Page 938

CASCADE SEPARATOR DESIGN NOTES 180° THE STANDARD CS-4 CONFIGURATION IS SHOWN. A A FLOW FLOW SITE SPECIFIC DATA REQUIREMENTS STRUCTURE ID WATER QUALITY FLOW RATE (cfs [L/s]) TOP SLAB ACCESS (SEE FRAME AND COVER DETAIL) PEAK FLOW RATE (cfs [L/s]) RETURN PERIOD OF PEAK FLOW (yrs) PLAN VIEW B-B ® RIM ELEVATION www.ContechES.com NOT TO SCALE PIPE DATA: INVERT MATERIAL DIAMETER INLET PIPE 1 INLET PIPE 2 OUTLET PIPE CONTRACTOR TO GROUT TO FINISHED GRADE NOTES / SPECIAL REQUIREMENTS: GRADE RINGS/RISERS FRAME AND COVER (DIAMETER VARIES) NOT TO SCALE INLET PIPE B OUTLET PIPE PERMANENT POOL ELEVATION (4'-0" [1219]) B VARIES TOP OF CENTER CHAMBER (EXTENSIONS AVAILABLE AS REQUIRED) 2'-3" [686] I:\COMMON\CAD\TREATMENT\21 CASCADE\40 STANDARD DRAWINGS\NJ SPECIFICATION DTLS\DWG\IN PROCESS\CS-4-NJ-DTL.DWG 6/26/2023 2:17 PM 48" [1219] I.D. MANHOLE STRUCTURE FIBERGLASS OR POLYPROPYLENE INTERNAL COMPONENTS SOLIDS STORAGE SUMP ELEVATION A-A NOT TO SCALE GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. FOR SITE SPECIFIC DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com 3. CASCADE SEPARATOR WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 4. CASCADE SEPARATOR STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 2' [610], AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. 5. CASCADE SEPARATOR STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C478 AND AASHTO LOAD FACTOR DESIGN METHOD. 6. ALTERNATE UNITS ARE SHOWN IN MILLIMETERS [mm ]. INSTALLATION NOTES A. ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CASCADE SEPARATOR MANHOLE STRUCTURE. C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET AND OUTLET PIPE(S). MATCH PIPE INVERTS WITH ELEVATIONS

Page 938

C. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET AND OUTLET PIPE(S). MATCH PIPE INVERTS WITH ELEVATIONS SHOWN. ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. E. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO ASSURE UNIT IS WATER TIGHT, HOLDING WATER TO FLOWLINE INVERT MINIMUM. IT IS SUGGESTED THAT ALL JOINTS BELOW PIPE INVERTS ARE GROUTED. www.contechES.com 9100 Centre Pointe Dr., Suite 400, West Chester, OH 45069 800-338-1122 513-645-7000 513-645-7993 FAX CS-4 CASCADE SEPARATOR STANDARD DETAIL

File revisions (1)