POA-2 2024-05-12 HydroCad - Proposed POA 2B-1 NOAA 24-hr D 2-Year Rainfall=3.44" Prepared by Anderson Consulting Services HydroCAD® 10.20-5c s/n 06666 © 2023 HydroCAD Software Solutions LLC Printed 10/25/2024 Page 56 Summary for Subcatchment 54S: Basin 9 - Perv Runoff = 0.33 cfs @ 12.15 hrs, Volume= Routed to Pond 42P : Basin 9 1,079 cf, Depth= 1.45" Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-80.00 hrs, dt= 0.04 hrs NOAA 24-hr D 2-Year Rainfall=3.44" Area (sf) 2,537 6,379 8,916 8,916 CN 74 80 78 Description >75% Grass cover, Good, HSG C >75% Grass cover, Good, HSG D Weighted Average 100.00% Pervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 7.2 100 0.1000 0.23 Sheet Flow, Sheet Flow (A-B) Grass: Dense n= 0.240 P2= 3.47" 0.2 40 0.0750 4.41 Shallow Concentrated Flow, SCF (B-C) Unpaved Kv= 16.1 fps 7.4 140 Total Sheet Flow (A-B) Subcatchment 54S: Basin 9 - Perv SCF (B-C)