Show all pages1017 Greeley Ave N Union, NJ 07083 908-964-0786 www.RSAGeolab.com Tube Permeameter Test Client: Langan Eng. & Env. Services, Inc. Job No.: 869 Project: Eagle Rock Ave Widening Project Lab Log No.: L#25-4128 Proj. No. 101049802 Sample: TP-16, ST-1, 2.5' Date: 4/29/2025 Average Length of Soil Core 3.976 in. Initial Weight of Soil Core 832.9 grams Final Weight of Soil Core 847.8 grams Dry Weight of Soil Core 716.1 grams Diameter of Shelby Tube 2.875 in. Initial Moisture Content 16.31% Diameter of Standpipe 0.250 in. Final Moisture Content 18.39% Wet Density, Initial 122.94 PCF Wet Density, Final 125.14 PCF Dry Density 105.69 PCF Initial Height Final Height Change in Water Level Time Interval Hydraulic Conductivity Trial No. (inches) (inches) (inches) (secs) cm/sec in/hr 1 39.2 38.2 1.0 240.0 8.22E-06 1.17E-02
cm/sec in/hr 1 39.2 38.2 1.0 240.0 8.22E-06 1.17E-02 2 38.2 37.0 1.2 290.0 8.40E-06 1.19E-02 3 37.0 35.9 1.1 275.0 8.38E-06 1.19E-02 Average Hydraulic Conductivity 8.34E-06 cm/sec 1.18E-02 in/hr Remarks: 1. Test Conducted Using Daired Tap Water at Standard Temp. (72° F) 2. 100% Saturation Assumed Tested by: SP Checked by: KP