PLEASANT VALLEY WAY 1240815-pipes NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Prepared by Casey & Keller, Inc Printed 9/12/2025 HydroCAD® 10.20-7a s/n 03272 © 2025 HydroCAD Software Solutions LLC Summary for Subcatchment 2: Parking Lot Runoff = 0.57 cfs @ 12.06 hrs, Volume= 0.042 af, Depth= 3.01" Routed to Pond 3 : Pervious Pavers Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 0.05 NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Area (sf) CN Description 6,473 98 Paved parking, HSG C 832 74 >75% Grass cover, Good, HSG C 7,305 95 Weighted Average 832 74 11.39% Pervious Area 6,473 98 88.61% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 0.1 8 0.0650 1.38 Sheet Flow, 1 Smooth surfaces n= 0.011 P2= 3.47" 0.1 15 0.6700 3.99 Sheet Flow, 2 Smooth surfaces n= 0.011 P2= 3.47" 0.5 59 0.0500 1.86 Sheet Flow, 3 Smooth surfaces n= 0.011 P2= 3.47" 0.2 10 0.0250 0.99 Sheet Flow, 4 Smooth surfaces n= 0.011 P2= 3.47" 0.9 92 Total 12