Page 26

STORAGE VWC VINYL WALL COVERING 22.CABLE/PHONE BOXES TO GWB. CAB CABINET E EAST GR GRADING MARB MARBLE PR PAIR STRUCT STRUCTURAL K. THE FOLLOWING ITEMS SHALL BE CAULKED, GASKETED, OR OTHERWISE ACOUSTICALLY CAV CAVITY EF EACH FACE GRTG GRATING MAS MASONRY PRCST PRECAST STRUCT STLSTRUCTURAL STEEL TREATED, WHERE OCCURRING AT DWELLING UNIT SEPARATION WALLS, CORRIDOR WALLS, AIR SEALING MATERIALS - USE A COMBINATION OF THE FOLLOWING: CB CATCH BASIN EJ EXPANSION JOINT GYP GYPSUM MATL MATERIAL PREFAB PREFABRICATED SUPPL SUPPLEMENT AND FLOOR/CEILING ASSEMBLIES. 1. CAULK - SEALS GAPS LESS THAN 1/2" WIDE. ARCHITECT'S SEAL: 2. SPRAY FOAM - FILLS LARGE GAPS AND SMALL HOLES. 1. STAGGER AND OVERLAP JOINTS IN MULTI-LAYER GWB WALLS AND CEILINGS. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 2. PROVIDE 1/4" SEALANT JOINT AT GWB TO SUBFLOOR AND CEILING AT DWELLING UNIT 4. GASKETS. SEPARATION WALLS. 5. BUILDING WRAP - INSTALLED OVER EXTERIOR SHEATHING, SEALED WITH TAPE AT LAP 3. PROVIDE

Page 26

4. GASKETS. SEPARATION WALLS. 5. BUILDING WRAP - INSTALLED OVER EXTERIOR SHEATHING, SEALED WITH TAPE AT LAP 3. PROVIDE 1/4" SEALANT JOINT AT GWB TO SUBFLOOR AND CEILING AT CORRIDOR WALLS. JOINTS. 6. SHEET GOODS - WOOD SHEATHING, GYPSUM WALL BOARD AND RIGID FOAM INSULATION REFERENCE SYMBOLS 4. PROVIDE 1/4" SEALANT JOINT AT DOOR FRAMES TO GWB AT CORRIDOR WALLS. WITH EDGES TAPED OR CAULKED. 5. PROVIDE FLEXIBLE GASKET (SMOKE SEAL) AT DOORS IN CORRIDOR WALLS. 7. SHEET METAL - EDGES CAULKED. 6. PROVIDE SEAL AT BOTTOM OF DOORS IN CORRIDOR WALLS. NO. DETAIL SECTION REFERENCE NO. BUILDING DOOR INDICATOR 8. POLYETHYLENE PLASTIC - EDGES AND PENETRATIONS TAPED AND SEALED. 7. ELECTRICAL SERVICE PANEL SHOULD NOT BE LOCATED ON DWELLING UNIT 9. WEATHERSTRIPPING - USED TO SEAL MOVEABLE COMPONENTS SUCH AS DOORS, SHT. SEPARATION OR CORRIDOR WALLS. WINDOWS AND ATTIC ACCESS. XX UNIT DOOR INDICATOR 8. SEAL EXHAUST VENTILATION DUCT JOINTS AND

Page 26

XX UNIT DOOR INDICATOR 8. SEAL EXHAUST VENTILATION DUCT JOINTS AND SEAMS WITH MASTIC. 10.MASTIC - SEALS AIR HANDLERS AND AIR DISTRIBUTION DUCT CONNECTIONS AND JOINTS. XX 9. SEAL WIRING PENETRATIONS THROUGH TOP AND BOTTOM PLATES OF STUD WALLS. 11.UL181 OR FOIL FACED TAPE - PROVIDES TEMPORARY SEAL ON AIR HANDLER AND DUCTS- 10. SEAL ELECTRICAL/CABLE/PHONE BOXES TO GWB WITH PUTTY PADS OR APPROVED NOT ACCEPTABLE. NO. DETAIL / ENLARGED PLAN REFERENCE EQUAL. PROGRESS DATE: 29-01-2026 SHT. NO. WINDOW / STOREFRONT TYPE 11. SEAL WIRING INTO ELECTRICAL BOXES. INDICATOR 12. SEAL RECESSED

Page 26

INDICATOR 12. SEAL RECESSED LIGHT HOUSING TO GWB. 13. PROVIDE FIRE RESISTANCE RATED COVER AROUND RECESSED LIGHTING HOUSING. JM 14. SEAL PLUMBING PIPES AND VENTS THROUGH TOP AND BOTTOM PLATES OF STUD NO. FIN. FLOOR PRINCIPAL IN CHARGE WALLS. EXTERIOR ELEVATION REFERENCE EL. 0'-0" ELEVATION / DATUM 15. SEAL PLUMBING PIPE PENETRATIONS THROUGH GWB. SHT. CC RATED WALL MARKING - IBC 703.7

Page 26

PROJECT TEAM 16. PROVIDE GYPSUM BASED UNDERLAYMENT BENEATH TUBS AND SHOWERS. 17. SEAL TUB AND SHOWER DRAINS TO SUBFLOOR. EL. 0'-0" JM ELEVATION / DATUM 18. SEAL TUB AND SHOWER ENCLOSURE TO SUBFLOOR AND WALL. NO CHECKED BY 19. SEAL SHOWER HEAD TO TILE OR SHOWER SURROUND. - WHERE THIS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACE, FIRE WALLS, FIRE BARRIERS, SHEET DESCRIPTION 20. PROVIDE SEALANT AT FIRE SPRINKLER HEAD ESCUTCHEONS TO GWB. FIRE PARTITIONS SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE

Page 26

20. PROVIDE SEALANT AT FIRE SPRINKLER HEAD ESCUTCHEONS TO GWB. FIRE PARTITIONS SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE NO NO INTERIOR ELEVATION REFERENCE FLOOR ELEVATION CHANGE LEGEND SHEET 21. SEAL ATTIC AND CRAWLSPACE ACCESS COVERS TO GWB OR SUBFLOOR. SHT. PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR 22. SEAL RECESSED HEATERS (PTACS) TO GWB. STENCILING IN THE CONCEALED SPACE. 23. INSULATE DUCTWORK LOCATED WITHIN FLOOR/CEILING ASSEMBLIES. - TEXT TO BE LOCATED A MAXIMUM OF FIFTEEN FEET FROM THE END OF THE WALL AND AT INTERVALS NOT TO NO 24. SEAL HVAC AND VENTILATION GRILLES, INLETS AND DIFFUSERS TO GWB. EXCEED THIRTY FEET. 25. SEAL KITCHEN AND BATH EXHAUST FAN HOUSING TO GWB. ABCDE WALL TYPE INDICATOR

Page 26

ABCDE WALL TYPE INDICATOR ISSUED FOR: No. Date Description 26. SEAL CLOTHES WASHER VALVE/DRAIN BOX TO GWB. FLOOR/CEILING ASSEMBLY Z# # (SEE PARITION TYPE SHEET) 27. SEAL CLOTHES DRYER EXHAUST BOX SEALED TO GWB. NO. NO. BUILDING SECTION REFERENCE 28. SEAL BUILT-IN CABINETS TO GWB. SHT. SHT. 29. FASTEN CEILING MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT CEILING. ACCESSIBLE CONCEALED AREA

Page 26

ACCESSIBLE CONCEALED AREA XX OF FLOOR/CEILING ASSEMBLY FLOOR / CEILING OR ROOF / CEILING 30. FASTEN WALL BASE MOLDING TO WALL ONLY. PROVIDE SEALANT JOINT AT FLOOR XX FIRE AND/OR SMOKE FIRE AND/OR SMOKE TYPE INDICATOR LINE. BARRIER - PROTECT BARRIER - PROTECT 31. PROVIDE VIBRATION ISOLATION OF THE OVERHEAD GARAGE DOOR TRACKS. ALL OPENINGS ALL OPENINGS NO. WALL SECTION REFERENCE 32. PROVIDE VIBRATION ISOLATION OF THE GARAGE DOOR OPENER WITH RESILIENT SHT. MOUNTING HARDWARE. 15' MAX.

Page 26

SHT. MOUNTING HARDWARE. 15' MAX. 30' MAX. 1 KEYNOTE INDICATOR ACOUSTICAL CEILING OR A0.01A N. SOUND CONTROL MATERIALS - USE A COMBINATION OF THE FOLLOWING: OTHERWISE ACCESSIBLE ROOM NAME CEILING SYSTEM ROOM INDICATOR 1 REVISION INDICATOR 1. NON-HARDENING CAULK - SEALS GAPS LESS THAN 1/2" WIDE. NO. 2. SPRAY FOAM - FILLS LARGE GAPS AND SMALL HOLES. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 4. GASKETS - NEOPRENE, RUBBER, FOAM.

Page 26

APS AND SMALL HOLES. 3. BACKER ROD - CLOSED CELL FOAM OR ROPE CAULK PRESSED INTO GAPS. 4. GASKETS - NEOPRENE, RUBBER, FOAM. UNIT TYPE FIRE WALL, FIRE BARRIER, FIRE UNIT INDICATOR 5. ACOUSTICAL SOUND MAT MEMBRANE. NO. SHEET NUMBER 6. GYPSUM BASED UNDERLAYMENT AT WOOD SUB-FLOORS. PARTITION, SMOKE BARRIER EXAMPLE OF CONCEALED CEILING SPACE 7. SOUND CONTROL MAT BENEATH HARD FLOOR SURFACES. OR SMOKE PARTITION 8. RESILIENT CHANNELS - DIETRICH RC DELUXE RCSD 9. SOUND ISOLATION CLIPS USED WITH METAL FURRING CHANNELS. 3" HIGH, MIN. 10. GYPSUM WALL BOARD.