Supporting Documentation · Nov 10, 2024
complete drainage report rev 9
0e69db2cf67e6dbdea5b757902b09270a6560667c8ebecd3dc74327e4422cf0dIndexed text · page 865
Show all pagesVAULT WIDTH VAULT LENGTH INLET SHAPING (NOT BY CONTECH) VAULT LENGTH CLEAN OUT A C B VAULT LENGTH VAULT LENGTH B C VAULT LENGTH A TREE GRATE CURB INLET OPENING CURB (NOT BY CONTECH) SDR 35 OUTLET COUPLING CAST INTO PRECAST VAULT WALL (OUTLET PIPE LOCATION MAY VARY) PLAN VIEW PLAN VIEW ENERGY DISSIPATION ROCKS GALVANIZED ANGLE NOSING CLEAN OUT FRAME AND COVER CAST INTO TOP SLAB STREET 2"Ø IRRIGATION PORT, TYP. 3 PLACES 6" UNDERDRAIN STONE LAYER, TYP. PROVIDED BY CONTECH 3'-4" (3.33') INV. TO TOP TOP SLAB 3" MULCH LAYER, TYP. PROVIDED BY CONTECH 18" FILTERRA MEDIA, TYP. PROVIDED BY CONTECH 6"Ø UNDERDRAIN FLOWKIT PROVIDED BY CONTECH SECTION B-B SECTION A-A SECTION C-C FT-HC LONG SIDE INLET CONFIGURATION DESIGNATION AVAILABILITY FT0604-HC ALL DE, MD, NJ, PA, VA, WV ONLY N/A DE, MD, NJ, PA, VA, WV FT078045-HC FT0804-HC 3'-4" (3.33') INV. TO TOP CURB AND GUTTER (NOT BY CONTECH) SEE FILTERRA STANDARD OFFLINE CURB INLET DETAIL SHEET TREE FRAME AND GRATE CAST INTO TOP SLAB 3'-4" (3.33') INV. TO TOP I:\STORMWATER\COMMOPS\54 FILTERRA\40 STANDARD DRAWINGS\FT-HC - FILTERRA HC (NEW JERSEY ONLY)\FT-HC - FILTERRA OFFLINE CONFIG DTL.DWG 9/8/2022 11:23 AM PLAN VIEW MEDIA BAY SIZE VAULT SIZE (L x W) OUTLET PIPE DIA TREE GRATE QTY & SIZE DESIGNATION AVAILABILITY 6x4 6x4 6" SDR 35 (1) 3' x 3' FT0406-HC 6" SDR 35 (1) 3' x 3' ALL N/A DE, MD, NJ, PA, VA, WV DE, MD, NJ, PA, VA, WV ONLY 7.83 x 4.5 8x4 7.83 x 4.5 FT-HC SQUARE INLET CONFIGURATION FT-HC SHORT SIDE INLET CONFIGURATION FT0408-HC 8x4 6" SDR 35 (1) 3' x 3' FT045078-HC TREE GRATE QTY & SIZE TREE GRATE QTY & SIZE VAULT SIZE (W x L) OUTLET PIPE DIA 4x6 4x6 6" SDR 35 (1) 3' x 3' FT0404-HC ALL 4x4 4x4 6" SDR 35 (1) 3' x 3' 6" SDR 35 (1) 3' x 3' FT0606-HC ALL 6x6 6x6 6" SDR 35 (1) 3' x 3' 4x8 4x8 DESIGNATION AVAILABILITY MEDIA BAY SIZE N/A = NOT AVAILABLE 4.5 x 7.83 4.5 x 7.83 6" SDR 35 (1) 3' x 3' FT0806-HC ALL 8x6 8x6 6" SDR 35 (1) 4' x 4' FT0608-HC ALL 6x8 6x8 6" SDR 35 (1) 4' x 4' FT1006-HC ALL 10 x 6 10 x 6 6" SDR 35 (1) 4' x 4' FT0610-HC ALL 6 x 10 6 x 10 6" SDR 35 (1) 4' x 4' FT1206-HC ALL 12 x 6 12 x 6 6" SDR 35 (2) 4' x 4' FT0612-HC ALL 6 x 12 6 x 12 6" SDR 35 (2) 4' x 4' FT1307-HC ALL 13 x 7 13 x 7 6" SDR 35 (2) 4' x 4' FT0713-HC ALL 7 x 13 7 x 13 6" SDR 35 (2) 4' x
x 6 12 x 6 6" SDR 35 (2) 4' x 4' FT0612-HC ALL 6 x 12 6 x 12 6" SDR 35 (2) 4' x 4' FT1307-HC ALL 13 x 7 13 x 7 6" SDR 35 (2) 4' x 4' FT0713-HC ALL 7 x 13 7 x 13 6" SDR 35 (2) 4' x 4' FT1408-HC CALL CONTECH 14 x 8 14 x 8 6" SDR 35 (2) 4' x 4' N/A = NOT AVAILABLE FT1509-HC CALL CONTECH 15 x 9 15 x 9 6" SDR 35 (2) 4' x 4' FT1608-HC CALL CONTECH 16 x 8 16 x 8 6" SDR 35 (2) 4' x 4' FT1808-HC CALL CONTECH 18 x 8 18 x 8 6" SDR 35 (2) 4' x 4' FT2008-HC CALL CONTECH 20 x 8 20 x 8 6" SDR 35 (3) 4' x 4' FT2208-HC CALL CONTECH 22 x 8 22 x 8 6" SDR 35 (3) 4' x 4' The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC or one of its affiliated companies ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. N/A = NOT AVAILABLE www.ContechES.com THIS PRODUCT MAY BE PROTECTED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 6,277,274; 6,569,321; 7,625,485; 7,425,261; 7,833,412; RELATED FOREIGN PATENTS. INTERNAL PIPE CONFIGURATION MAY VARY DEPENDING UPON OUTLET LOCATION. VAULT OUTLET SIZE PIPE (W x L) DIA MEDIA BAY SIZE 800-338-1122 513-645-7000 513-645-7993 FAX FILTERRA HC OFFLINE (FT-HC) CONFIGURATION DETAIL
File revisions (1)
- Sep 29, 2026
0e69db2cf67e45,040,158 bytes