Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Nov 10, 2024

2025 01 14 West Essex Highlands Development Building D Slope Stability Study

Preserved file SHA-25641e0e373f7d9335c86c890d31766312e59b4f9e9c0658a80f50902bd7ecf304b

Indexed text · page 11

Show all pages
Page 11

Memorandum 300 Kimball Drive To: Parsippany, NJ 07054 T: 973.560.4900 F: 973.560.4901 Mark Hoffman / Garden Homes From: Mark K. Seel / Langan Ronald D. Boyer / Langan Info: Adam Yoda / Langan John Cote / Langan Michael Vitello / Langan Date: 14 January 2025 Re: Global Slope Stability Study for Building D West Essex Highlands Project West Orange, New Jersey Langan Project No.: 101049801 Ronald D. Boyer, P.E. Professional Engineer NJ Lic. No. 24GE04200300 This memorandum summarizes the subsurface investigation and global slope stability evaluation performed by Langan Engineering and Environmental Services, LLC (Langan) for the eastern portion of the proposed West Essex Highlands development site located in West Orange, New Jersey. The following sections provide a description of existing site conditions, proposed development, subsurface investigation and conditions, our global slope stability analysis and our evaluation regarding slope stability with respect to the associated building construction. EXISTING CONDITIONS AND PROPOSED CONSTRUCTION The subject project site is located on Lot 32, Block 179, and is bounded by Avon Drive and Howell Drive and residential properties to the north, and residential developments to the south, east and west. The study area for the global slope stability analysis is the easternmost portion of the site bounded by Rosemont Terrace and Mayfair Drive to the east. The study area is heavily wooded and surface grades slope downward from west to east. There is a 25-foot-wide utility easement that bisects the subject area running in the north-south direction. Site surface grades generally range from approximately elevation (el) 616 to el 450. Typically, the slope in the subject area ranges from 2 Horizontal (H): 1 Vertical (V) or approximately 26 degrees from horizontal at its steepest to approximately 6H:1V or approximately 10 degrees from horizontal east of the utility easement. The proposed residential development will consist of the construction of new 4-story structures over structured parking. Based on available site drawings prepared by Anderson Consulting Services, LLC. (ACS), the closest building to the subject slope is proposed Building D, which is to be located at the top of the slope within the study area approximately 700 ft west of the eastern property line. We understand that no site improvements are proposed

Page 11

s proposed Building D, which is to be located at the top of the slope within the study area approximately 700 ft west of the eastern property line. We understand that no site improvements are proposed in the wooded subject area located approximately 20 ft east of the proposed eastern building line of Building D.

File revisions (1)