Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · May 6, 2026

Report 4 13 2026

Preserved file SHA-256e043d495fcedc3c9f69247133d4a66bb2eba4dd398622fa176b144b0e20391d8

Indexed text · page 20

Show all pages
Page 20

Form 3b. Tube Permeameter Test Data: Blk. 158, Prop. Lot 28.03 W. Orange (Dry Well) 1. Test Number__Log -4_ Replicate (letter) A Date Collected 03/20/2025 2. Material Tested: Test in Native Soil — Indicate Depth_80” 3. Type of Sample:__X__ Undisturbed Disturbed 4. Sample Dimensions: Inside Radius of Sample Tube, R, in inches _ 1.88” Length of Sample, L, in inches 3.5” 5. Bulk Density Determination: 6. Standpipe used: No Xx Yes Indicate Internal Radius, __ 0.44” 7. Height of Water Level Above Rim of Test Basin, in inches: At the Beginning of Each Test Interval, H;__7.0” At the End of Each Test Interval, H,__ 6.0” 8. Rate of Water Level Drop: *““"*S TOPWATCH USED Length of Test Interval, T in Minutes (decimal) 5.60min./inch 5.62min./inch 5.62min./inch 5.63min./inch 5.63min./inch 5.63min./inch 9. Calculation of Permeability: K, (in/hr) = 60 min/hr x 7/R? x L(in)/T(min) x In(Hy/H2) = (60 min/hr x 0.194/3.534) x__ 3.5" /__ 5.63 x In (7.0/6.0 ) = _0.32 in/hr = K-1 10. Defects in the Sample: None Control Act (N.J.S.A. 58:10A-1 et sex NJAC. : 7:14-8. Signature of Soil Evaluator Lox Date _ 03/21/2026 -E., License No. 44863 Signature of Professional Engineer William S. Scott,