Page 9

PAGE | 9 high water table elevation and permeability rate of the subsoils on-site to demonstrate compliance with the applicable BMP design requirements. 8. The “Typical Permeable Pavement Detail” on sheet C1.07 of the site plans must be revised to remove the discrepancy of the maximum slope of the surface course. 9. Sheet C1.07 of the site plans must be revised to show all existing and proposed stormwater piping including the stormwater outlet pipes from the proposed stormwater management systems to the ultimate discharge point(s). 10. Sheet C1.07 of the site plans must be revised to call out the invert elevations of the trench drains. 11. Sheet C1.08 of the site plans include details of inlet protection, a Draintech outlet, and a clean out, yet these improvements are not called out on the plan views. This discrepancy must be resolved. 12. The “Rain Garden Cross-Section” detail on Sheet C1.08 of the site plans includes underground piping. A layout of this piping should be shown on the plan views. 13. The “Rain Garden Cross-Section” detail on Sheet C1.08 of the site plans should be revised as the detail and the notes do not correspond to the geometry and likeness of the rain gardens shown in the plan views. 14. The specification of the “Rain Garden Cross-Section” on Sheet C1.08 should be revised to ensure the bioretention media layer meets the standards set forth in Chapter 9.7 of the NJ Stormwater BMP Manual. E. LANDSCAPING COMMENTS 1. In accordance with §25-11.3b of the Ordinance, along any side or rear property line which is also the boundary line between a nonresidential district and a residential district or is contiguous to a residential use in a residential zone, a buffer strip shall be planted and maintained in perpetuity with trees and shrubbery of such sizes and densities as to adequately screen the buildings from such abutting residential district or use in a residential zone. On smaller lots, the required buffer width shall be 10% of lot width or depth, but not less than 20 feet. Whereas, the Applicant has not proposed buffering along the existing dwellings surrounding the site. 2. The Plant Schedule should be revised to include, but not limited to, botanical names, quantities and installation sizes, graphics and labels, etc., for further review. All proposed plants on-site and within the proposed rain gardens should be in the plant schedule. 3.

Page 9

botanical names, quantities and installation sizes, graphics and labels, etc., for further review. All proposed plants on-site and within the proposed rain gardens should be in the plant schedule. 3. In accordance with §25-12.1e, any parking area shall be screened on any side which adjoins or faces premises situated in any residence district by a fence, wall, berm, evergreen or hedge. The Applicant should provide testimony to the Board regarding whether the proposed retaining wall will sufficiently screen adjoining Lot 51.

File revisions (1)