Supporting Documentation · Jun 3, 2026
2026 02 12 Crestmont CC and Eagle Rock Ave Stormwater Management Report
b2e79b7061cbbbe57e9837f2fec3a1c0d102ba104a1fd5bfe1ade5107afe3de3Indexed text · page 991
Show all pages1017 Greeley Ave N Union, NJ 07083 908-964-0786 www.RSAGeolab.com Tube Permeameter Test Client: Langan Eng. & Env. Services, Inc. Job No.: 869 Project: Eagle Rock Ave Widening Project Lab Log No.: L#25-4128 Proj. No. 101049802 Sample: TP-20, ST-1, 1.5' Date: 4/29/2025 Average Length of Soil Core 5.692 in. Initial Weight of Soil Core 1177.8 grams Final Weight of Soil Core 1185.4 grams Dry Weight of Soil Core 988.6 grams Diameter of Shelby Tube 2.875 in. Initial Moisture Content 19.13% Diameter of Standpipe 0.250 in. Final Moisture Content 19.91% Wet Density, Initial 121.43 PCF Wet Density, Final 122.22 PCF Dry Density 101.93 PCF Initial Height Final Height Change in Water Level Time Interval Hydraulic Conductivity Trial No. (inches) (inches) (inches) (secs) cm/sec in/hr 1 39.9 38.4 1.5 720.0 5.82E-06 8.25E-03
cm/sec in/hr 1 39.9 38.4 1.5 720.0 5.82E-06 8.25E-03 2 38.4 37.0 1.4 710.0 5.72E-06 8.10E-03 3 37.0 35.7 1.3 695.0 5.63E-06 7.97E-03 Average Hydraulic Conductivity 5.72E-06 cm/sec 8.11E-03 in/hr Remarks: 1. Test Conducted Using Daired Tap Water at Standard Temp. (72° F) 2. 100% Saturation Assumed Tested by: SP Checked by: KP
File revisions (1)
- Sep 29, 2026
b2e79b7061cb295,885,934 bytes