Supporting Documentation · Jun 3, 2026
2026 02 12 Crestmont CC and Eagle Rock Ave Stormwater Management Report
b2e79b7061cbbbe57e9837f2fec3a1c0d102ba104a1fd5bfe1ade5107afe3de3Indexed text · page 963
Show all pages1017 Greeley Ave N Union, NJ 07083 908-964-0786 www.RSAGeolab.com Shelby Tybe Hydraulic Conductivity Test ASTM D2434 (For Calculations) Client: Langan Eng. & Env. Services, Inc. Job No.: 869 Project: Eagle Rock Ave Widening Project Lab Log No.: L#24-3391 Proj. No. 101049801 Sample: TP-7 S-1 8"-18" Date: 5/24/2024 Average Length of Soil Core 3.746 in. Initial Weight of Soil Core 782.1 grams Final Weight of Soil Core 802.4 grams Dry Weight of Soil Core 670.1 grams Diameter of Shelby Tube 2.875 in. Initial Moisture Content 16.72% Diameter of Standpipe 0.250 in. Final Moisture Content 19.75% Wet Density, Initial 122.52 PCF Wet Density, Final 125.69 PCF Dry Density 104.97 PCF Initial Height Final Height Change in Water Level Time Interval Hydraulic Conductivity Trial No. (inches) (inches) (inches) (secs) cm/sec in/hr 1 39.6
(inches) (secs) cm/sec in/hr 1 39.6 35.0 4.6 520.0 1.71E-05 2.42E-02 2 35.0 31.0 4.0 490.0 1.78E-05 2.53E-02 3 31.0 27.2 3.8 505.0 1.86E-05 2.64E-02 Average Hydraulic Conductivity 1.78E-05 cm/sec 2.53E-02 in/hr Remarks: 1. Test Conducted Using Daired Tap Water at Standard Temp. (72° F) 2. 100% Saturation Assumed Tested by: AO Checked by: KP
File revisions (1)
- Sep 29, 2026
b2e79b7061cb295,885,934 bytes