Show all pages512-516 Pleasant Valley Way, West Orange 1240815-pipes Water Quality Storm Water Quality Rainfall=1.25", P2=3.47" Prepared by Casey & Keller, Inc Printed 8/25/2025 HydroCAD® 10.20-7a_s/n 03272 © 2025 HydroCAD Software Solutions LLC Page 44 Summary for Subcatchment 2: Parking Lot Runoff = 0.47 cfs@ 1.07 hrs, Volume= 0.013 af, Depth= 0.95" Routed to Pond 3 : Pervious Pavers Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 0.05 Water Quality Storm Water Quality Rainfall=1.25", P2=3.47" Area (sf) CN Description 6,682 98 Paved parking, HSG C 623 74 _>75% Grass cover, Good, HSG C 7,305 96 Weighted Average 623 74 8.53% Pervious Area 6,682 98 91.47% Impervious Area Te Length Slope Velocity Capacity Description (min) _(feet) (f/ft) _(f/sec) (cfs) 0.1 8 0.0650 1.38 Sheet Flow, 1 Smooth surfaces n=0.011 P2= 3.47" 0.1 15 0.6700 3.99 Sheet Flow, 2 Smooth surfaces n=0.011 P2= 3.47" 0.5 59 0.0500 1.86 Sheet Flow, 3 Smooth surfaces n=0.011 P2= 3.47" 0.2 10 0.0250 0.99 Sheet Flow, 4 Smooth surfaces n= 0.011 _P2= 3.47" 0.9 92 Total 51