" V TENANT 1 TENANT 2 SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAM SEE ISLAND VENT DIAGRAMSEE ISLAND VENT DIAGRAM 2ND FLOOR 1ST FLOOR 3RD FLOOR ROOF G CELLAR G G G G G G G TENANT # 1 TENANT # 2 APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 G FURNACE IN ATTIC (66 MBH) FURNACE IN ATTIC (66 MBH) FURNACE IN ATTIC (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) FURNACE (66 MBH) TENANT #1 (120 MBH) TENANT #2 (120 MBH) APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF CONDENSER ON ROOF 5' OF 1" NOTE: WATER HEATERS, STOVES, AND DRYERS ARE ARE ELECTRIC. NOTE: WATER HEATERS ARE ELECTRIC. NOTE: WATER HEATERS, STOVES, AND DRYERS ARE ARE ELECTRIC. 5' OF 1" 48' OF 1" 62' OF 1" 25' OF 1" 25' OF 1" 25' OF 1" 20' OF 1" 40' OF 1" 40' OF 1" 30' OF 1" 30' OF 1" 30' OF 1" 30' OF 1" 17' OF 1" 22' OF 1" 50' OF 1" 40' OF 1" 120 MBTU FURNACE (TENANT 1) 120 MBTU FURNACE (TENANT 2) 66 MBTU FURNACE (APT 1) 66 MBTU FURNACE (APT 2) 66 MBTU FURNACE (APT 3) 66 MBTU FURNACE (APT 4) 66 MBTU FURNACE (APT 5) 66 MBTU FURNACE (APT 6) 66 MBTU FURNACE (APT 7) 702 MBTU
MBTU FURNACE (TENANT 2) 66 MBTU FURNACE (APT 1) 66 MBTU FURNACE (APT 2) 66 MBTU FURNACE (APT 3) 66 MBTU FURNACE (APT 4) 66 MBTU FURNACE (APT 5) 66 MBTU FURNACE (APT 6) 66 MBTU FURNACE (APT 7) 702 MBTU TOTAL APT # 4 APT # 3 APT # 2 APT # 1 COMMON AREA APT # 5 APT # 6 APT # 7 TENANT #1 TENANT #2 100 100 100 100 100 100 100 100 200 200#6 COPPER GROUND TO WATER MAIN #4 COPPER GROUND TO DRIVEN GROUND ROD #4 COPPER GROUND TO MIN 20'-0" LENGTH OF FOOTING RE-BAR ELECTRICAL PANEL E.P. 200 AMP SERVICE 2" CONDUIT (2) # 3/0 AND (1) # 3/0 NEUTRAL Foot Vent Below Floor Slope at 1/4"per foot Vent Up in Wall Cleanout High Water Level- Rim of Sink or the counter top Bring Vent Up as Hight as Possible90 Deg Fitting Vent Waste SINK Cleanout "Y" Fitting Waste Below Floor Cleanout ISLAND VENT DETAIL SINGLE LEVER HOT AND COLD WATER SHUTOFF VALVE PREFABRICATED WASHER VALVE BOX RECESSED IN WALL 2" DIA STANDPIPE WITHIN WALL WITH DEEP SEAL TRAP VENT PIPE CLEAN OUT WITH THREADED BRASS PLUG AND STAINLESS STEEL COVER PLATE ON FACE OF WALL FINISH WASTE STACK FLOOR HW CW DEEP SEAL TRAP WITH AUTOMATIC TRAP PRIMER DRAIN PAN AUTO. TRAP PRIMER METALLIC DRAIN PANS SHALL BE 24 GAGE MINIMUM. NON-METALLIC DRAIN PANS SHALL BE .0625" MINIMUM. PANS SHALL BE NOT LESS THAN 1 1/2" DEEP AND SHALL BE OF SUFFICIENT SIZE TO HOLD THE APPLIANCE WITHOUT INTERFERING WITH ANY REQUIRED ACCESS. HEATING ELEMENT TYPICAL COMBINATION TEMPERATURE AND PRESSURE RELIEF OF TANK VACUUM RELIEF VALVE SHALL BE INSTALLED ON THE STORAGE TANK. AT AN ELEVATION ABOVE THE FIXTURE OUTLETS IN THE SYSTEM A WATER STORAGE TANK OR INDIRECT WATER HEATER IS LOCATED N.S.P.C. 10.16.7 REQUIRES: WHERE A HOT FLOOR 4" HOUSEKEEPING PAD HOSE BIBB SEISMIC STRAP DIP TUBE INSIDE UNION, TYPICAL GATE VALVE, TYPICAL COLD WATER VACUUM RELIEF VALVE HOT WATER SUPPLY VALVE DRAIN AQUASTAT TYPICAL PLUMBING RISER DIAGRAM GAS RISER DIAGRAM ELECTRICAL RISER DIAGRAM DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without
in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-402 OF 24-010 17 1 NOT TO SCALE PLUMBING RISER DIAGRAM- SCHEMATIC 15 SHEET: 2 NOT TO SCALE GAS RISER DIAGRAM- SCHEMATIC 3 NOT TO SCALE ELECTRICAL RISER DIAGRAM- SCHEMATIC E NOT TO SCALE ISLAND VENT DIAGRAM L NOT TO SCALE LAUNDRY PAN DETAIL W NOT TO SCALE ELECTRICA WATER HEATER DETAIL
File revisions (1)
- Sep 29, 2026
b99d7a5ad2f03,493,010 bytes