SETON HALL PR H#PARATORY SCHOOL H H#ALTH AN FITNESS C INTER SCHEDULE OF REVISIONS DRAWN] CHK. DESCRIPTION OF CHANGES ee REV. DATE PRELIMINARY AN ) FINAL SITE PPROVAL ZONING ANALYSIS TABLE ZONE: R-1, SINGLE FAMILY RESIDENTIAL DISTRICT PROPOSED USE: PRIVATE HIGH SCHOOL REFERENCE: TOWNSHIP OF WEST ORANGE MUNICIPAL CODE, LATEST EDITION PER MUNICIPAL CODE EXISTING PROPOSED PERMITTED USES ONE FAMILY, DETACHED DWELLING; WATER RESERVOIR, WELL TOWER, FILTER BED; FEDERAL, STATE, COUNTY OR TOWNSHIP BUILDING; GOLF COURSE AND GOLF CLUB HOUSE; FARM, NURSERY, GREENHOUSE AND SIMILAR USES; HOSPITAL. PRIVATE SCHOOL PRIVATE SCHOOL PERMITTED CONDITIONAL USES COMMERCIAL RECREATION; PUBLIC SCHOOL; PRIVATE SCHOOL; LIBRARY; MUSEUM; PARK OR PLAYGROUND; PUBLIC UTILITY BUILDING OR STRUCTURE; TELEPHONE EXCHANGE; PRIVATE CLUB, OTHER THAN A GOLF CLUB; HOUSE OF WORSHIP PRIVATE SCHOOL PRIVATE SCHOOL MINIMUM LOT AREA 80,000 SQUARE FEET 44.50 ACRES (1,938,496 SF) 44.50 ACRES (1,938,496 SF) MINIMUM LOT WIDTH 700 PROSPECT AVENUE ZONE: R-1 SINGLE FAMILY RESIDENTIAL DISTRICT BLOCK: 82.01 LOT 1 TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW AbReET REFERENCE: 250° 50 2021 MICROSOFT IMAGERY eae sya STTE LOCATION MAP 1" = 500' SCALE: 1"=500" PARKING CALCULATION 150 FT 1,160.9 FT 1,160.9 FT MINIMUM LOT DEPTH NO REQUIREMENT N/A N/A MAXIMUM LOT COVERAGE — ans re SETBACKS MIN, FRONT FULL SITE 194.9 FT (EXISTING FULL SITE FIELD HOUSE TO 194.9 FT (EXISTING FIELD SROEPUCT ATE a5 EE HOUSE TO PROSPECT AVE) EX, STORAGE BUILDING SSO 391.9 FT (MOUNTAIN DRIVE) | 301 grr (MOUNTAIN DRIVE) MIN. SIDE FULL SITE 118.5 FT (EXISTING FIELD HOUSE TO FULL SITE SOUTHERN LINE) 118.5 FT (EXISTING FIELD | 5675 Fr cexiaTING HOUSE TO SOUTHERN LINE) oO eS 767.3 FT (EXISTING FIELD ROR LINE 25 FT/25 FT HOUSE TO NORTH LINE) EX, STORAGE BUILDING New ess 978.1 FT (TO SOUTHERN LINE) aarp 819.6 FT (TO NORTH LINE) SOUTHERN LINES 808.3 FT (TO NORTH LINE) MIN. REAR FULL SITE FULL SITE 138.1 FT (NEW 138.1 FT (EXISTING STORAGE | -rrwecs BUILDING) — BUILDING) EX, STORAGE BUILDING New ess 138-1 FT “138.1 FT CONDITIONAL USE SETBACK FULL SITE* FULL SITE* aU SHE 125 FT 118.5 FT (EXISTING FIELD | 128-5 FT (EXISTING HOUSE TO SOUTHERN LINE) FIELD HOUSE TO SOUTHERN LINE) BUILDING REQUIREMENTS MAXIMUM BUILDING HEIGHT (STORIES/FT) 2-1/2 STORY/35 FT < 2-1/2 STORY/35 FT < 2-1/2 STORY/35 FT EXISTING PARKING

Page 1

TING HOUSE TO SOUTHERN LINE) FIELD HOUSE TO SOUTHERN LINE) BUILDING REQUIREMENTS MAXIMUM BUILDING HEIGHT (STORIES/FT) 2-1/2 STORY/35 FT < 2-1/2 STORY/35 FT < 2-1/2 STORY/35 FT EXISTING PARKING REQUIRED AS PER THE SET OF PLANS ENTITLED "AMENDED SITE PLAN PROPOSED ATHLETIC FACILITY, SETON HALL PREPARATORY SCHOOL LOTS 1.01, 1.04, 1.05 & 1.06 BLOCK 81.01; LOTS 1, 7, 7.01, 7.02 & 7.05 BLOCK 82.01; TOWNSHIP OF WEST ORANGE, ESSEX COUNTY, NJ" LOTS 1 & 6 BLOCK 82.02, PREPARED BY GC STEWART ASSOCIATES, INC., LAST REVISED 7/31/14 AND APPROVED BY THE TOWNSHIP OF WEST ORANGE ZONING BOARD ON AUGUST 26, 2014 TH ERE ARE 663 TOTAL PARKING STALLS REQUIRED AND 677 PARKING STALLS PROVIDED. AS SUCH THERE IS A SURPLUS OF 14 PARKING STALLS ON SITE. TOWNSHIP OF WEST ORANGE PARKING REQUIREMENT 4.1, AS PER 25-12.2(b) COMMERCIAL RECREATION, FITNESS CENTER/HEALTH CLUB REQUIRES 1 PARKING STALL PER 150 SQUARE FEET OF GROSS FLOOR AREA PLUS 5 PER EACH OUTDOOR COURT OR FIELD. 11.1, FLOOR AREA OF NEW BUILDING ADDITION PLUS EXISTING BUILDING FOOTPRINT: 6,144 SF 2: 3. TOTAL GROSS FLOOR AREA = 9,015 SF 4. REQUIRES 60 STALLS D, SECOND FLOOR AREA OF NEW BUILDING: 2,871 SF EXISTING 6,630 GROSS SQUARE FOOT KELLY ATHLETIC CENTER TO BE CONVERTED TO STORAGE AS SUCH SITE NEEDS 44 LESS PARKING STALLS ON SITE SINCE NO PARKING IS REQUIRED FOR A STORAGE BUILDING 1.1.6. | NET ADDITIONAL PARKING REQUIRED: 16 PARKING STALLS 1.2, TOTAL PARKING REQUIRED FOR SITE: 679 STALLS PROROSED PARKING REQUIRED THERE ARE TWO (2) PARKING STALLS PROPOSED ADJACENT TO THE EXISTING BUILDING NORTH OF THE EXISTING PRACTICE FIELD AND WEST OF THE EXISTING ATHLETIC FIELD TO MEETING THE TOTAL PARKING S STALLS. STALL REQUIREMENT OF 679 MAXIMUM BUILDING COVERAGE 20% 0.78% 1.03% PARKING REQUIREMENTS OFF-STREET PARKING REQUIREMENTS 679 SPACES (SEE PARKING CALCULATION TABLE) 677 SPACES 679 SPACES OFF-STREET PARKING SETBACK 5 FEET FROM PROPERTY LINE 12h 2.2,Fr* TABLE KEY N/A NOT APPLICABLE * EXISTING NON-CONFORMING VARIANCE REQUIRED APPROVALS e ESSEX COUNTY PLANNING BOARD HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT TOWNSHIP OF WEST ORANGE ZONING BOARD APPROVAL SUBJECT PROPERTY — — = 200! RADIUS ZO) DISTRICT BOUNDARY NORTH ZONING MAP N.T.S. SUBJECT PROPERTY PROJECT DESCRIPTION THE PROJECT PROPOSES TO INSTALL AN ADDITION TO THE EXISTING MAINTENANCE BUILDING TO CREATE A NEW FITNESS CENTER AT

Page 1

) DISTRICT BOUNDARY NORTH ZONING MAP N.T.S. SUBJECT PROPERTY PROJECT DESCRIPTION THE PROJECT PROPOSES TO INSTALL AN ADDITION TO THE EXISTING MAINTENANCE BUILDING TO CREATE A NEW FITNESS CENTER AT 700 PROSPECT AVENUE IN THE TOWNSHIP OF WEST ORANGE NJ. THE MAINTENANCE FUNCTION WILL BE RELOCATED TO THE EXISTING FITNESS BUILDING. IN ADDITION TO THE PROPOSED ADDITION, THE PROJECT WILL REPLACE EXISTING ASPHALT, RELOCATE EXISTING UTILITIES, AND RELOCATE EXISTING STORMWATER DRAINAGE PIPING CONFLICTING WITH THE PROPOSED IMPROVEMENTS. NO SITE LIGHTING OR LANDSCAPING IS PROPOSED AS PART OF THE PROJECT. INDEX OF DRAWINGS DWG. TITLE PREPARED BY SP-100.00 COVER SHEET E2PM SP-101.00 GENERAL NOTES AND MAPPING E2PM SP-101.10 200-FT PROPERTY OWNER'S LIST E2PM SP-102.00 OVERALL EXISTING CONDITIONS PLAN E2PM SP-102.10 EXISTING CONDITIONS AND DEMOLITION PLAN E2PM SP-103.00 OVERALL SITE PLAN E2PM SP-103.10 SITE, GRADING, UTILITY, AND EROSION CONTROL PLAN E2PM SP-110.00 SOIL EROSION AND SEDIMENT CONTROL NOTES & DETAILS E2PM SP-111.00 CONSTRUCTION DETAILS E2PM TOWNSHIP OF WEST ORANGE FOR APPROVAL BY THE TOWNSHIP OF WEST ORANGE: CHAIRMAN OF THE ZONING BOARD DATE SECRETARY OF THE ZONING BOARD DATE TOWNSHIP ENGINEER DATE REVISED PER CME COMMENT LETTER 1, [01/31/2023 DATED 1/20/23 ENS | CJS OWNER SETON HALL PREPARATORY SCHOOL 700 PROSPECT AVENUE TOWNSHIP OF WEST ORANGE, NJ 07052 APPLICANT SETON HALL PREPARATORY SCHOOL 700 PROSPECT AVENUE TOWNSHIP OF WEST ORANGE, NJ 07052 E 2 PROJECT MANAGEMENT LLC Rian aa p2PM cS ROCKAWAY, N.J. 07866 PHONE: (973) 299-5200 FAX: (973) 299-5059 ‘THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY, ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ‘ACT OF 1970 ANO ALL RULES AND REGULATIONS THERETO APPURTENANT. THIS DRAWING AND THE www.E2PM.com [DESIGN FEATURES OR CONSTRUCTION DISCLOSED ARE PROPRIETARY TO E2 PROJECT MANAGEMENT. LLC AND SHALL NOT SE REPRODUCED, ALTERED OR COPIED WITHOUT WRITTEN PERMISSION, SHALL NOT BE USED IN AMY MANNER DETTUMENTAL TO ITS INTEREST AND SHALL BE RETURNED UPON REQUEST, N.J. ENGINEERING CERTIFICATE OF AUTHORIZATION No. 24GA28118200 I CERTIFY THAT THESE PLANS HAVE BEEN PREPARED UNDER MY SUPERVISION As. CHARLES J. STEWART, P.E.,/P.L.S. NJ REGISTERED PROFESSIONAL ENGINEER LICENSE AND NJ PROFESSIONAL LAND SURVEYOR LICENSE NO. 24GB035884 PROJECT

Page 1

THESE PLANS HAVE BEEN PREPARED UNDER MY SUPERVISION As. CHARLES J. STEWART, P.E.,/P.L.S. NJ REGISTERED PROFESSIONAL ENGINEER LICENSE AND NJ PROFESSIONAL LAND SURVEYOR LICENSE NO. 24GB035884 PROJECT NAME SETON HALL PREPARATORY SCHOOL HEALTH AND FITNESS CENTER KELLY ATHLETIC CENTER 700 PROSPECT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY TAX BLOCK 82.01, LOT 1 DRAWING TITLE COVER SHEET CHECKED BY: cis DRAWN BY: ENS SCALE: AS SHOWN SHEET NO: FIRST ISSUE: 10/13/2022 PROJECT #: P-22-34-01 DRAWING NO. SP-100.00