CONSULTANTS, INC. Tel: (800) 545-ATUL A N 4405 South Clinton Avenue (908) 754-8383 South Plainfield, NJ 07080 Fax: (908) 754-8633 NJ EDA Approved Testing Laboratory * MBE/DBE Certified * NJ DEP Certified www.ANSConsultants.net Soil, Concrete, Masonry, Rebar, Asphalt, Structural Steel, Precast, Piles, Caissons, Fire-proofing, Roofing, Soil Boring, Concrete/Rock Coring, UST Removal, Environmental Testing & Reports 06/05/2025 CLIENT : Hudson Engineering DATE: 437 Palisade Avenue Passaic, NJ FILE NO. : AOF-6133 Attn. : Mr. Jorden Cecinini PROJECT: JMA02P003 REPORT No.: 01 262 Main Street West Orange, NJ TEST REQUIRED: Unconfined Compression Strength of intact Rock Core AS PER ASTM D 2938 DATE RECEIVED: 06/03/2025 DATE TESTED : 06/05/2025 IDENTIFICATION REMARKS : 1. Compressive strength of one (1) core was 8,620 psi. 2. Density of Rock core (unit weight) was 158.15 Ib./ft®. 3. Compression testing machine of 500,000 Ib. Capacity, manufactured by Test Mark Industries, Sr No. 10897, Mode! # CM-5090 EBS (Extended Frame) was utilized for testing cores. “ANSwers to your construction inspection and testing needs.” {An equal opportunity employer